Difference between revisions of "Tool List"
Jump to navigation
Jump to search
(26 intermediate revisions by 6 users not shown) | |||
Line 7: | Line 7: | ||
=====Photoresists and Lithography Chemicals===== |
=====Photoresists and Lithography Chemicals===== |
||
− | *See the [https://wiki.nanotech.ucsb.edu/ |
+ | *See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page]. |
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
||
Line 13: | Line 13: | ||
*[[Suss Aligners (SUSS MJB-3)]] |
*[[Suss Aligners (SUSS MJB-3)]] |
||
⚫ | |||
*[[Contact Aligner (SUSS MA-6)]] |
*[[Contact Aligner (SUSS MA-6)]] |
||
*[[DUV Flood Expose]] |
*[[DUV Flood Expose]] |
||
Line 24: | Line 23: | ||
*[[Maskless Aligner (Heidelberg MLA150)]] |
*[[Maskless Aligner (Heidelberg MLA150)]] |
||
− | ===== |
+ | =====Other Patterning Systems===== |
+ | |||
− | *[[Nano-Imprint (Nanonex NX2000)]] |
||
*[[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]] |
*[[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]] |
||
| width="400" | |
| width="400" | |
||
Line 41: | Line 40: | ||
*[[Oven 5 (Labline)]] |
*[[Oven 5 (Labline)]] |
||
*[[High Temp Oven (Blue M)]] |
*[[High Temp Oven (Blue M)]] |
||
− | *[[Vacuum Oven (YES)]] |
||
=====Lithography Support===== |
=====Lithography Support===== |
||
− | *The [https://wiki.nanotech.ucsb.edu/ |
+ | *The [https://wiki.nanotech.ucsb.edu/w/index.php?title=Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes. |
− | *[https://signupmonkey.ece.ucsb.edu/ |
+ | *[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 POLOS spinners] on Develop and Solvent benches |
*[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]] |
*[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]] |
||
|- |
|- |
||
Line 56: | Line 54: | ||
|- valign="top" |
|- valign="top" |
||
| width="300" | |
| width="300" | |
||
− | + | ====Physical Vapor Deposition (PVD)==== |
|
+ | |||
+ | =====Thermal Evaporation===== |
||
*[[E-Beam 1 (Sharon)]] |
*[[E-Beam 1 (Sharon)]] |
||
Line 71: | Line 71: | ||
*[[Sputter 5 (AJA ATC 2200-V)]] |
*[[Sputter 5 (AJA ATC 2200-V)]] |
||
*[[Ion Beam Deposition (Veeco NEXUS)]] |
*[[Ion Beam Deposition (Veeco NEXUS)]] |
||
+ | *[[SEM Sample Coater (Hummer)]] |
||
| width="400" | |
| width="400" | |
||
Line 96: | Line 97: | ||
=====Plasma Etching and Cleaning===== |
=====Plasma Etching and Cleaning===== |
||
− | *[[Plasma Clean (Gasonics 2000)]] |
||
*[[Plasma Clean (YES EcoClean)]] |
*[[Plasma Clean (YES EcoClean)]] |
||
*[[Plasma Activation (EVG 810)]] |
*[[Plasma Activation (EVG 810)]] |
||
Line 112: | Line 112: | ||
*[[ICP Etch 2 (Panasonic E640)]] |
*[[ICP Etch 2 (Panasonic E640)]] |
||
*[[ICP-Etch (Unaxis VLR)]] |
*[[ICP-Etch (Unaxis VLR)]] |
||
+ | *[[Oxford ICP Etcher (PlasmaPro 100 Cobra)]] |
||
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]] |
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]] |
||
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]] |
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]] |
||
Line 118: | Line 119: | ||
*[[CAIBE (Oxford Ion Mill)]] |
*[[CAIBE (Oxford Ion Mill)]] |
||
+ | *[[Focused Ion-Beam Lithography (Raith Velion)]] |
||
=====Other Dry Etching===== |
=====Other Dry Etching===== |
||
Line 144: | Line 146: | ||
*[[Spin Rinse Dryer (SemiTool)]] |
*[[Spin Rinse Dryer (SemiTool)]] |
||
*[[Chemical-Mechanical Polisher (Logitech)]] |
*[[Chemical-Mechanical Polisher (Logitech)]] |
||
+ | *[[Mechanical Polisher (Allied)]] |
||
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
*[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
||
− | *[https://signupmonkey.ece.ucsb.edu/ |
+ | *[https://signupmonkey.ece.ucsb.edu/w/index.php?title=Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 Auto. Wet-Processing Spinners (POLOS)] |
|- |
|- |
||
|} |
|} |
||
Line 165: | Line 168: | ||
**[[Oven 4 (Thermo-Fisher HeraTherm)]] |
**[[Oven 4 (Thermo-Fisher HeraTherm)]] |
||
**[[Oven 5 (Labline)]] |
**[[Oven 5 (Labline)]] |
||
− | **[[Vacuum Oven (YES)]] |
||
**[[High Temp Oven (Blue M)]] |
**[[High Temp Oven (Blue M)]] |
||
⚫ | |||
|- |
|- |
||
|} |
|} |
||
=Packaging= |
=Packaging= |
||
+ | {| |
||
⚫ | |||
+ | ====Die Singulation / Down-sizing==== |
||
*[[Dicing Saw (ADT)]] |
*[[Dicing Saw (ADT)]] |
||
+ | *[[Wafer Cleaver (PELCO Flip-Scribe)|Wafer Cleaver (PELCO Flipscribe)]] |
||
⚫ | |||
+ | |||
+ | ====Other Packaging==== |
||
+ | |||
*[[Vacuum Sealer]] |
*[[Vacuum Sealer]] |
||
⚫ | |||
− | *[[Wire Saw (Takatori)]] |
||
+ | ====Wafer/Die Bonding==== |
||
+ | |||
⚫ | |||
+ | |||
⚫ | |||
+ | *[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]] |
||
⚫ | |||
=Inspection, Test and Characterization= |
=Inspection, Test and Characterization= |
||
Line 184: | Line 198: | ||
=====Optical Microscopy===== |
=====Optical Microscopy===== |
||
− | *[[Microscopes|Optical Microscopes]] |
+ | *[[Microscopes|Optical Microscopes]] - ''General Use'' |
*[[Fluorescence Microscope (Olympus MX51)]] |
*[[Fluorescence Microscope (Olympus MX51)]] |
||
*[[Deep UV Optical Microscope (Olympus)]] |
*[[Deep UV Optical Microscope (Olympus)]] |
||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
− | *[[ |
+ | *[[Digital Microscope (Olympus DSX1000)|Digital Microscope #7 (Olympus DSX1000)]] |
+ | |||
⚫ | |||
⚫ | |||
*[[Field Emission SEM 1 (FEI Sirion)]] |
*[[Field Emission SEM 1 (FEI Sirion)]] |
||
*[[Field Emission SEM 2 (JEOL 7600F)]] |
*[[Field Emission SEM 2 (JEOL 7600F)]] |
||
Line 200: | Line 215: | ||
*[[Step Profilometer (Dektak 6M)]] |
*[[Step Profilometer (Dektak 6M)]] |
||
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]] |
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]] |
||
⚫ | |||
− | **''Sub-micron Particle Counter'' |
||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
| width="400" | |
| width="400" | |
||
=====Thin-Film/Material Analysis===== |
=====Thin-Film/Material Analysis===== |
||
− | ====== |
+ | ======Thickness + Optical Constants====== |
+ | |||
*[[Ellipsometer (Woollam)]] |
*[[Ellipsometer (Woollam)]] |
||
− | *[[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]] |
||
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]] |
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]] |
||
− | *[[Optical Film Thickness (Nanometric)]] |
||
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] |
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] |
||
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
||
− | ====== |
+ | ======Electrical Analysis====== |
⚫ | |||
⚫ | |||
− | ====== Electrical Analysis ====== |
||
*[[Resistivity Mapper (CDE RESMAP)]] |
*[[Resistivity Mapper (CDE RESMAP)]] |
||
− | *[[Probe Station & Curve Tracer]] |
+ | *[[Probe Station & Curve Tracer|Probe Station & Source/Meter Units]] |
+ | *[[Photo-emission & IR Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]] |
||
− | =====Other |
+ | ======Other Properties====== |
⚫ | |||
⚫ | |||
⚫ | |||
*[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]] |
*[[Goniometer (Rame-Hart A-100)|Goniometer (Ramé-Hart A-100)]] |
||
**''Surface hydrophobicity'' |
**''Surface hydrophobicity'' |
||
⚫ | |||
⚫ | |||
⚫ | |||
|- |
|- |
||
|} |
|} |
||
− | |||
− | {{Special:Whatlinkshere}} |
Revision as of 14:17, 2 September 2022
Lithography
Photoresists and Lithography ChemicalsContact Aligners (Optical Exposure)Direct-Write Lithography
Other Patterning Systems |
Steppers (Optical Exposure)Thermal Processing for Photolithography
Lithography Support
|
Vacuum Deposition
Physical Vapor Deposition (PVD)Thermal Evaporation
Sputter Deposition |
Chemical Vapor Deposition (CVD) |
Dry Etch
Reactive Ion Etching (RIE)Plasma Etching and CleaningEtch Monitoring
|
ICP-RIE
Ion Milling and Reactive Ion Beam EtchingOther Dry Etching |
Wet Processing
See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.
Thermal Processing
Packaging
Die Singulation / Down-sizingOther Packaging |
Wafer/Die Bonding |
Inspection, Test and Characterization
Optical Microscopy
Electron MicroscopyTopographical Metrology |
Thin-Film/Material AnalysisThickness + Optical Constants
Electrical Analysis
Other Properties |