Difference between revisions of "Template:Publications"
Line 38: | Line 38: | ||
[https://doi.org/10.35848/1882-0786/ac1230 Appl. Phys. Express A, '''14''', 086502, 2021] |
[https://doi.org/10.35848/1882-0786/ac1230 Appl. Phys. Express A, '''14''', 086502, 2021] |
||
+ | |||
+ | == [https://doi.org/10.1063/5.0054005 Demonstration of high efficiency cascaded blue and green micro-light-emitting diodes with independent junction control] == |
||
+ | ''Panpan Li, Hongjian Li ... James Speck, Shuji Nakamura, Steve DenBaars'' |
||
+ | |||
+ | [https://doi.org/10.1063/5.0054005 Appl. Phys. Lett., '''118''', 261104, 2021] |
||
== [https://doi.org/10.1116/6.0001030 Highly Selective and Vertical Etch of Silicon Dioxide using Ruthenium Films as an Etch Mask] == |
== [https://doi.org/10.1116/6.0001030 Highly Selective and Vertical Etch of Silicon Dioxide using Ruthenium Films as an Etch Mask] == |
Revision as of 17:09, 3 November 2021
Publications using the Nanofab
0.5T0.5R—An Ultracompact RRAM Cell Uniquely Enabled by van der Waals Heterostructures
D. Zhang, C. -H. Yeh, W. Cao and K. Banerjee
IEEE Transactions on Electron Devices, 68 (4), 2033-2040 (2021)
Laser soliton microcombs heterogeneously integrated on silicon
Chao Xiang, Junqiu Liu, .... Bowers, J.
Science, 373 (650), 99-103 (2021)
Ultrabright Entangled-Photon-Pair Generation from an AlGaAs-On-Insulator Microring Resonator
Trevor J. Steiner, Joshua E. Castro, Lin Chang ... John E. Bowers, and Galan Moody
Visible light photonic integrated Brillouin laser
Chauhan, N., Isichenko, A., Liu, K. ... Blumenthal, D.
Nature Communications, 12, p.4685 (2021)
Optically synchronized fibre links using spectrally pure chip-scale lasers
Brodnik, G.M., Harrington, M.W., Dallyn, J.H. .... Blumenthal, D.
Nature Photonics, 15, 588–593 (2021)
Demonstration of high wall-plug efficiency III-nitride micro-light-emitting diodes with MOCVD-grown tunnel junction contacts using chemical treatments
Matthew S. Wong, Matthew S. Wong ... James Speck, Shuji Nakamura, Steve DenBaars
Appl. Phys. Express A, 14, 086502, 2021
Demonstration of high efficiency cascaded blue and green micro-light-emitting diodes with independent junction control
Panpan Li, Hongjian Li ... James Speck, Shuji Nakamura, Steve DenBaars
Appl. Phys. Lett., 118, 261104, 2021
Highly Selective and Vertical Etch of Silicon Dioxide using Ruthenium Films as an Etch Mask
William J. Mitchell, Brian J. Thibeault, Demis D. John, and Thomas E. Reynolds
Journal of Vacuum Science and Technology A, 39, 043204, May 27th 2021
A similar process flow can be found at the Fluorine-ICP Recipe Page.
Stimulated Raman Adiabatic Passage in Optomechanics
Vitaly Fedoseev, Fernando Luna, Ian Hedgepeth, Wolfgang Löffler, and Dirk Bouwmeester
Phys. Rev. Lett., 126, 113601, March 19th 2021
Deuterated silicon dioxide for heterogeneous integration of ultra-low-loss waveguides
Warren Jin, Demis D. John, Jared F. Bauters, Tony Bosch, Brian J. Thibeault, and John E. Bowers
Optics Letters Vol. 45, Issue 12, pp. 3340-3343 (2020)
Quantum supremacy using a programmable superconducting processor
F. Arute, K. Arya, ... Harmut Neven, John M. Martinis
Nature, volume 574, pages 505–510 (2019)
An optical-frequency synthesizer using integrated photonics
D. T. Spencer, T. Drake, ... John E. Bowers, Scott A. Diddams, Scott B. Papp
Nature, volume 557, pages 81–85 (2018)
Continuous-wave operation of m-plane GaN-based vertical-cavity surface-emitting lasers with a tunnel junction intracavity contact
C.A. Forman, S.G. Lee, ... S.P. DenBaars, S. Nakamura
Applied Physics Letters, Vol. 112, Issue 11, 2018
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-contrast Astronomy
S.R. Meeker, B.A. Mazin, ... G. Vasisht, E. Serabyn
Astronomical Society of the Pacific, Volume 130, Issue 988, pp. 065001 (2018)
Dielectrophoretic Nanoparticle Aggregation for On-Demand Surface Enhanced Raman Spectroscopy Analysis
R. Salemmilani, B.D. Piorek, A.W. Fountain, M. Moskovits, C.D. Meinhart
Analytical Chemistry, 90, 13, 7930-7936 (2018)
Demonstration of Constant 8 W/mm Power Density at 10, 30, and 94 GHz in State-of-the-Art Millimeter-Wave N-Polar GaN MISHEMTs
B. Romanczyk, S. Wienecke, M. Guidry, H. Li, E. Ahmadi, X. Zheng, S. Keller, U.K. Mishra
IEEE Transactions On Electron Devices, Vol. 65, No. 1 (2018)