Difference between revisions of "Test Data of etching SiO2 with CHF3/CF4-ICP1"
Jump to navigation
Jump to search
(Text replacement - "www.nanotech.ucsb.edu/wiki/" to "wiki.nanotech.ucsb.edu/wiki/") |
(comments on sidewall angle) |
||
Line 14: | Line 14: | ||
|110 |
|110 |
||
|1.35 |
|1.35 |
||
+ | |see SEM → |
||
− | | |
||
|[https://wiki.nanotech.ucsb.edu/wiki/images/b/b1/I11901.pdf] |
|[https://wiki.nanotech.ucsb.edu/wiki/images/b/b1/I11901.pdf] |
||
|- |
|- |
||
Line 28: | Line 28: | ||
|78.0 |
|78.0 |
||
|1.06 |
|1.06 |
||
+ | |unusual - two regions |
||
− | | |
||
|[https://wiki.nanotech.ucsb.edu/wiki/images/b/bb/I1200107.pdf] |
|[https://wiki.nanotech.ucsb.edu/wiki/images/b/bb/I1200107.pdf] |
||
|- |
|- |
||
− | | colspan="6" |Rate on 1/13/2020 is low by ~20%, so chamber was wet-cleaned on 1/21/2020. Data below for 1/23 shows rate returned to "normal". |
+ | | colspan="6" |''Rate on 1/13/2020 is low by ~20%, so chamber was wet-cleaned on 1/21/2020. Data below for 1/23 shows rate returned to "normal".'' |
|- |
|- |
||
|1/23/2020 |
|1/23/2020 |
||
Line 47: | Line 47: | ||
|[https://wiki.nanotech.ucsb.edu/wiki/images/e/ec/I1200301.pdf] |
|[https://wiki.nanotech.ucsb.edu/wiki/images/e/ec/I1200301.pdf] |
||
|- |
|- |
||
− | | colspan="6" |Sidewall profile on 2/28/2020 etches is slanted, chamber will be wet-cleaned on 3/2/2020 and re-tested. |
+ | | colspan="6" |''Sidewall profile on 2/28/2020 etches is slanted, chamber will be wet-cleaned on 3/2/2020 and re-tested. Data below shows etch returned to "normal".'' |
|- |
|- |
||
|3/3/2020 |
|3/3/2020 |
Revision as of 09:10, 23 April 2020
ICP#1: 0.5Pa, 50/900W, CHF3/CF4=10/30 sccm, time=210 sec | |||||
Date | Sample# | Etch Rate (nm/min) | Etch Selectivity (SiO2/PR) | Averaged Sidewall Angle (o) | SEM Images |
1/28/2019 | I11901 | 110 | 1.35 | see SEM → | [1] |
5/29/2019 | I11903 | 105 | 1.41 | [2] | |
1/13/2020 | I12001 | 78.0 | 1.06 | unusual - two regions | [3] |
Rate on 1/13/2020 is low by ~20%, so chamber was wet-cleaned on 1/21/2020. Data below for 1/23 shows rate returned to "normal". | |||||
1/23/2020 | I12002 | 109 | 1.16 | [4] | |
2/28/2020 | I12003 | 119 | 1.17 | 56.6 | [5] |
Sidewall profile on 2/28/2020 etches is slanted, chamber will be wet-cleaned on 3/2/2020 and re-tested. Data below shows etch returned to "normal". | |||||
3/3/2020 | I12004 | 110 | 1.05 | [6] |