Difference between revisions of "Wafer Bonder (SUSS SB6-8E)"
Jump to navigation
Jump to search
Freeborn d (talk | contribs) |
|||
(6 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
− | {{ |
+ | {{tool2|{{PAGENAME}} |
|picture=WaferBonder.jpg |
|picture=WaferBonder.jpg |
||
|type = Thermal Processing |
|type = Thermal Processing |
||
− | |super= |
+ | |super= Aidan Hopkins |
+ | |super2= Lee Sawyer |
||
|phone=(805)839-3918x216 |
|phone=(805)839-3918x216 |
||
|location=Bay 7 |
|location=Bay 7 |
||
Line 11: | Line 12: | ||
|toolid=41 |
|toolid=41 |
||
}} |
}} |
||
− | = |
+ | =About= |
This is Karl-Suss model SB-6 substrate bonder. Wafer bonding of pieces to 6” wafers can be done at pressures from 5e-5 to 3e3 mBar and from 50°C to 550°C. This tool mates with the Karl-Suss MA-6 aligner to allow for aligned bonding. Forces up to 20 kN for a 150 mm wafer size are available. The system supports thermal compression as well as anodic bonding (up to 2000 V). The system is computer controlled with a windows environment allowing for multiple recipe steps and saving of recipes and data. The system is configured for manual loading of wafers. |
This is Karl-Suss model SB-6 substrate bonder. Wafer bonding of pieces to 6” wafers can be done at pressures from 5e-5 to 3e3 mBar and from 50°C to 550°C. This tool mates with the Karl-Suss MA-6 aligner to allow for aligned bonding. Forces up to 20 kN for a 150 mm wafer size are available. The system supports thermal compression as well as anodic bonding (up to 2000 V). The system is computer controlled with a windows environment allowing for multiple recipe steps and saving of recipes and data. The system is configured for manual loading of wafers. |
||
=Detailed Specifications= |
=Detailed Specifications= |
||
+ | |||
*Wafer bonding from 50°C to 550°C, +/- 5 degrees accuracy, +/- 3% uniformity |
*Wafer bonding from 50°C to 550°C, +/- 5 degrees accuracy, +/- 3% uniformity |
||
*Upper and lower heating of samples |
*Upper and lower heating of samples |
||
*5e-5 to 3e3 Torr environment bonding pressure, with Nitrogen |
*5e-5 to 3e3 Torr environment bonding pressure, with Nitrogen |
||
− | *Sample size: pieces to 6” wafers, aligned bonding by using MA/BA-6 aligner |
+ | *Sample size: pieces to 6” wafers, aligned bonding by using the [[Contact Aligner (SUSS MA-6)|MA/BA-6 aligner]] - contact supervisor for setup. |
*Anodic bonding to 2000 V |
*Anodic bonding to 2000 V |
||
*Windows-based computer control |
*Windows-based computer control |
||
*Wafer bonder currently set up for 4" wafers |
*Wafer bonder currently set up for 4" wafers |
||
+ | |||
+ | =Documentation= |
||
+ | |||
+ | *[https://wiki.nanofab.ucsb.edu/w/images/1/12/Bonder_Pressure_Rules_Vis_Aid.docx Bonder Pressure Rules Visual Aid] |
||
+ | *[https://wiki.nanofab.ucsb.edu/w/images/5/5c/Suss_Bonder_Recipe_Guidelines.docx Bonder Recipe Guidelines] |
Latest revision as of 10:53, 20 September 2023
|
About
This is Karl-Suss model SB-6 substrate bonder. Wafer bonding of pieces to 6” wafers can be done at pressures from 5e-5 to 3e3 mBar and from 50°C to 550°C. This tool mates with the Karl-Suss MA-6 aligner to allow for aligned bonding. Forces up to 20 kN for a 150 mm wafer size are available. The system supports thermal compression as well as anodic bonding (up to 2000 V). The system is computer controlled with a windows environment allowing for multiple recipe steps and saving of recipes and data. The system is configured for manual loading of wafers.
Detailed Specifications
- Wafer bonding from 50°C to 550°C, +/- 5 degrees accuracy, +/- 3% uniformity
- Upper and lower heating of samples
- 5e-5 to 3e3 Torr environment bonding pressure, with Nitrogen
- Sample size: pieces to 6” wafers, aligned bonding by using the MA/BA-6 aligner - contact supervisor for setup.
- Anodic bonding to 2000 V
- Windows-based computer control
- Wafer bonder currently set up for 4" wafers