Difference between revisions of "Fluorescence Microscope (Olympus MX51)"

From UCSB Nanofab Wiki
Jump to: navigation, search
(Documentation)
m (included fluor. in description, mentioned calibations locked)
 
(4 intermediate revisions by 3 users not shown)
Line 4: Line 4:
 
|super= Tony Bosch
 
|super= Tony Bosch
 
|location=Bay 6
 
|location=Bay 6
|description =
+
|description = Optical Microscope
 
|manufacturer = Olympus
 
|manufacturer = Olympus
  +
|model = MX51
 
|materials =
 
|materials =
 
|toolid=
 
|toolid=
 
}}
 
}}
 
=About=
 
=About=
  +
System for general purpose imaging. The system has bright field, dark-field, DIC imaging mode and Three fluorescence filters. Screen captures and calibrated measurements can be made through use of native Olympus' Streams Essential Software, installed on the attached computer.
   
 
=Detailed Specifications=
 
=Detailed Specifications=
  +
* Native ''Olympus Streams Essentials'' software & Camera:
  +
** Digital image capture & calibrated measurement (calibrations locked)
  +
* Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  +
* Reflected (Episcopic) & Transmitted (Diascopic) Illumination modes
  +
* Filters via rotatable selector:
  +
** '''BF''': Bright Field normal top-illuminated imaging
  +
** '''DF''': Dark-Field imaging
  +
** '''DIC''': Differential Interference Contrast "Nomarski" Imaging. Also requires "DIC-R" prism to be inserted. Polarization manually selected on DIC-R prism.
  +
* Fluorescence Filters (see [https://www.olympus-lifescience.com/en/microscope-resource/primer/techniques/fluorescence/anatomy/fluoromicroanatomy/ Olympus tutorial]):
  +
** '''''You must contact Tony Bosch for training on Fluorescence before using this feature!!!'''''
  +
** '''WB''': "Blue" Fluorescence Filter. Excitation: 450-480nm / Dichroic 500nm / Barrier 515nm+
  +
** '''WG''': "Green" Fluorescence Filter. Excitation: 510-550nm / Dichroic 570nm / Barrier 590nm+
  +
** '''WU''': "Ultraviolet" Fluorescence Filter. Excitation: 330-385nm / Dichroic 400nm / Barrier 420nm+
   
 
=Documentation=
 
=Documentation=
[[media:Olympus-Stream-Software.pdf|Stream Imaging Software Manual]]
+
*[[media:Olympus-Stream-Software.pdf|Stream Imaging Software Manual]]

Latest revision as of 22:07, 14 May 2019

Fluorescence Microscope (Olympus MX51)
Fluorescence.jpg
Tool Type Inspection, Test and Characterization
Location Bay 6
Supervisor Tony Bosch
Supervisor Phone (805) 893-3486
Supervisor E-Mail bosch@ece.ucsb.edu
Description Optical Microscope
Manufacturer Olympus
Model MX51


About

System for general purpose imaging. The system has bright field, dark-field, DIC imaging mode and Three fluorescence filters. Screen captures and calibrated measurements can be made through use of native Olympus' Streams Essential Software, installed on the attached computer.

Detailed Specifications

  • Native Olympus Streams Essentials software & Camera:
    • Digital image capture & calibrated measurement (calibrations locked)
  • Objectives: 5x, 10x, 20x, 50x, 100x, 150x
  • Reflected (Episcopic) & Transmitted (Diascopic) Illumination modes
  • Filters via rotatable selector:
    • BF: Bright Field normal top-illuminated imaging
    • DF: Dark-Field imaging
    • DIC: Differential Interference Contrast "Nomarski" Imaging. Also requires "DIC-R" prism to be inserted. Polarization manually selected on DIC-R prism.
  • Fluorescence Filters (see Olympus tutorial):
    • You must contact Tony Bosch for training on Fluorescence before using this feature!!!
    • WB: "Blue" Fluorescence Filter. Excitation: 450-480nm / Dichroic 500nm / Barrier 515nm+
    • WG: "Green" Fluorescence Filter. Excitation: 510-550nm / Dichroic 570nm / Barrier 590nm+
    • WU: "Ultraviolet" Fluorescence Filter. Excitation: 330-385nm / Dichroic 400nm / Barrier 420nm+

Documentation