Difference between revisions of "Vacuum Deposition Recipes"
Jump to navigation
Jump to search
m (added IBD "A" recipes for all target metals (Si, Ti, Al, Ta).) |
(Delete Sputter1 and 2) |
||
(16 intermediate revisions by 3 users not shown) | |||
Line 2: | Line 2: | ||
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" border="1" |
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" border="1" |
||
|- bgcolor="#d0e7ff" |
|- bgcolor="#d0e7ff" |
||
− | ! colspan=" |
+ | ! colspan="16" width="1675" height="45" |<div style="font-size: 150%;">Vacuum Deposition Recipes</div> |
|- bgcolor="#d0e7ff" |
|- bgcolor="#d0e7ff" |
||
− | | |
+ | |<!-- INTENTIONALLY LEFT BLANK --><br> |
− | ! colspan="4" |
+ | ! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[E-Beam Evaporation Recipes|E-Beam Evaporation]]''' |
− | ! colspan=" |
+ | ! colspan="4" |'''[[Sputtering Recipes|Sputtering]]''' |
− | ! colspan="2" |
+ | ! colspan="2" bgcolor="#d0e7ff" align="center" |'''[[Thermal Evaporation Recipes|Thermal Evaporation]]''' |
− | ! colspan="3" |
+ | ! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[PECVD Recipes|Plasma Enhanced Chemical<br>Vapor Deposition (PECVD)]]''' |
− | ! width="90" |
+ | ! width="90" bgcolor="#d0e7ff" align="center" |'''[[Atomic Layer Deposition Recipes|Atomic Layer Deposition]]''' |
− | ! width="80" |
+ | ! width="80" bgcolor="#d0e7ff" align="center" |'''[[Molecular Vapor Deposition Recipes|Molecular Vapor Deposition]]''' |
|- |
|- |
||
− | ! width="20" |
+ | ! width="20" bgcolor="#d0e7ff" align="center" |'''Material''' |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29|Sputter 3<br>(AJA ATC 2000-F)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(AJA ATC 2200-V)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[https://www.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#Sputter_5_.28AJA_ATC_2200-V.29 Sputter 5 (AJA ATC 2200-V)] |
− | | width=" |
+ | | width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]] |
− | | width=" |
+ | | width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]] |
− | | width=" |
+ | | width="65" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]] |
− | | width=" |
+ | | width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29|Unaxis VLR ICP-PECVD]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAL)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]] |
− | | width="65" bgcolor="#daf1ff" | [[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAL)]] |
||
− | | width="65" bgcolor="#daf1ff" | [[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]] |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ag |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Al |
− | | |
+ | |{{Al/E1}} |
− | | |
+ | |<br> |
− | | |
+ | |{{Al/E3}} |
− | | |
+ | |{{Al/E4}} |
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
− | | |
+ | |{{rl|Sputtering Recipes|Al Deposition (Sputter 4)}} |
+ | |<br> |
||
− | | [[Sputtering Recipes|A]] |
||
+ | |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | [[Sputtering Recipes|R]] |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
+ | |<br> |
||
− | | [[Thermal Evaporation Recipes|A]] |
||
+ | |<br> |
||
− | | [[Thermal Evaporation Recipes|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E2}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Al2O3 Deposition (Sputter 4)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |[https://www.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#Al2O3_deposition_.28IBD.29 R] |
||
− | | bgcolor="#eeffff" | [[Sputtering Recipes|A]] |
||
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|Al2O3 deposition (ALD CHAMBER 3)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | {{rl|Atomic Layer Deposition Recipes|Al2O3 deposition (ALD)}} |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |AlN |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
− | | |
+ | |[[Sputtering Recipes|A]] |
+ | |<br> |
||
− | | [[Sputtering Recipes|A]] |
||
+ | |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | [[Sputtering Recipes|A]] |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |{{rl|Atomic Layer Deposition Recipes|AlN deposition (ALD CHAMBER 3)}} |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | {{rl|Atomic Layer Deposition Recipes|AlN deposition (ALD)}} |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Au |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |B |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |C |
− | | |
+ | | bgcolor="#eeffff" align="center" |{{rl|E-Beam Evaporation Recipes|Materials Table (E-Beam #1)}} |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | |
+ | | bgcolor="#eeffff" align="center" | |
− | | align="center" bgcolor="#eeffff" | |
||
− | | align="center" bgcolor="#eeffff" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |CeO<sub>2</sub> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|E-Beam Evaporation Recipes|E-Beam 2 (Custom)|CeO<sub>2</sub> deposition (E-Beam 2)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Co |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|R]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Cr |
− | | |
+ | |{{Al/E1}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |{{Al/E4}} |
+ | |[https://www.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29 R] |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[Sputtering Recipes|R]] |
||
− | | |
+ | |<br> |
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
+ | |<br> |
||
− | | [[Thermal Evaporation Recipes|A]] |
||
+ | |<br> |
||
− | | [[Thermal Evaporation Recipes|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Cu |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Fe |
− | | |
+ | |{{Al/E1}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |{{Al/E4}} |
+ | |[[Sputtering Recipes|R]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[Sputtering Recipes|R]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ge |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |GeO<sub>2</sub> |
− | | |
+ | | |
− | | |
+ | |{{Al/E2}} |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
||
− | | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Gd |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Hf |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
+ | |<br> |
||
− | | [[Sputtering Recipes|A]] |
||
+ | |<br> |
||
− | | [[Sputtering Recipes|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |{{rl|Atomic Layer Deposition Recipes|HfO2 deposition (ALD CHAMBER 3)}} |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | {{rl|Atomic Layer Deposition Recipes|HfO2 deposition (ALD)}} |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |In |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ir |
− | | |
+ | |{{Al/E1}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |ITO |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|E-Beam Evaporation Recipes|E-Beam 2 (Custom)|ITO deposition (E-Beam 2)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |MgF2 |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
+ | |[[Sputtering Recipes|A]] |
||
− | | |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | |
||
+ | | |
||
− | | [[Sputtering Recipes|A]] |
||
+ | | |
||
− | | [[Sputtering Recipes|A]] |
||
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
||
− | | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |MgO |
− | | |
+ | | |
− | | |
+ | |{{Al/E2}} |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
||
− | | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Mo |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|R]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Nb |
− | | |
+ | |{{Al/E1}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Sputtering Recipes|R]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[Sputtering Recipes|R]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Nd |
− | | |
+ | | |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[Sputtering Recipes|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ni |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |NiCr |
− | | |
+ | |{{Al/E1}} |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | |{{Al/E4}} |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
||
− | | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |NiFe |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" | |
− | | bgcolor="#eeffff" | |
||
− | | bgcolor="#eeffff" | |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Pd |
− | | |
+ | |{{Al/E1}} |
− | | |
+ | |<br> |
− | | |
+ | |{{Al/E3}} |
− | | |
+ | |{{Al/E4}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
+ | |<br> |
||
− | | [[Thermal Evaporation Recipes|A]] |
||
+ | |<br> |
||
− | | [[Thermal Evaporation Recipes|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Pt |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 4 (AJA ATC 2200-V)}} |
+ | | bcolor="EEFFFF" |<br> |
||
− | | bgcolor="#eeffff" | [[Sputtering Recipes|A]] |
||
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|Pt deposition (ALD CHAMBER 1)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | {{rl|Atomic Layer Deposition Recipes|Pt deposition (ALD)}} |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ru |
− | | |
+ | |{{Al/E1}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |{{Al/E4}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |{{rl|Atomic Layer Deposition Recipes|Ru deposition (ALD CHAMBER 1)}} |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Si |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E2}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|R]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |[https://www.nanotech.ucsb.edu/wiki/index.php/PECVD_Recipes#Amorphous-Si_deposition_.28PECVD_.232.29 R] |
||
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[PECVD_Recipes#Amorphous_Si_.28100.25SiH4_Ar_He.29|R]] |
+ | | bgcolor="#eeffff" |<br> |
||
− | | bgcolor="#eeffff" | {{rl|PECVD Recipes|PECVD 2 (Advanced Vacuum)|Amorphous-Si deposition (PECVD#2|Amorphous Si Films and Their Stress}} |
||
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiN |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |{{rl|Sputtering Recipes|SiN deposition (Sputter 3)}} |
||
− | | <br> |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
+ | |<br> |
||
− | | {{rl|Sputtering Recipes|SiN deposition (Sputter 3)}} |
||
+ | |[[Sputtering_Recipes#Si3N4_deposition_.28IBD.29|R]] |
||
− | | [[Sputtering Recipes|A]] |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[Sputtering_Recipes#Si3N4_deposition_.28IBD.29|R]] |
||
+ | |{{rl|PECVD Recipes|SiN deposition (PECVD #1)}} |
||
− | | <br> |
||
+ | |{{rl|PECVD Recipes|SiN deposition (PECVD #2)}} |
||
− | | <br> |
||
− | | |
+ | |{{rl|PECVD Recipes|SiN deposition (Unaxis VLR)}} |
+ | |<br> |
||
− | | {{rl|PECVD Recipes|SiN deposition (PECVD #2)}} |
||
+ | |<br> |
||
− | | {{rl|PECVD Recipes|SiN deposition (Unaxis VLR)}} |
||
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E2}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|SiO2 deposition (Sputter 3)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering_Recipes#SiO2_deposition_.28IBD.29|R]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|PECVD Recipes|SiO2 deposition (PECVD #1)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|PECVD Recipes|SiO2 deposition (PECVD #2)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|PECVD Recipes|SiO2 deposition (Unaxis VLR)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|SiO2 deposition (ALD CHAMBER 3)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | {{rl|Atomic Layer Deposition Recipes|SiO2 deposition (ALD)}} |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiO<sub>x</sub>N<sub>y</sub> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[https://www.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#SiOxNy_deposition_.28IBD.29 A] |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
+ | |[[PECVD_Recipes#PECVD_1_.28PlasmaTherm_790.29|R]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[PECVD_Recipes#PECVD_1_.28PlasmaTherm_790.29|R]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Sn |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Thermal Evaporation Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SrF<sub>2</sub> |
− | | |
+ | |<br> |
− | | |
+ | |{{Al/E2}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ta |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ta deposition (Sputter 3)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |{{Al/E2}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Sputtering_Recipes#Ta2O5_deposition_.28IBD.29|R]] |
||
− | | <br> |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[Sputtering_Recipes#Ta2O5_deposition_.28IBD.29|R]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ti |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E3}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E4}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 3 (AJA ATC 2000-F)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |<br>[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | bgcolor="#eeffff" | {{rl|Sputtering Recipes|Ti-Au Deposition (Sputter 4)}} |
||
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |TiN |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[https://www.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29 R] |
||
− | | [[Sputtering Recipes|A]] |
||
− | | |
+ | |<br> |
+ | |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | [[Sputtering Recipes|R]] |
||
− | | |
+ | |<br> |
+ | |<br> |
||
− | | [[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |{{rl|Atomic Layer Deposition Recipes|TiN deposition (ALD CHAMBER 3)}} |
||
− | | <br> |
||
− | | |
+ | |<br> |
− | | {{rl|Atomic Layer Deposition Recipes|TiN deposition (ALD)}} |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |TiW |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|W-TiW Deposition (Sputter 4)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E2}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|Sputter 4 (AJA ATC 2200-V)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
+ | | bgcolor="#eeffff" |[[Sputtering_Recipes#TiO2_deposition_.28IBD.29|R]] |
||
− | | bgcolor="#eeffff" | {{rl|Sputtering Recipes|Sputter 4 (AJA ATC 2200-V)}} |
||
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|TiO2 deposition (ALD CHAMBER 3)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | {{rl|Atomic Layer Deposition Recipes|TiO2 deposition (ALD)}} |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |V |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
+ | |<br> |
||
− | | [[Sputtering Recipes|A]] |
||
+ | |<br> |
||
− | | [[Sputtering Recipes|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |W |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{Al/E1}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |[[Sputtering Recipes|A]] |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Sputtering Recipes|W deposition (Sputter 4)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | <br> |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Zn |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
+ | |[[Thermal Evaporation Recipes|A]] |
||
− | | <br> |
||
+ | |<br> |
||
− | | [[Thermal Evaporation Recipes|A]] |
||
+ | |<br> |
||
− | | [[Thermal Evaporation Recipes|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |ZnO |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|ZnO:Al deposition (ALD CHAMBER 1)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | {{rl|Atomic Layer Deposition Recipes|ZnO deposition (ALD)}} |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Zr |
− | | |
+ | |{{Al/E1}} |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |{{Al/E4}} |
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
+ | |[[Sputtering Recipes|A]] |
||
− | | <br> |
||
+ | |<br> |
||
− | | [[Sputtering Recipes|A]] |
||
+ | |<br> |
||
− | | [[Sputtering Recipes|A]] |
||
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | |
+ | |<br> |
− | | <br> |
||
− | | <br> |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |{{rl|Atomic Layer Deposition Recipes|ZrO2 deposition (ALD CHAMBER 3)}} |
− | | bgcolor="#eeffff" | |
+ | | bgcolor="#eeffff" |<br> |
− | | bgcolor="#eeffff" | {{rl|Atomic Layer Deposition Recipes|ZrO2 deposition (ALD)}} |
||
− | | bgcolor="#eeffff" | <br> |
||
|- |
|- |
||
− | ! width="20" |
+ | ! width="20" bgcolor="#d0e7ff" align="center" |'''Material''' |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_1_.28Sharon.29|E-Beam 1 (Sharon)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_2_.28Custom.29|E-Beam 2 (Custom)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_3_.28Temescal.29|E-Beam 3 (Temescal)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[E-Beam Evaporation Recipes#E-Beam_4_.28CHA.29|E-Beam 4 (CHA)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering Recipes#Sputter_3_.28ATC_2000-F.29|Sputter 3<br>(ATC 2000-F)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(ATC 2200-V)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[Sputtering Recipes|Sputter 5 (ATC 2200-V)]] |
− | | width=" |
+ | | width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]] |
− | | width=" |
+ | | width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]] |
− | | width=" |
+ | | width="65" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_2_.28Solder.29|Thermal Evap 2 (Solder)]] |
− | | width=" |
+ | | width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_1_.28PlasmaTherm_790.29|PECVD 1<br>(PlasmaTherm 790)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[PECVD Recipes#PECVD_2_.28Advanced_Vacuum.29|PECVD 2<br>(Advanced Vacuum)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29|Unaxis VLR ICP-PECVD]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAl)]] |
− | | width="65" bgcolor="#daf1ff" | |
+ | | width="65" bgcolor="#daf1ff" |[[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]] |
− | | width="65" bgcolor="#daf1ff" | [[Atomic_Layer_Deposition_Recipes|Atomic Layer Deposition (Oxford FlexAl)]] |
||
− | | width="65" bgcolor="#daf1ff" | [[Molecular Vapor Deposition|Molecular Vapor Deposition (Tool)]] |
||
|} |
|} |
||
Revision as of 21:28, 16 September 2019
- R = Recipe is available. Clicking this link will take you to the recipe.
- A = Material is available for use, but no recipes are provided.