Difference between revisions of "Tool List"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(→‎Dry Etch: correct YES EcoClean link)
Line 5: Line 5:
 
|- valign="top"
 
|- valign="top"
 
| width="300" |
 
| width="300" |
===== Photoresists and Lithography Chemicals =====
+
=====Photoresists and Lithography Chemicals=====
* See the [https://www.nanotech.ucsb.edu/wiki/index.php/Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page].
 
  
===== Contact Aligners (Optical Exposure) =====
+
*See the [https://www.nanotech.ucsb.edu/wiki/index.php/Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Chemical Datasheets page].
* [[Suss Aligners (SUSS MJB-3)]]
 
* [[IR Aligner (SUSS MJB-3 IR)]]
 
* [[Contact Aligner (SUSS MA-6)]]
 
* [[DUV Flood Expose]]
 
  
===== Other Patterning Systems =====
+
=====Contact Aligners (Optical Exposure)=====
* [[E-Beam Lithography System (JEOL JBX-6300FS)]]
+
 
* [[Nano-Imprint (Nanonex NX2000)]]
+
*[[Suss Aligners (SUSS MJB-3)]]
* [[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]]
+
*[[IR Aligner (SUSS MJB-3 IR)]]
 +
*[[Contact Aligner (SUSS MA-6)]]
 +
*[[DUV Flood Expose]]
 +
 
 +
=====Other Patterning Systems=====
 +
 
 +
*[[E-Beam Lithography System (JEOL JBX-6300FS)]]
 +
*[[Nano-Imprint (Nanonex NX2000)]]
 +
*[[Holographic Lith/PL Setup (Custom)|Holographic Litho/PL Setup (Custom)]]
 
| width="400" |
 
| width="400" |
===== Steppers (Optical Exposure) =====
+
=====Steppers (Optical Exposure)=====
* [[Stepper 1 (GCA 6300)|Stepper 1 (GCA 6300, i-line)]]
 
* [[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]]
 
* [[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]]
 
  
===== Thermal Processing for Photolithography =====
+
*[[Stepper 1 (GCA 6300)|Stepper 1 (GCA 6300, i-line)]]
* [[Ovens - Overview of All Lab Ovens|Ovens - Overview of all lab ovens]]
+
*[[Stepper 2 (AutoStep 200)|Stepper 2 (AutoStep 200, i-line)]]
* [[Ovens 1, 2 & 3 (Labline)]]
+
*[[Stepper 3 (ASML DUV)|Stepper 3 (ASML DUV, Deep-UV)]]
* [[Oven 4 (Fisher)]]
+
 
* [[Oven 5 (Labline)]]
+
=====Thermal Processing for Photolithography=====
* [[High Temp Oven (Blue M)]]
+
 
* [[Vacuum Oven (YES)]]
+
*[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all lab ovens]]
* The [https://www.nanotech.ucsb.edu/wiki/index.php/Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes.
+
*[[Ovens 1, 2 & 3 (Labline)]]
 +
*[[Oven 4 (Fisher)]]
 +
*[[Oven 5 (Labline)]]
 +
*[[High Temp Oven (Blue M)]]
 +
*[[Vacuum Oven (YES)]]
 +
*The [https://www.nanotech.ucsb.edu/wiki/index.php/Wet_Benches#Spin_Coat_Benches Spinner Benches] have pre-set hotplates at various temperatures appropriate for common photoresist bakes.
 
|-
 
|-
 
|}
 
|}
  
= Vacuum Deposition =
+
=Vacuum Deposition=
  
 
{|
 
{|
 
|- valign="top"
 
|- valign="top"
 
| width="300" |
 
| width="300" |
===== Physical Vapor Deposition (PVD) =====
+
=====Physical Vapor Deposition (PVD)=====
*[[E-Beam 1 (Sharon)]]
 
*[[E-Beam 2 (Custom)]]
 
*[[E-Beam 3 (Temescal)]]
 
*[[E-Beam 4 (CHA)]]
 
*[[Thermal Evap 1]]
 
*[[Thermal Evap 2 (Solder)]]
 
  
===== Sputter Deposition =====
+
*[[E-Beam 1 (Sharon)]]
*[[Sputter 3 (AJA ATC 2000-F)]]  
+
*[[E-Beam 2 (Custom)]]
*[[Sputter 4 (AJA ATC 2200-V)]]  
+
*[[E-Beam 3 (Temescal)]]
 +
*[[E-Beam 4 (CHA)]]
 +
*[[Thermal Evap 1]]
 +
*[[Thermal Evap 2 (Solder)]]
 +
 
 +
=====Sputter Deposition=====
 +
 
 +
*[[Sputter 3 (AJA ATC 2000-F)]]
 +
*[[Sputter 4 (AJA ATC 2200-V)]]
 
*[[Sputter 5 (AJA ATC 2200-V)]]
 
*[[Sputter 5 (AJA ATC 2200-V)]]
 
*[[Ion Beam Deposition (Veeco NEXUS)]]
 
*[[Ion Beam Deposition (Veeco NEXUS)]]
  
 
| width="400" |
 
| width="400" |
===== Chemical Vapor Deposition (CVD) =====
+
=====Chemical Vapor Deposition (CVD)=====
*[[PECVD 1 (PlasmaTherm 790)]]  
+
 
*[[PECVD 2 (Advanced Vacuum)]]  
+
*[[PECVD 1 (PlasmaTherm 790)]]
*[[ICP-PECVD (Unaxis VLR)]]  
+
*[[PECVD 2 (Advanced Vacuum)]]
*[[Molecular Vapor Deposition]]  
+
*[[ICP-PECVD (Unaxis VLR)]]
 +
*[[Molecular Vapor Deposition]]
 
*[[Atomic Layer Deposision (Oxford FlexAL)|Atomic Layer Deposition (Oxford FlexAL)]]
 
*[[Atomic Layer Deposision (Oxford FlexAL)|Atomic Layer Deposition (Oxford FlexAL)]]
  
 
|}
 
|}
  
= Dry Etch =
+
=Dry Etch=
  
 
{|
 
{|
 
|- valign="top"
 
|- valign="top"
 
| width="300" |
 
| width="300" |
===== Reactive Ion Etching (RIE) =====
+
=====Reactive Ion Etching (RIE)=====
*[[RIE 2 (MRC)]]  
+
 
*[[RIE 3 (MRC)]]  
+
*[[RIE 2 (MRC)]]
*[[RIE 5 (PlasmaTherm)]]  
+
*[[RIE 3 (MRC)]]
*[[Ashers (Technics PEII)]]  
+
*[[RIE 5 (PlasmaTherm)]]
*[[Plasma Clean (Gasonics 2000)]]  
+
*[[Ashers (Technics PEII)]]
*[[Plamsa Clean (YES EcoClean)]]
+
*[[Plasma Clean (Gasonics 2000)]]
*[[Plasma Activation (EVG 810)]]  
+
*[[Plasma Clean (YES EcoClean)]]
 +
*[[Plasma Activation (EVG 810)]]
 
*[[CAIBE (Oxford Ion Mill)]]
 
*[[CAIBE (Oxford Ion Mill)]]
  
===== Etch Monitoring =====
+
=====Etch Monitoring=====
* [[Laser Etch Monitoring]] (Endpoint Detection)
+
 
* Optical Emission Spectra
+
*[[Laser Etch Monitoring]] (Endpoint Detection)
* Residual Gas Analyzer (RGA)
+
*Optical Emission Spectra
 +
*Residual Gas Analyzer (RGA)
 
| width="400" |
 
| width="400" |
===== ICP-RIE =====
+
=====ICP-RIE=====
*[[ICP Etch 1 (Panasonic E626I)]]  
+
 
*[[ICP Etch 2 (Panasonic E640)]]  
+
*[[ICP Etch 1 (Panasonic E626I)]]
 +
*[[ICP Etch 2 (Panasonic E640)]]
 
*[[ICP-Etch (Unaxis VLR)]]
 
*[[ICP-Etch (Unaxis VLR)]]
 
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]]
 
*[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Plasma-Therm SLR: Fluorine ICP (PlasmaTherm/SLR Fluorine Etcher)]]
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]]  
+
*[[DSEIII (PlasmaTherm/Deep Silicon Etcher)|Plasma-Therm DSE-iii (PlasmaTherm/Deep Silicon Etcher)]]
 +
 
 +
=====Other Dry Etching=====
  
===== Other Dry Etching =====
+
*[[UV Ozone Reactor]]
*[[UV Ozone Reactor]]  
+
*[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch)]]
*[[XeF2 Etch (Xetch)|XeF<sub>2</sub> Etch (Xetch)]]  
 
 
*[[Vapor HF Etch]]
 
*[[Vapor HF Etch]]
  
Line 103: Line 115:
 
|- valign="top"
 
|- valign="top"
 
| width="300" |
 
| width="300" |
* [[Wet Benches]]
+
*[[Wet Benches]]
 
**[[Solvent Cleaning Benches]]
 
**[[Solvent Cleaning Benches]]
 
**[[Spin Coat Benches]]
 
**[[Spin Coat Benches]]
Line 111: Line 123:
 
**[[Plating Bench]]
 
**[[Plating Bench]]
 
| width="400" |
 
| width="400" |
* [[Gold Plating Bench]]
+
*[[Gold Plating Bench]]
* [[Critical Point Dryer]]
+
*[[Critical Point Dryer]]
* [[Spin Rinse Dryer (SemiTool)]]
+
*[[Spin Rinse Dryer (SemiTool)]]
* [[Chemical-Mechanical Polisher (Logitech)]]
+
*[[Chemical-Mechanical Polisher (Logitech)]]
 
|-
 
|-
 
|}
 
|}
Line 122: Line 134:
 
|- valign="top"
 
|- valign="top"
 
| width="400" |
 
| width="400" |
* [[Rapid Thermal Processor (AET RX6)|Rapid Thermal Annealer/Processor "RTA" (AET RX6)]]
+
*[[Rapid Thermal Processor (AET RX6)|Rapid Thermal Annealer/Processor "RTA" (AET RX6)]]
* [[Rapid Thermal Processor (SSI Solaris 150)]]
+
*[[Rapid Thermal Processor (SSI Solaris 150)]]
* [[Tube Furnace (Tystar 8300)]]
+
*[[Tube Furnace (Tystar 8300)]]
* [[Tube Furnace Wafer Bonding (Thermco)]]
+
*[[Tube Furnace Wafer Bonding (Thermco)]]
* [[Tube Furnace AlGaAs Oxidation (Lindberg)]]
+
*[[Tube Furnace AlGaAs Oxidation (Lindberg)]]
* [[Wafer Bonder (SUSS SB6-8E)]]
+
*[[Wafer Bonder (SUSS SB6-8E)]]
* [[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]]
+
*[[Wafer Bonder (Logitech WBS7)|Wafer Bonder/Wax Mounting (Logitech WBS2)]]
 
| width="400" |
 
| width="400" |
* [[Ovens - Overview of All Lab Ovens|Ovens - Overview of all Lab Ovens]]
+
*[[Ovens - Overview of All Lab Ovens|Ovens - Overview of all Lab Ovens]]
** [[Ovens 1, 2 & 3 (Labline)]]
+
**[[Ovens 1, 2 & 3 (Labline)]]
** [[Oven 4 (Thermo-Fisher HeraTherm)]]
+
**[[Oven 4 (Thermo-Fisher HeraTherm)]]
** [[Oven 5 (Labline)]]
+
**[[Oven 5 (Labline)]]
** [[Vacuum Oven (YES)]]
+
**[[Vacuum Oven (YES)]]
** [[High Temp Oven (Blue M)]]
+
**[[High Temp Oven (Blue M)]]
 
|-
 
|-
 
|}
 
|}
  
 
=Packaging=
 
=Packaging=
* [[Dicing Saw (ADT)]]
+
 
* [[Flip-Chip Bonder (Finetech)]]
+
*[[Dicing Saw (ADT)]]
* [[Vacuum Sealer]]
+
*[[Flip-Chip Bonder (Finetech)]]
* [[Wire Saw (Takatori)]]
+
*[[Vacuum Sealer]]
 +
*[[Wire Saw (Takatori)]]
  
 
=Inspection, Test and Characterization=
 
=Inspection, Test and Characterization=
Line 149: Line 162:
 
|- valign="top"
 
|- valign="top"
 
| width="300" |
 
| width="300" |
===== Optical/Electron Microscopy =====
+
=====Optical/Electron Microscopy=====
* [[Microscopes|Optical Microscopes]]
+
 
* [[Fluorescence Microscope (Olympus MX51)]]
+
*[[Microscopes|Optical Microscopes]]
* [[Deep UV Optical Microscope (Olympus)]]
+
*[[Fluorescence Microscope (Olympus MX51)]]
* [[Laser Scanning Confocal M-scope (Olympus LEXT)]]
+
*[[Deep UV Optical Microscope (Olympus)]]
* [[Photo-emission & IR Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]]
+
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
* [[Field Emission SEM 1 (FEI Sirion)]]
+
*[[Photo-emission & IR Microscope (QFI)|Photo-emission & Thermal IR Microscope (QFI)]]
* [[Field Emission SEM 2 (JEOL 7600F)]]
+
*[[Field Emission SEM 1 (FEI Sirion)]]
* [[SEM Sample Coater (Hummer)]]
+
*[[Field Emission SEM 2 (JEOL 7600F)]]
 +
*[[SEM Sample Coater (Hummer)]]
 +
 
 +
=====Topographical Metrology=====
  
===== Topographical Metrology =====
+
*[[Step Profilometer (KLA Tencor P-7)]]
* [[Step Profilometer (KLA Tencor P-7)]]
+
*[[Step Profilometer (Dektak 6M)]]
* [[Step Profilometer (Dektak 6M)]]
+
*[[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]]
* [[Atomic Force Microscope (Bruker ICON)|Atomic Force Microsope (Bruker ICON)]]
+
*[[Surface Analysis (KLA/Tencor Surfscan)]]
* [[Surface Analysis (KLA/Tencor Surfscan)]]
+
**''Sub-micron Particle Counter''
** ''Sub-micron Particle Counter''
+
*[[Laser Scanning Confocal M-scope (Olympus LEXT)]]
* [[Laser Scanning Confocal M-scope (Olympus LEXT)]]
+
*[[Optical Profilometer - White-Light/Phase-Shift Interference (Filmetrics Profilm3D)]]
* [[Optical Profilometer - White-Light/Phase-Shift Interference (Filmetrics Profilm3D)]]
 
 
| width="400" |
 
| width="400" |
===== Thin-Film Analysis/Measurement =====
+
=====Thin-Film Analysis/Measurement=====
* [[Ellipsometer (Woollam)]]  
+
 
* [[Film Stress (Tencor Flexus)]]  
+
*[[Ellipsometer (Woollam)]]
* [[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]]
+
*[[Film Stress (Tencor Flexus)]]
* [[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]]
+
*[[Filmetrics F40-UV Microscope-Mounted|Optical Film Thickness (Microscope-Mounted Filmetrics F-40-UV)]]
* [[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]]
+
*[[Optical Film Thickness (Filmetrics)|Optical Film Thickness (Filmetrics F20)]]
* [[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]]
+
*[[Optical Film Thickness & Wafer-Mapping (Filmetrics F50)]]
* [[Optical Film Thickness (Nanometric)]]
+
*[[Optical Film Spectra + Optical Properties (Filmetrics F10-RT-UVX)|Reflection/Transmission Spectra & Optical Film Thickness (Filmetrics F10-RT-UVX)]]
* [[Resistivity Mapper (CDE RESMAP)]]
+
*[[Optical Film Thickness (Nanometric)]]
 +
*[[Resistivity Mapper (CDE RESMAP)]]
 +
 
 +
=====Other Tools=====
  
===== Other Tools =====
+
*[[Probe Station & Curve Tracer]]
* [[Probe Station & Curve Tracer]]
+
*[[Goniometer]]
* [[Goniometer]]
+
*[[Photoluminescence PL Setup (Custom)]]
* [[Photoluminescence PL Setup (Custom)]]
 
 
|-
 
|-
 
|}
 
|}

Revision as of 09:40, 25 September 2019

Lithography

Photoresists and Lithography Chemicals
Contact Aligners (Optical Exposure)
Other Patterning Systems
Steppers (Optical Exposure)
Thermal Processing for Photolithography

Vacuum Deposition

Physical Vapor Deposition (PVD)
Sputter Deposition
Chemical Vapor Deposition (CVD)

Dry Etch

Reactive Ion Etching (RIE)
Etch Monitoring
ICP-RIE
Other Dry Etching

Wet Processing

See the Chemical List page for stocked chemicals such as Developers, Etchants, Solvents etc.

Thermal Processing

Packaging

Inspection, Test and Characterization

Optical/Electron Microscopy
Topographical Metrology
Thin-Film Analysis/Measurement
Other Tools