Difference between revisions of "Dry Etching Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(smaller fonts to make table more obvious)
m (corrected links)
 
(9 intermediate revisions by 2 users not shown)
Line 4: Line 4:
 
===Dry Etching Tools/Materials Table===
 
===Dry Etching Tools/Materials Table===
   
* <small>'''R''': ''Recipe is available. Clicking this link will take you to the recipe.''</small>
+
*<small>'''R''': ''Recipe is available. Clicking this link will take you to the recipe.''</small>
* <small>'''A''': ''Material is available for use, but no recipes are provided.''</small>
+
*<small>'''A''': ''Material is available for use, but no recipes are provided.''</small>
   
 
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1"
 
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1"
  +
|-
  +
! colspan="17" width="725" height="45" |<div style="font-size: 150%;">Dry Etching Recipes</div>
 
|- bgcolor="#d0e7ff"
 
|- bgcolor="#d0e7ff"
  +
| bgcolor="#eaecf0" |<!-- INTENTIONALLY LEFT BLANK -->
! colspan="18" width="725" height="45" |<div style="font-size: 150%;">Dry Etching Recipes</div>
 
|- bgcolor="#d0e7ff"
 
|<!-- INTENTIONALLY LEFT BLANK -->
 
 
! colspan="3" |'''[[RIE Etching Recipes|RIE Etching]]'''
 
! colspan="3" |'''[[RIE Etching Recipes|RIE Etching]]'''
 
! colspan="6" |'''[[ICP Etching Recipes|ICP Etching]]'''
 
! colspan="6" |'''[[ICP Etching Recipes|ICP Etching]]'''
! colspan="5" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
+
! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
 
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]'''
 
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]'''
  +
|- bgcolor="#d0e7ff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |'''Material'''
 
! bgcolor="#d0e7ff" align="center" |'''Material'''
 
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]]
 
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]]
Line 23: Line 23:
 
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
 
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
 
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]]
 
| bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]]
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_1_.28Panasonic_E626I.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E626I)</span>]]
+
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 1 .28Panasonic E646V.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E646V)</span>]]
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_2_.28Panasonic_E640.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]]
+
| bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E626I)</span>]]
 
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]]
 
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]]
 
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]]
 
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]]
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br><span style="font-size: 88%;">(Gasonics 2000)</span>]]
 
 
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]]
 
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]
Line 37: Line 36:
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |Ag
 
! bgcolor="#d0e7ff" align="center" |Ag
|
 
 
|
 
|
 
|
 
|
Line 63: Line 61:
 
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 2)}}
 
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 2)}}
|
 
 
|
 
|
 
|
 
|
Line 75: Line 72:
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |Au
 
! bgcolor="#d0e7ff" align="center" |Au
|
 
 
|
 
|
 
|
 
|
Line 101: Line 97:
 
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}}
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 113: Line 108:
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |Cu
 
! bgcolor="#d0e7ff" align="center" |Cu
|
 
 
|
 
|
 
|
 
|
Line 139: Line 133:
 
|A
 
|A
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 151: Line 144:
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |Mo
 
! bgcolor="#d0e7ff" align="center" |Mo
|
 
 
|
 
|
 
|
 
|
Line 177: Line 169:
 
|A
 
|A
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 189: Line 180:
 
|- bgcolor="#ffffff"
 
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |Ni
 
! bgcolor="#d0e7ff" align="center" |Ni
|
 
 
|
 
|
 
|
 
|
Line 215: Line 205:
 
|A
 
|A
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 227: Line 216:
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |Pt
 
! bgcolor="#d0e7ff" align="center" |Pt
|
 
 
|
 
|
 
|
 
|
Line 253: Line 241:
 
|A
 
|A
 
|{{Rl|ICP Etching Recipes|Ru (Ruthenium) Etch (Panasonic 2)}}
 
|{{Rl|ICP Etching Recipes|Ru (Ruthenium) Etch (Panasonic 2)}}
|
 
 
|
 
|
 
|
 
|
Line 269: Line 256:
 
|
 
|
 
|{{rl|ICP Etching Recipes|DSEIII_(PlasmaTherm/Deep_Silicon_Etcher)}}
 
|{{rl|ICP Etching Recipes|DSEIII_(PlasmaTherm/Deep_Silicon_Etcher)}}
|{{Rl|ICP Etching Recipes|Si Etching}}
+
|{{Rl|ICP Etching Recipes|Si_Etching_.28Fluorine_ICP_Etcher.29}}
 
|
 
|
 
|
 
|
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 291: Line 277:
 
|A
 
|A
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 310: Line 295:
 
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}}
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 327: Line 311:
 
|
 
|
 
|
 
|
|
+
|A
 
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R]
 
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R]
|
 
 
|
 
|
 
|
 
|
Line 348: Line 331:
 
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}}
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 365: Line 347:
 
|
 
|
 
|
 
|
|{{rl|ICP Etching Recipes|AlGaAs Etch (Panasonic 1)}}
+
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}}
 
|
 
|
 
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]]
 
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]]
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}}
|
 
 
|
 
|
 
|
 
|
Line 388: Line 369:
 
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]]
 
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]]
 
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
|
 
 
|
 
|
 
|
 
|
Line 409: Line 389:
 
|
 
|
 
|
 
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|-
  +
!BCB
 
|
 
|
 
|
 
|
Line 415: Line 402:
 
|
 
|
 
|A
 
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |CdZnTe
 
! bgcolor="#d0e7ff" align="center" |CdZnTe
 
|{{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}}
 
|{{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}}
|
 
 
|
 
|
 
|
 
|
Line 441: Line 437:
 
|
 
|
 
|
 
|
|{{rl|ICP Etching Recipes|GaAs-AlGaAs_Etch_.28Panasonic_1.29}}
+
|{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|GaAs Etch (Panasonic 2)}}
 
|{{rl|ICP Etching Recipes|GaAs Etch (Panasonic 2)}}
 
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]]
 
|[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]]
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}}
|
 
 
|
 
|
 
|
 
|
Line 464: Line 459:
 
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]]
 
|[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]]
 
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
|
 
 
|
 
|
 
|
 
|
Line 474: Line 468:
 
|- bgcolor="#ffffff"
 
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |GaSb
 
! bgcolor="#d0e7ff" align="center" |GaSb
|
 
 
|
 
|
 
|
 
|
Line 481: Line 474:
 
|
 
|
 
|A
 
|A
|
+
|A
  +
|A
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}}
|
 
 
|
 
|
 
|
 
|
Line 493: Line 486:
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub>
 
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub>
|
 
 
|
 
|
 
|
 
|
Line 521: Line 513:
 
|A
 
|A
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
|
 
 
|
 
|
 
|
 
|
Line 540: Line 531:
 
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]]
 
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]]
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
|
 
 
|
 
|
 
|
 
|
Line 559: Line 549:
 
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]]
 
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]]
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
|
 
 
|
 
|
 
|
 
|
Line 570: Line 559:
 
! bgcolor="#d0e7ff" align="center" |ITO
 
! bgcolor="#d0e7ff" align="center" |ITO
 
|{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}}
 
|{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}}
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|-
  +
!LiNbO3
 
|
 
|
 
|
 
|
Line 598: Line 604:
 
|
 
|
 
|
 
|
  +
|[[Oxygen Plasma System Recipes#O2 Ashing|R]]
|A
 
  +
|[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|R]]
|A
 
|A
 
 
|
 
|
 
|
 
|
Line 615: Line 620:
 
|A
 
|A
 
|[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R]]
 
|[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R]]
|
 
 
|
 
|
 
|
 
|
Line 634: Line 638:
 
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}}
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 650: Line 653:
 
|
 
|
 
|
 
|
  +
|[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29|R]]
|A
 
 
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 2)}}
 
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 2)}}
Line 656: Line 659:
 
|
 
|
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 672: Line 674:
 
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 2)}}
 
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 2)}}
|
 
 
|
 
|
 
|
 
|
Line 695: Line 696:
 
|
 
|
 
|
 
|
  +
|
  +
|
  +
|
  +
|
  +
|A
  +
|-
  +
!SU8
 
|
 
|
 
|
 
|
Line 701: Line 709:
 
|
 
|
 
|A
 
|A
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
  +
|
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub>
 
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub>
Line 708: Line 726:
 
|
 
|
 
|
 
|
|
+
|A
 
|[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 A]
 
|[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 A]
|
 
 
|
 
|
 
|
 
|
Line 722: Line 739:
 
|- bgcolor="#ffffff"
 
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |TiN
 
! bgcolor="#d0e7ff" align="center" |TiN
|
 
 
|
 
|
 
|
 
|
Line 741: Line 757:
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub>
 
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub>
|
 
 
|
 
|
 
|
 
|
Line 767: Line 782:
 
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}}
 
|A
 
|A
|
 
 
|
 
|
 
|
 
|
Line 779: Line 793:
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
 
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub>
 
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub>
|
 
 
|
 
|
 
|
 
|
Line 799: Line 812:
 
! bgcolor="#d0e7ff" align="center" |ZnS
 
! bgcolor="#d0e7ff" align="center" |ZnS
 
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
 
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
|
 
 
|
 
|
 
|
 
|
Line 818: Line 830:
 
! bgcolor="#d0e7ff" align="center" |ZnSe
 
! bgcolor="#d0e7ff" align="center" |ZnSe
 
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
 
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
|
 
 
|
 
|
 
|
 
|
Line 836: Line 847:
 
|- bgcolor="#ffffff"
 
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub>
 
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub>
|
 
 
|
 
|
 
|
 
|
Line 865: Line 875:
 
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]]
 
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]]
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br><span style="font-size: 88%;">(Gasonics 2000)</span>]]
 
 
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]]
 
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]

Latest revision as of 15:31, 7 February 2024

Process Control Data

See linked page for process control data (dep rate/stress etc. over time), for a selection of often-used thin-film depositions.

Dry Etching Tools/Materials Table

  • R: Recipe is available. Clicking this link will take you to the recipe.
  • A: Material is available for use, but no recipes are provided.
Dry Etching Recipes
RIE Etching ICP Etching Oxygen Plasma Systems Other Dry Etchers
Material RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E646V)
ICP Etch 2
(Panasonic E626I)
Oxford ICP (PlasmaPro 100) ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)
Ag A
Al A R R A
Au R
Cr A R A A
Cu A
Ge A A A A
Mo A
Nb A A
Ni R
Os A A
Pt R
Ru A R A
Si R R A R A
Ta A A A
Ti R A A
Al2O3 A R A
Al2O3 (Sapphire) R A A
AlGaAs R R R R A
AlGaN R R A
AlN R A
BCB A
CdZnTe R A
GaAs R R R R R A
GaN R R A R R A
GaSb A A A R A
HfO2 A
InGaAlAs R A R A
InGaAsP R R R A
InP R A A R R R
ITO R A
LiNbO3 A
Photoresist

& ARC

A R R R R R R A
Ru A R
SiC R A A
SiN R R R R A A
SiO2 R R R R R A
SiOxNy A A A
SU8 A
Ta2O5 A A A
TiN A
TiO2 A
W-TiW R A A
ZnO2 A
ZnS R A
ZnSe R A
ZrO2 A
Material RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
Oxford ICP (PlasmaPro 100) ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)