Difference between revisions of "Test Data of Etching SiO2 with CHF3/CF4-Florine ICP Etcher"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(adding a SEM)
 
Line 1: Line 1:
 
{| class="wikitable"
 
{| class="wikitable"
| colspan="6" |Florine ICP: 3.8mT, 50/800W, CHF3/CF4=10/30sccm, time=90 sec
+
| colspan="6" |Florine ICP: 3.8mT, 50/800W, CHF3/CF4=10/30sccm, and Time=90 sec
 
|-
 
|-
 
|Date
 
|Date

Latest revision as of 18:30, 2 February 2021

Florine ICP: 3.8mT, 50/800W, CHF3/CF4=10/30sccm, and Time=90 sec
Date Sample# Etch Rate (nm/min) Etch Selectivity (SiO2/PR) Averaged Sidewall Angle (o) SEM Images
1/28/2021 FE2102 309 0.99 [1]