Difference between revisions of "Stepper 3 (ASML DUV)"
Jump to navigation
Jump to search
(Created page with "{{tool|{{PAGENAME}} |picture=ASML.jpg |type = Vacuum Deposition |super= Adam Abrahamsen |phone=(805)839-3918x213 |location=Bay 3 |email=abrahamsen@ece.ucsb.edu |description = ASM…") |
|||
Line 1: | Line 1: | ||
{{tool|{{PAGENAME}} |
{{tool|{{PAGENAME}} |
||
|picture=ASML.jpg |
|picture=ASML.jpg |
||
− | |type = |
+ | |type = Lithography |
|super= Adam Abrahamsen |
|super= Adam Abrahamsen |
||
|phone=(805)839-3918x213 |
|phone=(805)839-3918x213 |
Revision as of 17:52, 27 June 2012
|
About
The ASML DUV stepper is a 248nm line stepper for imaging dense features down to below 200nm and isolated line structures down to below 150nm. The system is a variable NA system and has a field image size of 21 x 21mm for 0.63 NA and a field size of 22mm x 27mm for 0.4 to 0.57NA. Overlay accuracy is better than 30nm. The system is configured for 4” wafers and pieces down to 14mm in size can be exposed using a 4” wafer as a carrier.