Difference between revisions of "Test Data of etching SiO2 with CHF3/CF4-ICP1"
Jump to navigation
Jump to search
(new section :pasted data from CHF3/CF4/O2 etch data) |
m (added entry to ICP1 historical data) |
||
Line 62: | Line 62: | ||
| |
| |
||
|[https://wiki.nanotech.ucsb.edu/w/images/4/49/I1210113.pdf] |
|[https://wiki.nanotech.ucsb.edu/w/images/4/49/I1210113.pdf] |
||
+ | |- |
||
+ | |3/2/2022 |
||
+ | |BP_ICP1_01 |
||
+ | |141.4 |
||
+ | | |
||
+ | | |
||
+ | |[https://wiki.nanotech.ucsb.edu/w/images/4/44/ICP1_01_45D_001.jpg <nowiki>[1]</nowiki>] [https://wiki.nanotech.ucsb.edu/w/images/8/87/ICP1_01_CS_003.jpg <nowiki>[2]</nowiki>] |
||
|} |
|} |
||
Revision as of 12:05, 8 March 2022
Date | Sample# | Etch Rate (nm/min) | Etch Selectivity (SiO2/PR) | Averaged Sidewall Angle (o) | SEM Images |
1/28/2019 | I11901 | 110 | 1.35 | see SEM → | [1] |
5/29/2019 | I11903 | 105 | 1.41 | [2] | |
1/13/2020 | I12001 | 78.0 | 1.06 | unusual - two regions | [3] |
Rate on 1/13/2020 is low by ~20%, so chamber was wet-cleaned on 1/21/2020. Data below for 1/23 shows rate returned to "normal". | |||||
1/23/2020 | I12002 | 109 | 1.16 | [4] | |
2/28/2020 | I12003 | 119 | 1.17 | 56.6 | [5] |
Sidewall profile on 2/28/2020 etches is slanted, chamber will be wet-cleaned on 3/2/2020 and re-tested. Data below shows etch returned to "normal". | |||||
3/3/2020 | I12004 | 110 | 1.05 | [6] | |
1/7/2021 | I12101 | 118 | 1.12 | [7] | |
3/2/2022 | BP_ICP1_01 | 141.4 | [1] [2] |
OLD Etch Test Data
Alternate SiO2 etch recipe with O2 included.
ICP#1: 0.5Pa, 50/500W, CHF3/CF4/O2=35/5/10sccm, time=210 sec | |||||
Date | Sample# | Etch Rate (nm/min) | Etch Selectivity (SiO2/PR) | Averaged Sidewall Angle (o) | SEM Images |
1/28/2019 | I11902 | 78.1 | 0.63 | [8] | |
5/29/2019 | I11904 | 71.1 | 0.58 | [9] |