(Updated status on CARY500, RIE5 and PECVD - deleted old announcements)
Line 12: Line 12:
   
 
===== RIE#5: Software Upgrades =====
 
===== RIE#5: Software Upgrades =====
  +
[[RIE_5_(PlasmaTherm)|RIE#5]] System has a leak - down until further notice.
[[RIE_5_(PlasmaTherm)|RIE#5]] Will be down next week from approximately Monday Sept. 17th to Thursday Sept. 20th, for a software upgrade to the same software running on the other PlasmaTherm tools.
 
All users will need to be retrained after the upgrade is complete.
+
All users will need to be retrained to use the new Cortex software.
// [[User:John d|John d]] 15:16, 11 September 2018 (PDT)
+
// [[User:Thibeault|Thibeault]] 16:40, 26 September 2018 (PDT)
   
 
===== PECVD#1: Software Upgrade =====
 
===== PECVD#1: Software Upgrade =====
Plasmatherm will be upgrading the system software on September 17th. The upgrade will take 3-5 days. After the upgrade is complete, everyone must be re-certified to use the tool. Please document any custom recipes that you may have, in case they can't be copied over.
+
Software upgrade in progress. After the upgrade is complete, everyone must be re-certified to use the tool. Please document any custom recipes that you may have, in case they can't be copied over.
// [[User:John d|John d]] 06:38, 15 August 2018 (PDT)
+
// [[User:Thibeault|Thibeault]] 16:40, 26 September 2018 (PDT)
  +
  +
===== CARY500 - Down - Decomissioned =====
  +
CARY 500 Spectrophotometer has failed - Will not be repaired - being decomissioned. New Filmetrics F10-RT-UVX being ordered as a replacement.
 
// [[User:Thibeault|Thibeault]] 16:40, 26 September 2018 (PDT)
   
 
===== RIE#5: SiCl4 Issue =====
 
===== RIE#5: SiCl4 Issue =====
Line 24: Line 28:
 
// [[User:John d|John d]] 17:22, 15 June 2018 (PDT)
 
// [[User:John d|John d]] 17:22, 15 June 2018 (PDT)
   
===== RIE#3: RF Issue =====
 
RF issues on RIE3 resolved. System is up. See email from tool owner for details.
 
// [[User:Thibeault|Thibeault]] 09:43, 20 September 2018 (PDT)
 
 
===== Sputter#4: TiW gun shorted =====
 
Gun will be looked at during next opening this Friday 9/21.
 
// [[User:Thibeault|Thibeault]] 08:31, 18 September 2018 (PDT)
 
   
 
<!---------- end of announcements ------------>
 
<!---------- end of announcements ------------>

Revision as of 16:40, 26 September 2018

UCSB NanoFab Announcements

Gasonics Up
RIE#5: Software Upgrades

RIE#5 System has a leak - down until further notice. All users will need to be retrained to use the new Cortex software. // Thibeault 16:40, 26 September 2018 (PDT)

PECVD#1: Software Upgrade

Software upgrade in progress. After the upgrade is complete, everyone must be re-certified to use the tool. Please document any custom recipes that you may have, in case they can't be copied over. // Thibeault 16:40, 26 September 2018 (PDT)

CARY500 - Down - Decomissioned

CARY 500 Spectrophotometer has failed - Will not be repaired - being decomissioned. New Filmetrics F10-RT-UVX being ordered as a replacement. // Thibeault 16:40, 26 September 2018 (PDT)

RIE#5: SiCl4 Issue

We have a flow rate problem on the SiCl4 gas line. You can only flow the SiCl4 for 5 minutes and then you have to wait 5 minutes before you flow it again. So in order to to do a 10 minute Etch you will have to do it in three steps flow 5 mi, wait 5mi, then flow 5min. // John d 17:22, 15 June 2018 (PDT)