{{tool2|{{PAGENAME}}
 
|picture=CDEResmap.jpg
 
|picture=CDEResmap.jpg
 
|type = Inspection, Test and Characterization
 
|type = Inspection, Test and Characterization
|super= Tony Bosch
+
|super= Bill Millerski
  +
|super2= Tony Bosch
 
|phone=(805)839-3918x217
 
|phone=(805)839-3918x217
 
|location=Bay ?
 
|location=Bay ?
Line 10: Line 11:
 
|materials =
 
|materials =
 
}}
 
}}
= About =
+
=About=
The CDE Resmap 4 point resistivity mapper is used for measuring resistivity across the wafer for substrates and thin films deposited in the facility. The system can do automated resistivity mapping for pieces to 8 inch wafers. The resistivity range is 2mOhm/Square to 5MOhm/square. Contour plots, 3D plots, histograms, data exporting are supported from the Windows XP based control system.
+
The CDE Resmap 4 point resistivity mapper is used for measuring resistivity across the wafer for substrates and thin films deposited in the facility. The system can do automated resistivity mapping for pieces to 8 inch wafers.
  +
  +
The resistivity range is 2 mOhm/Square to 5 MOhm/square. Contour plots, 3D plots, histograms, data exporting are supported from the Windows XP based control system.
  +
  +
==Instructions==
  +
  +
*[[CDE ResMap Quick-Start instructions]]
  +
*[https://wiki.nanofab.ucsb.edu/w/images/3/37/CDE_ResMap_Operating_Instructions.pdf CDE ResMap Operating Instructions]
  +
*System can export CSV files - contact supervisor for instructions.

Latest revision as of 15:07, 30 October 2023

Resistivity Mapper (CDE RESMAP)
CDEResmap.jpg
Location Bay ?
Tool Type Inspection, Test and Characterization
Manufacturer Creative Design Engineering
Description CDE Resmap 4 Point Resistivity Mapper

Primary Supervisor Bill Millerski
(805) 893-2655
wmillerski@ucsb.edu

Secondary Supervisor

Tony Bosch


Recipes


About

The CDE Resmap 4 point resistivity mapper is used for measuring resistivity across the wafer for substrates and thin films deposited in the facility. The system can do automated resistivity mapping for pieces to 8 inch wafers.

The resistivity range is 2 mOhm/Square to 5 MOhm/square. Contour plots, 3D plots, histograms, data exporting are supported from the Windows XP based control system.

Instructions