Difference between revisions of "Template:News"
(amscope entry) |
|||
(97 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
+ | <startfeed /> |
||
− | * The ([[ASML DUV]]) is up and running for 4" wafers! Contact [[Adam Abrahamsen]] for more information. ''(5/22/2013)'' |
||
+ | <!---feedBurner name="UCSBNanofab-NewsFeed" /--> |
||
− | * Effective immediately we will no longer be returning confiscated glassware. ''(3/1/2012)'' |
||
+ | <!-- Description of the RSS feed --> |
||
− | * Garment changeout will occur next Friday (3/16), please remember to remove items from your pockets. ''(3/5/2012)'' |
||
+ | ''News from the U.C. Santa Barbara Nanofabrication Facility.'' |
||
− | * All supply water to the Nanofab will be shutoff on Sunday (3/11). Contact [[Tom Reynolds]] with any questions or concerns. ''(3/8/2012)'' |
||
+ | <!-- these comments only show up when viewing the page source, but not when the page is viewed normally (eg. the RSS feed) --> |
||
+ | <!-- |
||
+ | '''How to add news items''' |
||
+ | |||
+ | * New news item should be inserted at the TOP of the list |
||
+ | * Item titles should have a level 3 heading, like so: === MyArticleTitle === |
||
+ | * Each item should finish with the user signature (four tildes: ~~~~) on it's own separated line. When you 'Save' the page, this will be replaced with a timestamp and your user name. |
||
+ | * Then delete your username, leaving only the two dashes, so "[[User:Thibeault|-- Brain Thibeault]]" becomes "[[User:Thibeault|-- ]]" |
||
+ | * Also delete the "[[... (talk)]]" link |
||
+ | * The timestamp determines the order of items in the feed. Items without a timestamp will show up at the end of the feed in random order. |
||
+ | --> |
||
+ | <!----------------------------------------------> |
||
+ | <!-------- NEWS ITEMS: newest on top --------> |
||
+ | === Wide FOV Microscope Installed === |
||
+ | We have installed an AmScope stereo microscope in Bay 4 for wide field-of-view digital imaging/capture, with >2cm of FOV currently available. Wiki page here: [[Microscopes#Microscope_.238:_AmScope_Wide_Field_of_View_Stereoscope_.28Bay_4.29|AmScope Wide Field of View Stereoscope]] |
||
+ | // [[User:John d|John d]] 14:52, 19 April 2023 (PDT) |
||
+ | |||
+ | === Loomis Scribe & Break installed === |
||
+ | We have installed a new [https://loomisinc.com/lsd-155lt/ Loomis LSD-155LT] Automated Scribe & Break Cleaving tool in the Back-End Processing lab. Qualifications are underway. Contact [[Aidan_Hopkins|supervisor, Aidan Hopkins]], for more information. |
||
+ | // [[User:John d|John d]] 09:41, 16 April 2023 (PDT) |
||
+ | |||
+ | === JEOL SEM Installed === |
||
+ | SEM #1 has been replaced with a new JEOL SEM, which is currently being installed and qualified. Contact the [[Aidan_Hopkins|supervisor, Aidan Hopkins]], for more information. |
||
+ | // [[User:John d|John d]] 09:00, 11 April 2023 (PDT) |
||
+ | |||
+ | === Dektak XT installed === |
||
+ | We have replaced the old Dektak 6M with a new Dektak XT profilometer. This tool will provide robust, fast metrology for rapid in-process topography inspection. |
||
+ | // [[User:John d|John d]] 10:41, 25 January 2023 (PST) |
||
+ | |||
+ | === New Process Control data tables === |
||
+ | We have added [[Process_Group_-_Process_Control_Data|"Process Control Data"]] - data on deposition/etch repeatability - to a number of our highest used etchers and deposition tools. The datasheets are linked in multiple places, mainly on the Recipes pages for each tool, or on the general Recipes pages for [[Vacuum_Deposition_Recipes|'''Deposition Recipes''']] or [[Dry_Etching_Recipes|'''Etch Recipes''']]. |
||
+ | // [[User:John d|John d]] 16:07, 5 January 2023 (PST) |
||
+ | |||
+ | === Oxford PlasmaPro ICP Etcher installed === |
||
+ | We have a new ICP etcher in Bay 2: |
||
+ | [[Oxford_ICP_Etcher_(PlasmaPro_100_Cobra)]] |
||
+ | |||
+ | The tool has been qualified for InP Ridge and InGaAsP Grating etches, and is intended for III-V etching in general (GaAs, GaN, GaSb etc.) |
||
+ | |||
+ | In addition, the tool is capable of Atomic Layer Etching on various materials. Contact [[Tony_Bosch | the supervisor]] for training. |
||
+ | // [[User:John d|John d]] 11:27, 29 September 2021 (PDT) |
||
+ | |||
+ | === SiO2 etching, High-Aspect Ratio === |
||
+ | [[Bill_Mitchell|Dr. Bill Mitchell]] recently published an article detailing [[Template:Publications#Highly_Selective_and_Vertical_Etch_of_Silicon_Dioxide_using_Ruthenium_Films_as_an_Etch_Mask|'''high-aspect ratio SiO2 etching (JVST-A, May 2021)''']] in the [[ICP_Etching_Recipes#PlasmaTherm.2FSLR_Fluorine_Etcher|Plasma-Therm Fluorine ICP etcher]], using a novel Ruthenium Hard Mask. |
||
+ | |||
+ | Ruthenium can be deposited using the [[Atomic_Layer_Deposition_Recipes#Ru_deposition_.28ALD_CHAMBER_1.29|Oxford ALD]] or [[Sputtering_Recipes#Ru_Deposition_.28Sputter_4.29|AJA Sputter]] and etched in one of the [[ICP_Etching_Recipes#Ru_.28Ruthenium.29_Etch_.28Panasonic_2.29|Panasonic ICP's]]. |
||
+ | |||
+ | You can find a full process flow at the [[ICP_Etching_Recipes#SiO2_Etching_.28Fluorine_ICP_Etcher.29|FL-ICP's Recipe Page]], in this case using a Sputtered Ru hard mask and I-line stepper lithography. |
||
+ | // [[User:John d|John d]] 08:05, 27 May 2021 (PDT) |
||
+ | |||
+ | === Wafer Polisher available === |
||
+ | We have added an [https://wiki.nanotech.ucsb.edu/wiki/Mechanical_Polisher_(Allied) Allied Wafer Polish] tool to our equipment list. Contact [[Bill_Millerski]] for more information. // [[User:John d|John d]] 16:49, 10 May 2021 (PDT) |
||
+ | |||
+ | === Digital Microscope: Olympus DSX-1000 === |
||
+ | You'll see a new digital microscope in Bay 4/Metrology, that's our new [https://www.olympus-ims.com/en/microscope/dsx1000/high-resolution-model/ Olympus DSX-1000]. We are currently developing procedures, keep an eye out for training emails. |
||
+ | // [[User:John d|John d]] 13:49, 8 April 2021 (PDT) |
||
+ | |||
+ | === Raith Velion: FIB/SEM Installation === |
||
+ | We have installed a new state-of-the-art focused ion beam/electron beam tool in Bay 1. |
||
+ | The Raith Velion enables synchronized interferometric stage, Focused-ion Beam Lithography with ~10nm features or less, live SEM during writing, and Electron-Beam Lithography. |
||
+ | |||
+ | Learn more about the tool's capabilities at the Raith website: |
||
+ | * [https://www.raith.com/products/velion.html?mobile=0 Raith Products: Velion]. |
||
+ | * [https://www.youtube.com/watch?v=rW5w6nMhwfQ VIDEO: Synchronized FIB beam + Laser Interferometric Stage write, with live SEM] |
||
+ | |||
+ | Tool qualification is currently underway. |
||
+ | [[Dan Read|Dr. Dan Read]] is the resident expert on this new tool. |
||
+ | |||
+ | // [[User:John d|John d]] 06:53, 30 November 2020 (PST) |
||
+ | |||
+ | <!---------- end of announcements ------------> |
||
+ | <!----------------------------------------------> |
||
+ | <!--DO NOT EDIT BELOW THIS LINE--> |
||
+ | <endfeed /> |
||
<noinclude>[[Category:Templates]]</noinclude> |
<noinclude>[[Category:Templates]]</noinclude> |
Revision as of 14:52, 19 April 2023
News from the U.C. Santa Barbara Nanofabrication Facility.
Wide FOV Microscope Installed
We have installed an AmScope stereo microscope in Bay 4 for wide field-of-view digital imaging/capture, with >2cm of FOV currently available. Wiki page here: AmScope Wide Field of View Stereoscope // John d 14:52, 19 April 2023 (PDT)
Loomis Scribe & Break installed
We have installed a new Loomis LSD-155LT Automated Scribe & Break Cleaving tool in the Back-End Processing lab. Qualifications are underway. Contact supervisor, Aidan Hopkins, for more information. // John d 09:41, 16 April 2023 (PDT)
JEOL SEM Installed
SEM #1 has been replaced with a new JEOL SEM, which is currently being installed and qualified. Contact the supervisor, Aidan Hopkins, for more information. // John d 09:00, 11 April 2023 (PDT)
Dektak XT installed
We have replaced the old Dektak 6M with a new Dektak XT profilometer. This tool will provide robust, fast metrology for rapid in-process topography inspection. // John d 10:41, 25 January 2023 (PST)
New Process Control data tables
We have added "Process Control Data" - data on deposition/etch repeatability - to a number of our highest used etchers and deposition tools. The datasheets are linked in multiple places, mainly on the Recipes pages for each tool, or on the general Recipes pages for Deposition Recipes or Etch Recipes. // John d 16:07, 5 January 2023 (PST)
Oxford PlasmaPro ICP Etcher installed
We have a new ICP etcher in Bay 2: Oxford_ICP_Etcher_(PlasmaPro_100_Cobra)
The tool has been qualified for InP Ridge and InGaAsP Grating etches, and is intended for III-V etching in general (GaAs, GaN, GaSb etc.)
In addition, the tool is capable of Atomic Layer Etching on various materials. Contact the supervisor for training. // John d 11:27, 29 September 2021 (PDT)
SiO2 etching, High-Aspect Ratio
Dr. Bill Mitchell recently published an article detailing high-aspect ratio SiO2 etching (JVST-A, May 2021) in the Plasma-Therm Fluorine ICP etcher, using a novel Ruthenium Hard Mask.
Ruthenium can be deposited using the Oxford ALD or AJA Sputter and etched in one of the Panasonic ICP's.
You can find a full process flow at the FL-ICP's Recipe Page, in this case using a Sputtered Ru hard mask and I-line stepper lithography. // John d 08:05, 27 May 2021 (PDT)
Wafer Polisher available
We have added an Allied Wafer Polish tool to our equipment list. Contact Bill_Millerski for more information. // John d 16:49, 10 May 2021 (PDT)
Digital Microscope: Olympus DSX-1000
You'll see a new digital microscope in Bay 4/Metrology, that's our new Olympus DSX-1000. We are currently developing procedures, keep an eye out for training emails. // John d 13:49, 8 April 2021 (PDT)
Raith Velion: FIB/SEM Installation
We have installed a new state-of-the-art focused ion beam/electron beam tool in Bay 1. The Raith Velion enables synchronized interferometric stage, Focused-ion Beam Lithography with ~10nm features or less, live SEM during writing, and Electron-Beam Lithography.
Learn more about the tool's capabilities at the Raith website:
- Raith Products: Velion.
- VIDEO: Synchronized FIB beam + Laser Interferometric Stage write, with live SEM
Tool qualification is currently underway. Dr. Dan Read is the resident expert on this new tool.
// John d 06:53, 30 November 2020 (PST)