Difference between revisions of "Lithography Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(added ARC row with links to DSK & DUV42P)
Line 25: Line 25:
 
|- bgcolor="#D0E7FF"
 
|- bgcolor="#D0E7FF"
 
! colspan="9" height="45" |<div style="font-size: 150%;">Photolithography Recipes</div>
 
! colspan="9" height="45" |<div style="font-size: 150%;">Photolithography Recipes</div>
  +
 
|- bgcolor="#D0E7FF"
 
|- bgcolor="#D0E7FF"
 
|<!-- INTENTIONALLY LEFT BLANK --><br>
 
|<!-- INTENTIONALLY LEFT BLANK --><br>
 
! colspan="2" bgcolor="#D0E7FF" align="center" |'''[[Contact Alignment Recipes|Contact Aligners]]'''
 
! colspan="2" bgcolor="#D0E7FF" align="center" |'''[[Contact Alignment Recipes|Contact Aligners]]'''
 
! colspan="3" bgcolor="#D0E7FF" align="center" |'''[[Stepper Recipes|Steppers]]'''
 
! colspan="3" bgcolor="#D0E7FF" align="center" |'''[[Stepper Recipes|Steppers]]'''
  +
   
 
|-
 
|-
 
! width="150" bgcolor="#D0E7FF" align="center" |'''Positive Resists'''
 
! width="150" bgcolor="#D0E7FF" align="center" |'''Positive Resists'''
 
{{LithRecipe Table}}
 
{{LithRecipe Table}}
  +
 
   
 
|-
 
|-
Line 42: Line 44:
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |AZ4210
 
| bgcolor="#D0E7FF" align="center" |AZ4210
Line 49: Line 52:
 
|A
 
|A
 
|<br>
 
|<br>
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |AZ4330RS
 
| bgcolor="#D0E7FF" align="center" |AZ4330RS
Line 56: Line 60:
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |OCG 825-35CS
 
| bgcolor="#D0E7FF" align="center" |OCG 825-35CS
Line 63: Line 68:
 
|A
 
|A
 
|<br>
 
|<br>
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |SPR 950-0.8
 
| bgcolor="#D0E7FF" align="center" |SPR 950-0.8
Line 70: Line 76:
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-0.9
 
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-0.9
Line 77: Line 84:
 
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
|<br>
 
|<br>
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-1.8
 
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-1.8
Line 84: Line 92:
 
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |SPR 220-3.0
 
| bgcolor="#D0E7FF" align="center" |SPR 220-3.0
Line 91: Line 100:
 
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
|<br>
 
|<br>
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |SPR 220-7.0
 
| bgcolor="#D0E7FF" align="center" |SPR 220-7.0
Line 98: Line 108:
 
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}}
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |THMR-IP3600 HP D
 
| bgcolor="#D0E7FF" align="center" |THMR-IP3600 HP D
Line 105: Line 116:
 
|A
 
|A
 
|<br>
 
|<br>
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |UV6-0.8
 
| bgcolor="#D0E7FF" align="center" |UV6-0.8
Line 112: Line 124:
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |[https://www.nanotech.ucsb.edu/wiki/index.php/Stepper_Recipes#Positive_Resist_.28ASML_DUV.29 R]
 
| bgcolor="EEFFFF" |[https://www.nanotech.ucsb.edu/wiki/index.php/Stepper_Recipes#Positive_Resist_.28ASML_DUV.29 R]
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |UV210-0.3
 
| bgcolor="#D0E7FF" align="center" |UV210-0.3
Line 119: Line 132:
 
|
 
|
 
|[https://www.nanotech.ucsb.edu/wiki/index.php/Stepper_Recipes#Positive_Resist_.28ASML_DUV.29 R]
 
|[https://www.nanotech.ucsb.edu/wiki/index.php/Stepper_Recipes#Positive_Resist_.28ASML_DUV.29 R]
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |UV26-2.5
 
| bgcolor="#D0E7FF" align="center" |UV26-2.5
Line 126: Line 140:
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |
 
| bgcolor="EEFFFF" |A
 
| bgcolor="EEFFFF" |A
  +
  +
 
|-
 
|-
 
! bgcolor="#D0E7FF" align="center" |'''Negative Resists'''
 
! bgcolor="#D0E7FF" align="center" |'''Negative Resists'''
 
{{LithRecipe Table}}
 
{{LithRecipe Table}}
 
   
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
Line 138: Line 153:
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|
 
|
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 2020
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 2020
Line 145: Line 161:
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|
 
|
  +
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 2035
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 2035
Line 152: Line 169:
 
|A
 
|A
 
|
 
|
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 2070
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 2070
Line 159: Line 177:
 
|A
 
|A
 
|
 
|
  +
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 5510
 
| bgcolor="#D0E7FF" align="center" |AZnLOF 5510
Line 166: Line 185:
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|
 
|
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |UVN30-0.8
 
| bgcolor="#D0E7FF" align="center" |UVN30-0.8
Line 173: Line 193:
 
|
 
|
 
|{{rl|Stepper Recipes|Negative Resist (ASML DUV)}}
 
|{{rl|Stepper Recipes|Negative Resist (ASML DUV)}}
  +
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" |SU-8 2005,2010, 2015
 
| bgcolor="#D0E7FF" align="center" |SU-8 2005,2010, 2015
Line 180: Line 201:
 
|A
 
|A
 
|
 
|
  +
 
|-
 
|-
 
| bgcolor="#D0E7FF" align="center" |SU-8 2075
 
| bgcolor="#D0E7FF" align="center" |SU-8 2075
Line 187: Line 209:
 
|A
 
|A
 
|
 
|
  +
 
|- bgcolor="EEFFFF"
 
|- bgcolor="EEFFFF"
 
| bgcolor="#D0E7FF" align="center" |NR9-1000,3000,6000PY
 
| bgcolor="#D0E7FF" align="center" |NR9-1000,3000,6000PY
Line 194: Line 217:
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}}
 
|
 
|
  +
  +
 
|-
 
|-
 
! bgcolor="#D0E7FF" align="center" | '''Anti-Reflection Coatings'''
  +
{{LithRecipe Table}}
 
  +
|- bgcolor="EEFFFF"
  +
| bgcolor="#D0E7FF" align="center" |DUV42-P
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|Stepper Recipes|DUV-42P}}
   
  +
|-
! bgcolor="#D0E7FF" align="center" |
 
  +
| bgcolor="#D0E7FF" align="center" |DS-K101-304
  +
|
  +
|
  +
|
  +
|
  +
|{{rl|Stepper Recipes|DS-K101-304}}
  +
  +
|-
  +
! bgcolor="#D0E7FF" align="center" | ''' '''
 
{{LithRecipe Table}}
 
{{LithRecipe Table}}
 
 
   
 
|}
 
|}
  +
<!-- end Litho Recipes table -->
   
 
==E-Beam Lithography Recipes==
 
==E-Beam Lithography Recipes==

Revision as of 12:15, 19 November 2019

General Information

This page contains information and links to recipes/datasheets spin-coated materials used in the facility. In general, the following information is provided for the following materials:

  • Underlayers: These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist. Datasheets are provided and some recipes are found in the Lift-Off Techniques section.
  • Holography: For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square. Recipes for silicon substrates are provided in the Holography section.
  • Anti-Reflection Coatings: Bottom Anti-Reflection Coatings (BARC) are used in the stepper systems, underneath the resists to eliminate substrate reflections that can affect resolution and repeatability for small, near resolution limited, feature sizes. Recipes using these materials are found within the photoresist recipes themselves. Datasheets are provided for reference on use of the materials.
  • Contrast Enhancement Materials (CEM): Used for resolution enhancement. Not for use in contact aligners. Recipes using these materials are found within the photoresist recipes themselves. Datasheets also provided.
  • Adhesion Promoters: These are used to improve wetting of photoresists to your substrate. Datasheets are provided on use of these materials.

Photolithography Recipes

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.


Photolithography Recipes

Contact Aligners Steppers


Positive Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


AZ4110 R R A A
AZ4210 R R A A
AZ4330RS R R A A
OCG 825-35CS A A A A
SPR 950-0.8 A A A A
SPR 955 CM-0.9 A R R R
SPR 955 CM-1.8 A A R R
SPR 220-3.0 R R R R
SPR 220-7.0 R R R R
THMR-IP3600 HP D

A A
UV6-0.8 R
UV210-0.3 R
UV26-2.5 A


Negative Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


AZ5214-EIR R R R R
AZnLOF 2020 R R R R
AZnLOF 2035 A A A A
AZnLOF 2070 A A A A
AZnLOF 5510 A A R R
UVN30-0.8 R
SU-8 2005,2010, 2015 A R A A
SU-8 2075 A A A A
NR9-1000,3000,6000PY R R A R


Anti-Reflection Coatings SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


DUV42-P R
DS-K101-304 R
SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


E-Beam Lithography Recipes

  • Under Development.

Automated Coat/Develop System Recipes (S-Cubed Flexi)

Recipes pre-loaded on the S-Cubed Flexi automated coat/bake/develop system. Only staff may write new recipes, contact the tool supervisor for more info.

To Be Added

Nanoimprinting Recipes

Holography Recipes

Low-K Spin-On Dielectric Recipes

Lift-Off Techniques

Chemicals Stocked + Datasheets

The following is a list of the lithography chemicals we have available in the lab, with links to the datasheets for each. The datasheets will often have important processing info such as spin-speed vs. thickness curves, typical process parameters, bake temps/times etc.

Positive Photoresists

i-line and broadband

DUV-248nm


Negative Photoresists

i-line and broadband

DUV-248nm


Underlayers


E-beam resists


Nanoimprinting
Contrast Enhancement Materials


Anti-Reflection Coatings


Adhesion Promoters


Spin-On Dielectrics

Low-K Spin-On Dielectrics such as Benzocyclobutane and Spin-on Glass


Developers


Photoresist Removers