Difference between revisions of "Template:News"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(updated dates with BT's signature)
 
(78 intermediate revisions by 2 users not shown)
Line 1: Line 1:
<startFeed />
+
<startfeed />
 +
<!---feedBurner name="UCSBNanofab-NewsFeed" /-->
 
<!-- Description of the RSS feed -->
 
<!-- Description of the RSS feed -->
News from the U.C. Santa Barbara Nanofabrication Facility
+
''News from the U.C. Santa Barbara Nanofabrication Facility.''
 +
<!-- these comments only show up when viewing the page source, but not when the page is viewed normally (eg. the RSS feed) -->
 +
<!--
 +
'''How to add news items'''
  
<!-- the following only shows up when vieweing the template page, but not when the page is included elsewhere (eg. the RSS feed) -->
+
* New news item should be inserted at the TOP of the list
<noinclude>  
+
* Item titles should have a level 3 heading, like so:  === MyArticleTitle ===
'''How to add new news items'''
+
* Each item should finish with the user signature (four tildes: ~~~~) on it's own separated line.  When you 'Save' the page, this will be replaced with a timestamp and your user name. 
 +
* Then delete your username, leaving only the two dashes, so "[[User:Thibeault|-- Brain Thibeault]]" becomes "[[User:Thibeault|-- ]]"
 +
* Also delete the "[[... (talk)]]" link
 +
* The timestamp determines the order of items in the feed. Items without a timestamp will show up at the end of the feed in random order.
 +
-->
 +
<!---------------------------------------------->
 +
<!-------- NEWS ITEMS: newest on top -------->
 +
 
 +
=== Oxford PlasmaPro ICP Etcher installed ===
 +
We have a new ICP etcher in Bay 2:
 +
[[Oxford_ICP_Etcher_(PlasmaPro_100_Cobra)]]
 +
 
 +
The tool has been qualified for InP Ridge and InGaAsP Grating etches, and is intended for III-V etching in general (GaAs, GaN, GaSb etc.)
 +
 
 +
In addition, the tool is capable of Atomic Layer Etching on various materials.  Contact [[Tony_Bosch | the supervisor]] for training.
 +
// [[User:John d|John d]] 11:27, 29 September 2021 (PDT)
 +
 
 +
=== SiO2 etching, High-Aspect Ratio ===
 +
[[Bill_Mitchell|Dr. Bill Mitchell]] recently published an article detailing [[Template:Publications#Highly_Selective_and_Vertical_Etch_of_Silicon_Dioxide_using_Ruthenium_Films_as_an_Etch_Mask|'''high-aspect ratio SiO2 etching (JVST-A, May 2021)''']] in the [[ICP_Etching_Recipes#PlasmaTherm.2FSLR_Fluorine_Etcher|Plasma-Therm Fluorine ICP etcher]], using a novel Ruthenium Hard Mask. 
 +
 
 +
Ruthenium can be deposited using the [[Atomic_Layer_Deposition_Recipes#Ru_deposition_.28ALD_CHAMBER_1.29|Oxford ALD]] or [[Sputtering_Recipes#Ru_Deposition_.28Sputter_4.29|AJA Sputter]] and etched in one of the [[ICP_Etching_Recipes#Ru_.28Ruthenium.29_Etch_.28Panasonic_2.29|Panasonic ICP's]].
 +
 
 +
You can find a full process flow at the [[ICP_Etching_Recipes#SiO2_Etching_.28Fluorine_ICP_Etcher.29|FL-ICP's Recipe Page]], in this case using a Sputtered Ru hard mask and I-line stepper lithography.
 +
// [[User:John d|John d]] 08:05, 27 May 2021 (PDT)
  
* New news item should be inserted at the TOP of the list
+
=== Wafer Polisher available ===
* Item titles should have a level 2 heading (`==`)
+
We have added an [https://wiki.nanotech.ucsb.edu/wiki/Mechanical_Polisher_(Allied) Allied Wafer Polish] tool to our equipment list. Contact [[Brian Lingg]] for more information.  // [[User:John d|John d]] 16:49, 10 May 2021 (PDT)
* Each item should finish with user signature (four tildes `[[User:John d|-- Demis]] ([[User talk:John d|talk]]) 22:37, 27 November 2017 (PST)`).  When you **Save** the page, this will be replaced with a timestamp and your user name.  The timestamp determines the order of items in the feed - items without a timestamp show up at the end.
 
</noinclude>
 
  
<!-- News items, newest on top -->
+
=== Digital Microscope: Olympus DSX-1000 ===
== New Deep Silicon Etcher ==
+
You'll see a new digital microscope in Bay 4/Metrology, that's our new [https://www.olympus-ims.com/en/microscope/dsx1000/high-resolution-model/ Olympus DSX-1000]. We are currently developing procedures, keep an eye out for training emails.
New Plasma-Therm Versaline DSE III DRIE etcher is qualified for bosch etch and single-step etches, and is available for use. The new tool features much higher silicon etch rates, improved uniformity, and allows for photoresist up to the edges of the wafer. [[User:John d|-- Demis]] ([[User talk:John d|talk]]) 22:16, 27 November 2017 (PST)
+
// [[User:John d|John d]] 13:49, 8 April 2021 (PDT)
  
== 2016 Survey Results ==  
+
=== Raith Velion: FIB/SEM Installation ===
See the May 2016 User Survey Results:  {{file|Survey052016.pdf|Survey Results}}  [[User:Thibeault|-- Brian Thibeault]] 12:00, 01 May 2016
+
We have installed a new state-of-the-art focused ion beam/electron beam tool in Bay 1.
 +
The Raith Velion enables synchronized interferometric stage, Focused-ion Beam Lithography with ~10nm features or less, live SEM during writing, and Electron-Beam Lithography.
  
== CAIBE Ion Mill Available ==
+
Learn more about the tool's capabilities at the Raith website:
The [[CAIBE (Oxford Ion Mill)]] is up and running! Contact [[Brian Lingg]] for more information. [[User:Thibeault|-- Brian Thibeault]] 12:00, 01 July 2015
+
* [https://www.raith.com/products/velion.html?mobile=0 Raith Products: Velion].
 +
* [https://www.youtube.com/watch?v=rW5w6nMhwfQ VIDEO: Synchronized FIB beam + Laser Interferometric Stage write, with live SEM]
  
== NanoFiles SFTP Online ==
+
Tool qualification is currently underway.
Files generated with Nanofab tools (SEM images, AFM profiles, etc.) are now available on the nanofab SFTP server. Please check [http://signupmonkey.ece.ucsb.edu SignupMonkey] for details. [[User:Thibeault|-- Brian Thibeault]] 12:00, 07 July 2013
+
[[Dan Read|Dr. Dan Read]] is be the resident expert on this new tool.
  
 +
// [[User:John d|John d]] 06:53, 30 November 2020 (PST)
  
 +
<!---------- end of announcements ------------>
 +
<!---------------------------------------------->
 
<!--DO NOT EDIT BELOW THIS LINE-->
 
<!--DO NOT EDIT BELOW THIS LINE-->
<endFeed />
+
<endfeed />
 
<noinclude>[[Category:Templates]]</noinclude>
 
<noinclude>[[Category:Templates]]</noinclude>

Latest revision as of 12:36, 7 January 2022

News from the U.C. Santa Barbara Nanofabrication Facility.

Oxford PlasmaPro ICP Etcher installed

We have a new ICP etcher in Bay 2: Oxford_ICP_Etcher_(PlasmaPro_100_Cobra)

The tool has been qualified for InP Ridge and InGaAsP Grating etches, and is intended for III-V etching in general (GaAs, GaN, GaSb etc.)

In addition, the tool is capable of Atomic Layer Etching on various materials. Contact the supervisor for training. // John d 11:27, 29 September 2021 (PDT)

SiO2 etching, High-Aspect Ratio

Dr. Bill Mitchell recently published an article detailing high-aspect ratio SiO2 etching (JVST-A, May 2021) in the Plasma-Therm Fluorine ICP etcher, using a novel Ruthenium Hard Mask.

Ruthenium can be deposited using the Oxford ALD or AJA Sputter and etched in one of the Panasonic ICP's.

You can find a full process flow at the FL-ICP's Recipe Page, in this case using a Sputtered Ru hard mask and I-line stepper lithography. // John d 08:05, 27 May 2021 (PDT)

Wafer Polisher available

We have added an Allied Wafer Polish tool to our equipment list. Contact Brian Lingg for more information. // John d 16:49, 10 May 2021 (PDT)

Digital Microscope: Olympus DSX-1000

You'll see a new digital microscope in Bay 4/Metrology, that's our new Olympus DSX-1000. We are currently developing procedures, keep an eye out for training emails. // John d 13:49, 8 April 2021 (PDT)

Raith Velion: FIB/SEM Installation

We have installed a new state-of-the-art focused ion beam/electron beam tool in Bay 1. The Raith Velion enables synchronized interferometric stage, Focused-ion Beam Lithography with ~10nm features or less, live SEM during writing, and Electron-Beam Lithography.

Learn more about the tool's capabilities at the Raith website:

Tool qualification is currently underway. Dr. Dan Read is be the resident expert on this new tool.

// John d 06:53, 30 November 2020 (PST)