+ | Thermal evaporator #2 is the designated "Solder" evaporator. The tool is used primarily for solder materials including Gold, Indium and Tin. Use this tool for materials with low melting temperatures, or for materials that have a high risk of contamination in the e-beam evaporators. |
||
+ | = Detailed Specifications = |
||
− | = Materials Table = |
||
+ | Wafers up to 12" can be mounted. |
||
+ | =Documentation= |
||
− | {| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" class="collapsible collapsed wikitable" |
||
+ | *[[ media: Thermal Evaporator2.pdf|Operating Instructions]] |
||
− | |- |
||
+ | |||
− | ! colspan=6 width=1300 height=35 bgcolor="#D0E7FF" align="center"|<div style="font-size: 150%;">Materials Table</div> |
||
+ | = Materials Table = |
||
− | |- bgcolor="#D0E7FF" |
||
+ | For the materials tables, please visit the [[Thermal_Evaporation_Recipes#Materials_Table_(Thermal Evaporator #1)|Thermal Evaporation Recipe Page]]. |
||
− | ! width="45" bgcolor="#D0E7FF" align="center" | '''Material''' |
||
+ | ==Data== |
||
− | ! width="45" bgcolor="#D0E7FF" align="center" | '''Symbol''' |
||
+ | [[Thermal Evaporation Recipes]] |
||
− | ! width="45" bgcolor="#D0E7FF" align="center" | '''Density, g/cm3''' |
||
− | ! width="45" bgcolor="#D0E7FF" align="center" | '''Z Ratio''' |
||
− | ! width="45" bgcolor="#D0E7FF" align="center" | '''Tooling, %''' |
||
− | ! width="100" bgcolor="#D0E7FF" align="center" | '''Comments''' |
||
− | |- |
||
− | |Aluminum |
||
− | |Al |
||
− | |2.70 |
||
− | |1.08 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Antimony |
||
− | |Sb |
||
− | |2.70 |
||
− | |0.768 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Arsenic |
||
− | |As |
||
− | |5.73 |
||
− | |0.996 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Beryllium |
||
− | |Be |
||
− | |1.85 |
||
− | |0.543 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Boron |
||
− | |B |
||
− | |2.54 |
||
− | |0.389 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Cadmium |
||
− | |Cd |
||
− | |8.64 |
||
− | |0.682 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Cadmium sulfide |
||
− | |CdS |
||
− | |4.83 |
||
− | |1.02 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Cadmium telluride |
||
− | |CdTe |
||
− | |5.85 |
||
− | |0.980 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Calcium fluoride |
||
− | |CaF2 |
||
− | |3.18 |
||
− | |0.775 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Carbon (graphite) |
||
− | |C |
||
− | |2.25 |
||
− | |3.26 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Chromium |
||
− | |Cr |
||
− | |7.20 |
||
− | |0.305 |
||
− | |155 |
||
− | | |
||
− | |- |
||
− | |Cobalt |
||
− | |Co |
||
− | |8.71 |
||
− | |0.343 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Copper |
||
− | |Cu |
||
− | |8.93 |
||
− | |0.437 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Gallium |
||
− | |Ga |
||
− | |5.93 |
||
− | |0.593 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Gallium Arsenide |
||
− | |GaAs |
||
− | |5.31 |
||
− | |1.59 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Germanium |
||
− | |Ge |
||
− | |5.35 |
||
− | |0.516 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Gold |
||
− | |Au |
||
− | |19.30 |
||
− | |0.381 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Indium |
||
− | |In |
||
− | |7.30 |
||
− | |0.841 |
||
− | |120 |
||
− | | |
||
− | |- |
||
− | |Indium antimonide |
||
− | |InSb |
||
− | |5.76 |
||
− | |0.769 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Iridium |
||
− | |Ir |
||
− | |22.4 |
||
− | |0.129 |
||
− | | |
||
− | | |
||
− | |- |
||
− | |Iron |
||
− | |Fe |
||
− | |7.86 |
||
− | |0.349 |
||
− | | |
||
− | | |
||
− | |- |
Revision as of 10:47, 24 May 2017
|
About
Thermal evaporator #2 is the designated "Solder" evaporator. The tool is used primarily for solder materials including Gold, Indium and Tin. Use this tool for materials with low melting temperatures, or for materials that have a high risk of contamination in the e-beam evaporators.
Detailed Specifications
Wafers up to 12" can be mounted.
Documentation
Materials Table
For the materials tables, please visit the Thermal Evaporation Recipe Page.