Difference between revisions of "Vacuum Deposition Recipes"
(Delete Sputter1 and 2) (Tag: Visual edit) |
(Text replacement - "www.nanotech.ucsb.edu/wiki/" to "wiki.nanotech.ucsb.edu/wiki/") |
||
Line 19: | Line 19: | ||
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29|Sputter 3<br>(AJA ATC 2000-F)]] |
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29|Sputter 3<br>(AJA ATC 2000-F)]] |
||
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(AJA ATC 2200-V)]] |
| width="65" bgcolor="#daf1ff" |[[Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29|Sputter 4<br>(AJA ATC 2200-V)]] |
||
− | | width="65" bgcolor="#daf1ff" |[https:// |
+ | | width="65" bgcolor="#daf1ff" |[https://wiki.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#Sputter_5_.28AJA_ATC_2200-V.29 Sputter 5 (AJA ATC 2200-V)] |
| width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]] |
| width="55" bgcolor="#daf1ff" |[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|Ion Beam<br>Deposition (Veeco Nexus)]] |
||
| width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]] |
| width="45" bgcolor="#daf1ff" |[[Thermal Evaporation Recipes#Thermal_Evap_1|Thermal<br>Evap 1]] |
||
Line 71: | Line 71: | ||
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Al2O3 Deposition (Sputter 4)}} |
| bgcolor="#eeffff" |{{rl|Sputtering Recipes|Al2O3 Deposition (Sputter 4)}} |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
− | | bgcolor="#eeffff" |[https:// |
+ | | bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#Al2O3_deposition_.28IBD.29 R] |
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 187: | Line 187: | ||
|<br> |
|<br> |
||
|{{Al/E4}} |
|{{Al/E4}} |
||
− | |[https:// |
+ | |[https://wiki.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#Sputter_3_.28AJA_ATC_2000-F.29 R] |
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 568: | Line 568: | ||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
− | | bgcolor="#eeffff" |[https:// |
+ | | bgcolor="#eeffff" |[https://wiki.nanotech.ucsb.edu/wiki/index.php/PECVD_Recipes#Amorphous-Si_deposition_.28PECVD_.232.29 R] |
| bgcolor="#eeffff" |[[PECVD_Recipes#Amorphous_Si_.28100.25SiH4_Ar_He.29|R]] |
| bgcolor="#eeffff" |[[PECVD_Recipes#Amorphous_Si_.28100.25SiH4_Ar_He.29|R]] |
||
| bgcolor="#eeffff" |<br> |
| bgcolor="#eeffff" |<br> |
||
Line 615: | Line 615: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
− | |[https:// |
+ | |[https://wiki.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#SiOxNy_deposition_.28IBD.29 A] |
|<br> |
|<br> |
||
|<br> |
|<br> |
||
Line 715: | Line 715: | ||
|<br> |
|<br> |
||
|<br> |
|<br> |
||
− | |[https:// |
+ | |[https://wiki.nanotech.ucsb.edu/wiki/index.php/Sputtering_Recipes#Sputter_4_.28AJA_ATC_2200-V.29 R] |
|<br> |
|<br> |
||
|[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
|[[Sputtering_Recipes#Ion_Beam_Deposition_.28Veeco_NEXUS.29|A]] |
Revision as of 17:30, 6 April 2020
- R = Recipe is available. Clicking this link will take you to the recipe.
- A = Material is available for use, but no recipes are provided.