Difference between revisions of "Automated Coat/Develop System (S-Cubed Flexi)"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(Added ToolTemplate - tool type and recepe)
(added ToolID (link to SUM))
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
{{tool|{{PAGENAME}}
 
{{tool|{{PAGENAME}}
 
|picture=TBD.jpg
 
|picture=TBD.jpg
|type = Lithography
 
 
|super= Tony Bosch
 
|super= Tony Bosch
 
|location=Bay 7
 
|location=Bay 7
 
|description = Automatic Coat/Bake/Develop
 
|description = Automatic Coat/Bake/Develop
|manufacturer = S-Cubed
+
|manufacturer = [https://www.s-cubed.com S-Cubed]
  +
|model = Flexi (Custom)
|ToolType = Wet Processing
+
|type = Wet Processing
 
|recipe = Lithography
 
|recipe = Lithography
|materials =
+
|materials =
|toolid=
+
|toolid=67
}}
+
}}
  +
'''THIS TOOL IS ONLY FOR STAFF USE AT THIS TIME.'''
  +
 
=About=
 
=About=
   
Line 17: Line 19:
 
=Detailed Specifications=
 
=Detailed Specifications=
   
* Wafer Size:
+
*Wafer Size: 100mm (150mm possible but not set up)
  +
*PR Coating Properties:
* Photoresists/Underlayers Available:
 
  +
**Uniformity < 1.0%
* Solvents Available:
 
  +
**< 100 particles on 100mm wafer
* Developers Available:
 
 
*Photoresists/Underlayers Available:
  +
**UV6-0.8
  +
**DS-K101-304
  +
**PMMA
  +
**PMGI SF11
  +
**PMGI SF5
 
*Solvents Available:
  +
**EBR100
 
*Developers Available:
  +
**AZ 300 MiF
   
 
=Process Information=
 
=Process Information=
   
  +
*Recipe Page for S-Cubed Coater: [[Lithography Recipes#Automated%20Coat.2FDevelop%20System%20Recipes%20.28S-Cubed%20Flexi.29|Lithography Recipes > Automated Coat/Develop System Recipes (S-Cubed Flexi]])
* TBD
 
  +
*See the [https://www.nanotech.ucsb.edu/wiki/index.php/Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Photolith. Chemicals page] for info on the installed resists.
   
 
=Operating Procedures=
 
=Operating Procedures=
   
  +
*''To Be Added''
* TBD
 

Revision as of 13:29, 13 November 2019

Automated Coat/Develop System (S-Cubed Flexi)
TBD.jpg
Tool Type Wet Processing
Location Bay 7
Supervisor Tony Bosch
Supervisor Phone (805) 893-3486
Supervisor E-Mail bosch@ece.ucsb.edu
Description Automatic Coat/Bake/Develop
Manufacturer S-Cubed
Model Flexi (Custom)
Wet Processing Recipes
Sign up for this tool


THIS TOOL IS ONLY FOR STAFF USE AT THIS TIME.

About

To Be Added

Detailed Specifications

  • Wafer Size: 100mm (150mm possible but not set up)
  • PR Coating Properties:
    • Uniformity < 1.0%
    • < 100 particles on 100mm wafer
  • Photoresists/Underlayers Available:
    • UV6-0.8
    • DS-K101-304
    • PMMA
    • PMGI SF11
    • PMGI SF5
  • Solvents Available:
    • EBR100
  • Developers Available:
    • AZ 300 MiF

Process Information

Operating Procedures

  • To Be Added