Difference between revisions of "Thermal Evap 2 (Solder)"
Jump to navigation
Jump to search
Line 259: | Line 259: | ||
|Nb<sub>2</sub>O<sub>5</sub> | |Nb<sub>2</sub>O<sub>5</sub> | ||
|4.47 | |4.47 | ||
− | |z ratio has not been established | + | |1.00 |
− | + | |z ratio has not been established|- | |
− | |||
− | |- | ||
|Palladium | |Palladium | ||
|Pd | |Pd |
Revision as of 15:32, 29 August 2012
|
About
Materials Table
Materials Table
| ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Material | Symbol | Density, g/cm3 | Z Ratio | Tooling, % | Comments | |||||
Aluminum | Al | 2.70 | 1.08 | |||||||
Antimony | Sb | 6.620 | 0.768 | |||||||
Arsenic | As | 5.73 | 0.996 | |||||||
Beryllium | Be | 1.85 | 0.543 | |||||||
Boron | B | 2.54 | 0.389 | |||||||
Cadmium | Cd | 8.64 | 0.682 | |||||||
Cadmium sulfide | CdS | 4.83 | 1.02 | |||||||
Cadmium telluride | CdTe | 5.85 | 0.980 | |||||||
Calcium fluoride | CaF2 | 3.18 | 0.775 | Used often | ||||||
Carbon (graphite) | C | 2.25 | 3.26 | |||||||
Chromium | Cr | 7.20 | 0.305 | 155 | Used often | |||||
Cobalt | Co | 8.71 | 0.343 | |||||||
Copper | Cu | 8.93 | 0.437 | |||||||
Gallium | Ga | 5.93 | 0.593 | |||||||
Gallium Arsenide | GaAs | 5.31 | 1.59 | |||||||
Germanium | Ge | 5.35 | 0.516 | |||||||
Gold | Au | 19.30 | 0.381 | Used often | ||||||
Indium | In | 7.30 | 0.841 | 120 | USed often | |||||
Indium antimonide | InSb | 5.76 | 0.769 | |||||||
Iridium | Ir | 22.4 | 0.129 | |||||||
Iron | Fe | 7.86 | 0.349 | |||||||
Lead | Pb | 11.3 | 1.13 | |||||||
Lead sulfide | PbS | 7.50 | 0.566 | |||||||
Lithium fluoride | LiF | 2.638 | 0.778 | |||||||
Magnesium | Mg | 1.74 | 1.61 | |||||||
Magnesium oxide | MgO | 3.58 | 0.411 | |||||||
Magnesium Fluoride | MgF2 | 3.00 ( should be 3.18) | 0.427( should be 0.637) | |||||||
Manganese | Mn | 7.20 | 0.377 | |||||||
Manganese(II) Sulfide | MnS | 3.99 | 0.94 | |||||||
Mercury | Hg | 13.46 | 0.74 | |||||||
Molybdenum | Mo | 10.2 | 0.257 | |||||||
Nickel | Ni | 8.91 | 0.331 | Used often | ||||||
Niobium | Nb | 8.578 | 0.492 | |||||||
Niobium(V) Oxide | Nb2O5 | 4.47 | 1.00 | - | Palladium | Pd | 12.0 | 0.357 | ||
Platinum | Pt | 21.4 | 0.245 | |||||||
Potasium Cloride | KCl | 1.98 | 2.05 | |||||||
Selenium | Se | 4.82 | 0.864 | |||||||
Silicon | Si | 2.32 | 0.712 | |||||||
Silicon(II) Oxide | SiO | 2.13 | 0.87 | |||||||
Silicon dioxide (fused quarz) | SiO2 | 2.20 | 1.07 | |||||||
Silver | Ag | 10.5 | 0.529 | |||||||
Silver bromide | AgBr | 6.47 | 1.18 | |||||||
Silver chloride | AgCl | 5.56 | 1.32 | |||||||
Sodium | Na | 0.97 | 4.8 | |||||||
Sodium chloride | NaCl | 2.17 | 1.57 | |||||||
Tantalum | Ta | 16.6 | 0.262 | |||||||
Tantalum(IV) oxide | Ta2O5 | 8.2 | 0.30 | |||||||
Tin | Sn | 7.30 | 0.724 | Used often | ||||||
Titanium | Ti | 4.50 | 0.628 | Used often | ||||||
Titanium (IV) Oxide | TiO2 | 4.26 | 0.40 | |||||||
Titanium Oxide | TiO | 4.90 | N/A | |||||||
Tangsten | W | 19.3 | 0.163 | |||||||
Tangsten carbide | WC | 15.6 | 0.151 | |||||||
Zinc | Zn | 7.04 | 0.514 | Used often; Density should be 7.14 | ||||||
Zinc Oxide | ZnO | 5.61 | 0.556 | |||||||
Zinc Sulphide | ZnS | 4.09 | 0.775 | |||||||
Zirconium | Zr | 6.51 | 0.60 | Should be 6.40 | ||||||
Zirconium Oxide | ZrO2 | 5.6 | Should be 5.49 |