*Standard 18" bell jar pumped by 8" Varian cryopump (HV8) driven by Ebara 2.1 compressor
 
*Low E-7 Torr ultimate pressure
 
*Rate Monitor: Maxtek TM-300
 
*Typical material rates: Al - 1 A/s @ 85 amps
 
**Au - 5 A/s @ 122 amps
 
**Cr - 2 A/s @ 85 amps
 
**Zn - 4.5 A/s @ 50 amps
 
  
 