Difference between revisions of "Tool List"
Jump to navigation
Jump to search
(→Dry Etch: correct YES EcoClean link) |
m (→Inspection, Test and Characterization: renaming of sections) |
||
(11 intermediate revisions by 4 users not shown) | |||
Line 7: | Line 7: | ||
=====Photoresists and Lithography Chemicals===== |
=====Photoresists and Lithography Chemicals===== |
||
− | *See the [https:// |
+ | *See the [https://wiki.nanotech.ucsb.edu/wiki/index.php/Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page]. |
+ | *[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
||
=====Contact Aligners (Optical Exposure)===== |
=====Contact Aligners (Optical Exposure)===== |
||
Line 36: | Line 37: | ||
*[[High Temp Oven (Blue M)]] |
*[[High Temp Oven (Blue M)]] |
||
*[[Vacuum Oven (YES)]] |
*[[Vacuum Oven (YES)]] |
||
+ | |||
⚫ | |||
+ | =====Lithography Support===== |
||
+ | |||
⚫ | |||
+ | *[https://signupmonkey.ece.ucsb.edu/wiki/index.php/Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 POLOS spinners] on Develop and Solvent benches |
||
+ | *[[Spin Rinse Dryer (SemiTool)|Spin/Rinse/Dryer]] |
||
|- |
|- |
||
|} |
|} |
||
Line 82: | Line 88: | ||
*[[RIE 3 (MRC)]] |
*[[RIE 3 (MRC)]] |
||
*[[RIE 5 (PlasmaTherm)]] |
*[[RIE 5 (PlasmaTherm)]] |
||
+ | |||
− | *[[Ashers (Technics PEII)]] |
||
+ | =====Plasma Etching and Cleaning===== |
||
+ | |||
*[[Plasma Clean (Gasonics 2000)]] |
*[[Plasma Clean (Gasonics 2000)]] |
||
*[[Plasma Clean (YES EcoClean)]] |
*[[Plasma Clean (YES EcoClean)]] |
||
*[[Plasma Activation (EVG 810)]] |
*[[Plasma Activation (EVG 810)]] |
||
− | *[[ |
+ | *[[Ashers (Technics PEII)]] |
=====Etch Monitoring===== |
=====Etch Monitoring===== |
||
Line 101: | Line 109: | ||
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]] |
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]] |
||
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]] |
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]] |
||
+ | |||
+ | =====Ion Milling and Reactive Ion Beam Etching===== |
||
+ | |||
+ | *[[CAIBE (Oxford Ion Mill)]] |
||
=====Other Dry Etching===== |
=====Other Dry Etching===== |
||
Line 127: | Line 139: | ||
*[[Spin Rinse Dryer (SemiTool)]] |
*[[Spin Rinse Dryer (SemiTool)]] |
||
*[[Chemical-Mechanical Polisher (Logitech)]] |
*[[Chemical-Mechanical Polisher (Logitech)]] |
||
+ | *[[Automated Coat/Develop System (S-Cubed Flexi)|Auto. Coat/Develop (S-Cubed Flexi)]] |
||
+ | *[https://signupmonkey.ece.ucsb.edu/wiki/index.php/Wet_Benches#Automated_Wet-processing_Spinners_.28POLOS.29 Auto. Wet-Processing Spinners (POLOS)] |
||
|- |
|- |
||
|} |
|} |
||
Line 148: | Line 162: | ||
**[[Vacuum Oven (YES)]] |
**[[Vacuum Oven (YES)]] |
||
**[[High Temp Oven (Blue M)]] |
**[[High Temp Oven (Blue M)]] |
||
+ | | |
||
|- |
|- |
||
|} |
|} |
||
Line 162: | Line 177: | ||
|- valign="top" |
|- valign="top" |
||
| width="300" | |
| width="300" | |
||
− | =====Optical |
+ | =====Optical Microscopy===== |
*[[Microscopes|Optical Microscopes]] |
*[[Microscopes|Optical Microscopes]] |
||
Line 169: | Line 184: | ||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
*[[Photo-emission & IR Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]] |
*[[Photo-emission & IR Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]] |
||
+ | |||
+ | ===== Electron Microscopy ===== |
||
*[[Field Emission SEM 1 (FEI Sirion)]] |
*[[Field Emission SEM 1 (FEI Sirion)]] |
||
*[[Field Emission SEM 2 (JEOL 7600F)]] |
*[[Field Emission SEM 2 (JEOL 7600F)]] |
||
Line 181: | Line 198: | ||
**''Sub-micron Particle Counter'' |
**''Sub-micron Particle Counter'' |
||
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]] |
||
− | *[[Optical Profilometer - White-Light/Phase-Shift Interference (Filmetrics Profilm3D)]] |
||
| width="400" | |
| width="400" | |
||
− | =====Thin-Film Analysis |
+ | =====Thin-Film/Material Analysis===== |
+ | ====== Thickness + Optical Constants ====== |
||
*[[Ellipsometer (Woollam)]] |
*[[Ellipsometer (Woollam)]] |
||
⚫ | |||
⚫ | |||
*[[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]] |
*[[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]] |
||
⚫ | |||
⚫ | |||
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] |
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]] |
||
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]] |
||
+ | |||
⚫ | |||
+ | ====== Other Properties ====== |
||
⚫ | |||
⚫ | |||
+ | |||
+ | ====== Electrical Analysis ====== |
||
*[[Resistivity Mapper (CDE RESMAP)]] |
*[[Resistivity Mapper (CDE RESMAP)]] |
||
⚫ | |||
=====Other Tools===== |
=====Other Tools===== |
||
⚫ | |||
*[[Goniometer]] |
*[[Goniometer]] |
||
+ | **''Surface hydrophobicity'' |
||
⚫ | |||
|- |
|- |
||
|} |
|} |
Revision as of 10:48, 22 May 2020
Lithography
Photoresists and Lithography ChemicalsContact Aligners (Optical Exposure)Other Patterning Systems |
Steppers (Optical Exposure)Thermal Processing for Photolithography
Lithography Support
|
Vacuum Deposition
Physical Vapor Deposition (PVD)
Sputter Deposition |
Chemical Vapor Deposition (CVD) |
Dry Etch
Reactive Ion Etching (RIE)Plasma Etching and Cleaning
Etch Monitoring
|
ICP-RIE
Ion Milling and Reactive Ion Beam EtchingOther Dry Etching |
Wet Processing
See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.
Thermal Processing
Packaging
Inspection, Test and Characterization
Optical Microscopy
Electron MicroscopyTopographical Metrology |
Thin-Film/Material AnalysisThickness + Optical Constants
Other PropertiesElectrical AnalysisOther Tools
|