=Lithography=
 
=Lithography=
  +
You can see our available photoresists on the [https://www.nanotech.ucsb.edu/wiki/index.php/Lithography_Recipes#Chemical_Datasheets Chemical Datasheets page].
 
 
{|
 
{|
 
|- valign="top"
 
|- valign="top"
 
| width="300" |
 
| width="300" |
  +
=====Photoresists and Lithography Chemicals=====
* [[Suss Aligners (SUSS MJB-3)]]
 
  +
* [[IR Aligner (SUSS MJB-3 IR)]]
 
  +
*See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page].
* [[DUV Flood Expose]]
 
  +
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]]
* [[Ovens 1, 2 & 3 (Labline)]]
 
  +
* [[Oven 4 (Fisher)]]
 
  +
=====Contact Aligners (Optical Exposure)=====
* [[Oven 5 (Labline)]]
 
  +
* [[High Temp Oven (Blue M)]]
 
  +
*[[Suss Aligners (SUSS MJB-3)|Contact Aligners (SUSS MJB-3)]]
* [[Vacuum Oven (YES)]]
 
* [[Holographic Lith/PL Setup (Custom)]]
+
*[[Contact Aligner (SUSS MA-6)]]
  +
*[[DUV Flood Expose]]
  +
  +
=====Direct-Write Lithography=====
  +
  +
*[[E-Beam Lithography System (JEOL JBX-6300FS)]]
  +
*[[SEM 1 (JEOL IT800SHL)|E-Beam Lithography (Nabity v9)]]
  +
*[[Focused Ion-Beam Lithography (Raith Velion)]]
  +
*[[Maskless Aligner (Heidelberg MLA150)]]
  +
  +
=====Other Patterning Systems=====
  +
  +
*[[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]]
 
| width="400" |
 
| width="400" |
  +
=====Steppers (Optical Exposure)=====
* [[Stepper 1 (GCA 6300)]]
 
  +
* [[Stepper 2 (AutoStep 200)]]
 
* [[Stepper 3 (ASML DUV)]]
+
*[[Stepper 1 (GCA 6300)|Stepper 1 (GCA 6300, i-line)]]
  +
*[[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]]
* [[E-Beam Lithography System (JEOL JBX-6300FS)]]
 
  +
*[[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]]
* [[Nano-Imprint (Nanonex NX2000)]]
 
  +
* [[Contact Aligner (SUSS MA-6)]]
 
  +
=====Thermal Processing for Photolithography=====
  +
  +
*[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all lab ovens]]
  +
*[[Ovens 1, 2 & 3 (Labline)]]
  +
*[[Oven 4 (Fisher)]]
  +
*[[Oven 5 (Labline)]]
  +
*[[High Temp Oven (Blue M)]]
  +
  +
=====Lithography Support=====
  +
  +
*The [https://wiki.nanotech.ucsb.edu/w/index.php?title=Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes.
  +
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 POLOS spinners] on Develop and Solvent benches
  +
*[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]]
 
|-
 
|-
 
|}
 
|}
   
= Vacuum Deposition =
+
=Vacuum Deposition=
   
 
{|
 
{|
 
|- valign="top"
 
|- valign="top"
| width="300" |
+
| width="300" |
  +
====Physical Vapor Deposition (PVD)====
*[[E-Beam 1 (Sharon)]]
 
  +
*[[E-Beam 2 (Custom)]]
 
  +
=====Thermal Evaporation=====
*[[E-Beam 3 (Temescal)]]
 
  +
*[[E-Beam 4 (CHA)]]
 
*[[Removed]]
+
*[[E-Beam 1 (Sharon)]]
*[[Sputter 3 (AJA ATC 2000-F)]]
+
*[[E-Beam 2 (Custom)]]
*[[Sputter 4 (AJA ATC 2200-V)]]
+
*[[E-Beam 3 (Temescal)]]
*[[Sputter 5 (Lesker AXXIS)]]
+
*[[E-Beam 4 (CHA)]]
  +
*[[E-Beam 5 (Plasys)]]
  +
*[[Thermal Evap 1]]
  +
*[[Thermal Evap 2 (Solder)]]
  +
  +
=====Sputter Deposition=====
  +
  +
*[[Sputter 3 (AJA ATC 2000-F)]]
  +
*[[Sputter 4 (AJA ATC 2200-V)]]
  +
*[[Sputter 5 (AJA ATC 2200-V)]]
  +
*[[Ion Beam Deposition (Veeco NEXUS)]]
  +
*[[SEM Sample Coater (Hummer)]]
  +
  +
| width="400" |
  +
=====Chemical Vapor Deposition (CVD)=====
   
  +
*[[PECVD 1 (PlasmaTherm 790)]]
| width="400" |
 
*[[PECVD 1 (PlasmaTherm 790)]]
+
*[[PECVD 2 (Advanced Vacuum)]]
*[[PECVD 2 (Advanced Vacuum)]]
+
*[[ICP-PECVD (Unaxis VLR)]]
*[[Thermal Evap 1]]
+
*[[Molecular Vapor Deposition]]
*[[Thermal Evap 2 (Solder)]]
 
*[[ICP-PECVD (Unaxis VLR)]]
 
*[[Ion Beam Deposition (Veeco NEXUS)]]
 
*[[Molecular Vapor Deposition]]
 
 
*[[Atomic Layer Deposision (Oxford FlexAL)|Atomic Layer Deposition (Oxford FlexAL)]]
 
*[[Atomic Layer Deposision (Oxford FlexAL)|Atomic Layer Deposition (Oxford FlexAL)]]
   
 
|}
 
|}
   
= Dry Etch =
+
=Dry Etch=
   
 
{|
 
{|
 
|- valign="top"
 
|- valign="top"
| width="300" |
+
| width="300" |
  +
=====Reactive Ion Etching (RIE)=====
*[[RIE 2 (MRC)]]
 
  +
*[[RIE 3 (MRC)]]
 
*[[RIE 5 (PlasmaTherm)]]
+
*[[RIE 2 (MRC)]]
*[[Si Deep RIE (PlasmaTherm/Bosch Etch)]]
+
*[[RIE 3 (MRC)]]
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)]]
+
*[[RIE 5 (PlasmaTherm)]]
  +
*[[Ashers (Technics PEII)]]
 
  +
=====Plasma Etching and Cleaning=====
*[[UV Ozone Reactor]]
 
  +
*[[CAIBE (Oxford Ion Mill)]]
 
  +
*[[Plasma Clean (YES EcoClean)]]
| width="400" |
 
*[[ICP Etch 1 (Panasonic E626I)]]
+
*[[Plasma Activation (EVG 810)]]
*[[ICP Etch 2 (Panasonic E640)]]
+
*[[Ashers (Technics PEII)]]
  +
  +
=====Etch Monitoring=====
  +
  +
*[[Laser Etch Monitoring]] (Endpoint Detection)
  +
*Optical Emission Spectra
  +
*Residual Gas Analyzer (RGA)
  +
| width="400" |
  +
=====ICP-RIE=====
  +
  +
*[[ICP Etch 1 (Panasonic E646V)]]
  +
*[[ICP Etch 2 (Panasonic E626I)]]
 
*[[ICP-Etch (Unaxis VLR)]]
 
*[[ICP-Etch (Unaxis VLR)]]
*[[Plasma Clean (Gasonics 2000)]]
+
*[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]]
  +
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]]
*[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch)]]
 
  +
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]]
*[[Plasma Activation (EVG 810)]]
 
  +
  +
=====Ion Milling and Reactive Ion Beam Etching=====
  +
  +
*[[CAIBE (Oxford Ion Mill)]]
  +
*[[Focused Ion-Beam Lithography (Raith Velion)]]
  +
  +
=====Other Dry Etching=====
  +
  +
*[[UV Ozone Reactor]]
  +
*[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch)]]
 
*[[Vapor HF Etch]]
 
*[[Vapor HF Etch]]
   
Line 79: Line 135:
 
|- valign="top"
 
|- valign="top"
 
| width="300" |
 
| width="300" |
* [[Wet Benches]]
+
*[[Wet Benches]]
 
**[[Solvent Cleaning Benches]]
 
**[[Solvent Cleaning Benches]]
 
**[[Spin Coat Benches]]
 
**[[Spin Coat Benches]]
 
**[[Develop Benches]]
 
**[[Develop Benches]]
 
**[[Toxic Corrosive Benches]]
 
**[[Toxic Corrosive Benches]]
  +
**[[Wet Benches#Wafer Toxic Corrosive Benches|Wafer Toxic Corrosive Bench]]
 
**[[HF/TMAH Processing Benches]]
 
**[[HF/TMAH Processing Benches]]
 
**[[Plating Bench]]
 
**[[Plating Bench]]
 
| width="400" |
 
| width="400" |
* [[Gold Plating Bench]]
+
*[[Gold Plating Bench]]
* [[Critical Point Dryer]]
+
*[[Critical Point Dryer]]
* [[Spin Rinse Dryer (SemiTool)]]
+
*[[Spin Rinse Dryer (SemiTool)]]
* [[Chemical-Mechanical Polisher (Logitech)]]
+
*[[Chemical-Mechanical Polisher (Logitech)]]
  +
*[[Mechanical Polisher (Allied)]]
  +
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]]
  +
*[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 Auto. Wet-Processing Spinners (POLOS)]
 
|-
 
|-
 
|}
 
|}
   
 
=Thermal Processing=
 
=Thermal Processing=
  +
{|
* [[Rapid Thermal Processor (AET RX6)]]
 
  +
|- valign="top"
* [[Strip Annealer]]
 
  +
| width="400" |
* [[Tube Furnace (Tystar 8300)]]
 
  +
*[[Rapid Thermal Processor (AET RX6)|Rapid Thermal Annealer/Processor "RTA" (AET RX6)]]
* [[Tube Furnace Wafer Bonding (Thermco)]]
 
  +
*[[Rapid Thermal Processor (SSI Solaris 150)]]
* [[Tube Furnace AlGaAs Oxidation (Linberg)]]
 
* [[Wafer Bonder (SUSS SB6-8E)]]
+
*[[Tube Furnace (Tystar 8300)]]
* [[Ovens 1, 2 & 3 (Labline)]]
+
*[[Tube Furnace Wafer Bonding (Thermco)]]
  +
*[[Tube Furnace AlGaAs Oxidation (Lindberg)]]
* [[Oven 4 (Fisher)]]
 
* [[Oven 5 (Labline)]]
+
*[[Wafer Bonder (SUSS SB6-8E)]]
  +
*[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]]
* [[High Temp Oven (Blue M)]]
 
  +
| width="400" |
* [[Vacuum Oven (YES)]]
 
  +
*[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all Lab Ovens]]
  +
**[[Ovens 1, 2 & 3 (Labline)]]
  +
**[[Oven 4 (Thermo-Fisher HeraTherm)]]
  +
**[[Oven 5 (Labline)]]
  +
**[[High Temp Oven (Blue M)]]
  +
|-
  +
|}
   
 
=Packaging=
 
=Packaging=
  +
''Back-end Fabrication Tools''
* [[Dicing Saw (ADT)]]
 
  +
{|
* [[Flip-Chip Bonder (Finetech)]]
 
  +
|
* [[Vacuum Sealer]]
 
  +
====Die Singulation / Down-sizing====
* [[Wire Saw (Takatori)]]
 
   
  +
*[[Dicing Saw (ADT)]]
=Inspection, Test and Characterization=
 
  +
*[[Wafer Cleaver (PELCO Flip-Scribe)|Manual Wafer Cleaver (PELCO Flipscribe)]]
  +
*[[Automated Wafer Cleaver (Loomis LSD-155LT)]]
  +
  +
====Other Packaging====
  +
  +
*[[Vacuum Sealer]]
  +
|
  +
====Wafer/Die Bonding====
  +
  +
*[[Flip-Chip Bonder (Finetech)]]
  +
  +
*[[Wafer Bonder (SUSS SB6-8E)]]
  +
*[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]]
  +
|}
  +
  +
=Measurement & Characterization=
  +
''[https://en.wikipedia.org/wiki/Metrology Metrology], Electrical/Optical Testing and Thin-Film/Materials [https://en.wikipedia.org/wiki/Characterization_(materials_science) Characterization] tools''
 
{|
 
{|
 
|- valign="top"
 
|- valign="top"
 
| width="300" |
 
| width="300" |
  +
=====Optical Microscopy=====
* [[Field Emission SEM 1 (FEI Sirion)]]
 
  +
* [[Field Emission SEM 2 (JEOL 7600F)]]
 
  +
*[[Microscopes|Optical Microscopes]] - ''General Use''
* [[Step Profile (Dektak IIA)]]
 
* [[Step Profilometer (Dektak 6M)]]
+
*[[Fluorescence Microscope (Olympus MX51)]]
  +
*[[Deep UV Optical Microscope (Olympus)]]
* [[Ellipsometer (Rudolph)]]
 
  +
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
* [[Microscopes]]
 
  +
*[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]]
* [[Probe Station & Curve Tracer]]
 
  +
*[[Suss Aligners (SUSS MJB-3)#Backside Alignment|Near-IR Inspection Scope (MJB-IR)]]
* [[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]]
 
  +
* Optical Film Thickness (Microscope-Mounted Filmetrics XYZ)
 
  +
=====Electron Microscopy=====
* [[Optical Film Thickness (Nanometric)]]
 
  +
* [[Goniometer]]
 
  +
*[[SEM 1 (JEOL IT800SHL)]]
  +
*[[Field Emission SEM 2 (JEOL IT800SHL)|SEM 2 (JEOL IT800SHL) w/ EDAX]]
  +
*[[SEM Sample Coater (Hummer)]]
  +
  +
=====Topographical Metrology=====
  +
  +
*[[Step Profilometer (KLA Tencor P-7)]]
  +
*[[Step Profilometer (DektakXT)]]
  +
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]]
  +
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
 
| width="400" |
 
| width="400" |
  +
* [[Film Stress (Tencor Flexus)]]
 
  +
=====Thin-Film/Material Analysis=====
* [[SEM Sample Coater (Hummer)]]
 
  +
* [[Surface Analysis (KLA/Tencor Surfscan)]]
 
  +
======Thickness + Optical Constants======
* [[Photo-emission & IR Microscope (QFI)]]
 
  +
* [[Ellipsometer (Woollam)]]
 
* [[Resistivity Mapper (CDE RESMAP)]]
+
*[[Ellipsometer (Woollam)]]
  +
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]]
* [[Laser Scanning Confocal M-scope (Olympus LEXT)]]
 
  +
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]]
* [[Deep UV Optical Microscope (Olympus)]]
 
  +
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]]
* [[Fluorescence Microscope (Olympus MX51)]]
 
  +
* [[Atomic Force Microsope (Dimension 3100/Nanoscope IVA)]]
 
  +
======Electrical Analysis======
  +
  +
*[[Resistivity Mapper (CDE RESMAP)]]
  +
*[[Probe Station & Curve Tracer|Probe Station & Source/Meter Units]]
  +
*[[IR Thermal Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]]
  +
  +
======Other Properties======
  +
  +
*[[Film Stress (Tencor Flexus)]]
  +
*[[Surface Analysis (KLA/Tencor Surfscan)|Particle Counts (KLA/Tencor Surfscan)]]
  +
*[[Photoluminescence PL Setup (Custom)]]
 
|-
 
|-
 
|}
 
|}

Latest revision as of 11:52, 1 March 2024

Lithography

Photoresists and Lithography Chemicals
Contact Aligners (Optical Exposure)
Direct-Write Lithography
Other Patterning Systems
Steppers (Optical Exposure)
Thermal Processing for Photolithography
Lithography Support

Vacuum Deposition

Physical Vapor Deposition (PVD)

Thermal Evaporation
Sputter Deposition
Chemical Vapor Deposition (CVD)

Dry Etch

Reactive Ion Etching (RIE)
Plasma Etching and Cleaning
Etch Monitoring
ICP-RIE
Ion Milling and Reactive Ion Beam Etching
Other Dry Etching

Wet Processing

See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.

Thermal Processing

Packaging

Back-end Fabrication Tools

Die Singulation / Down-sizing

Other Packaging

Wafer/Die Bonding

Measurement & Characterization

Metrology, Electrical/Optical Testing and Thin-Film/Materials Characterization tools

Optical Microscopy
Electron Microscopy
Topographical Metrology
Thin-Film/Material Analysis
Thickness + Optical Constants
Electrical Analysis
Other Properties