Difference between revisions of "Test Data of etching SiO2 with CHF3/CF4"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(add a SEM pic)
(add a new data point)
Line 58: Line 58:
 
|
 
|
 
|[https://wiki.nanotech.ucsb.edu/w/images/0/0c/I2210102.pdf]
 
|[https://wiki.nanotech.ucsb.edu/w/images/0/0c/I2210102.pdf]
  +
|-
  +
|5/19/2021
  +
|I22102
  +
|101
  +
|1.11
  +
|
  +
|
 
|}
 
|}

Revision as of 19:05, 19 May 2021

ICP#2: 0.5Pa, 50/900W, CHF3/CF4=10/30 sccm, time=210 sec
Date Sample# Etch Rate (nm/min) Etch Selectivity (SiO2/PR) Averaged Sidewall Angle (o) SEM Images
10/5/2018 SiO2#02 160 1.2 82.1 [1]
1/28/2019 I21901 146 1.23 [2]
3/6/2019 I21904 151 1.23 85.6 [3]
7/18/2019 I21905 162 1.37 [4]
1/16/2020 I22001 149 1.21 [5]
8/9/2020 I22002 102 0.86 caused by air leaking to CHF3 channel [6]
1/7/2021 I22101 144 1.20 [7]
5/19/2021 I22102 101 1.11