Difference between revisions of "Template:Announcements"
(MA-6 down) |
(deleted wifi maint.) |
||
(367 intermediate revisions by 6 users not shown) | |||
Line 2: | Line 2: | ||
<!--feedBurner name="UCSBNanofab-Announcements" /--> |
<!--feedBurner name="UCSBNanofab-Announcements" /--> |
||
<!-- Description of the RSS feed --> |
<!-- Description of the RSS feed --> |
||
+ | '''''Equipment Status''''' |
||
− | ''UCSB NanoFab Announcements'' |
||
+ | ---- |
||
<!-- |
<!-- |
||
− | SEE THE BOTTOM OF THIS PAGE FOR INSTRUCTIONS ON ADDING NEWS ITEMS. |
+ | SEE THE BOTTOM OF THIS PAGE FOR DETAILED INSTRUCTIONS ON ADDING NEWS ITEMS. |
+ | |||
+ | In order for your post to show up correctly, you need to: |
||
+ | >> Use FIVE equal-signs for the Title's heading level. eg.: ===== my post ===== |
||
+ | >> Use two slashes // and FOUR tilde's to insert your signature at the end of your post: //~~~~ |
||
--> |
--> |
||
<!----------------------------------------------> |
<!----------------------------------------------> |
||
− | <!------------- |
+ | <!------------- Equipment Status ----------------> |
− | ===== |
+ | ===== GCA Autostep and 6300 October Maintenance ===== |
+ | The vendor will be here October 25 until October 28 to service both steppers. The Autostep will be Monday thru Wednesday from 8am until 6pm. The 6300 will be serviced on Thursday from 8am until 6pm. |
||
− | The campus cooling water system is back up and the humidity levels are back to normal. The lab is open for use. |
||
− | + | [[User:Silva|Silva]] 08:39, 12 October 2021 (PDT) |
|
− | ===== |
+ | ===== Oxford ICP Installed ===== |
+ | A new ICP etcher for III-V etches (GaAs, InP, GaN) has been installed: [[Oxford_ICP_Etcher_(PlasmaPro_100_Cobra)]] |
||
− | The top side microscope will not move. Working with vendor to correct the problem. |
||
⚫ | |||
+ | Contact [[Tony_Bosch | the supervisor]] for training. |
||
− | ===== PECVD#1: Software Upgrade ===== |
||
+ | // [[User:John d|John d]] 08:00, 30 September 2021 (PDT) |
||
− | We are going to upgrade the computer and software on PECVD#1 in 2–3 weeks. The tool will be down for three to five days. Once the upgrade is complete, everyone will need to be retrained on the new software. You should start planning accordingly, if you use this tool. We will send out an email when we know the exact dates. |
||
⚫ | |||
− | ===== |
+ | ===== New COVID Protocols ===== |
+ | All facility users and visitors are now required to have masks on while indoors in shared spaces. This includes shared offices, hallways/corridors, and all shared laboratory spaces. Masks will be worn in all laboratories at all times and in all shared office spaces at all times. |
||
− | AFM head has been returned from service, system is up for use. Please notify NanoFab@ece.ucsb.edu if you experience any problems with it. |
||
⚫ | |||
+ | This direction applies to all vaccinated and non-vaccinated persons. |
||
− | ===== RIE#5: SiCl4 Issue ===== |
||
− | We have a flow rate problem on the SiCl4 gas line. You can only flow the SiCl4 for 5 minutes and then you have to wait 5 minutes before you flow it again. So in order to to do a 10 minute Etch you will have to do it in three steps flow 5 mi, wait 5mi, then flow 5min. |
||
⚫ | |||
+ | Outdoor policies remain unchanged |
||
− | ===== Solvent Bench Bay 7 - Heated Bath ===== |
||
− | We have disabled the auto refill due to a high water level. Please use the manual fill and a manual drain button at the center top of the head case. Users of the bath might need to fill or drain as you insert/remove your beakers. Please be careful with other user's beakers. |
||
− | // [[User:John d|John d]] 17:18, 6 June 2018 (PDT) |
||
+ | Surgical style masks or KN95 masks are appropriate for cleanroom use. Cloth masks may be used in non-cleanroom spaces. |
||
⚫ | |||
+ | |||
+ | See the full policies at [[COVID-19_User_Policies]] |
||
+ | |||
⚫ | |||
+ | |||
+ | ===== Weekly Testing strongly urged for UCSB Students/Staff ===== |
||
+ | Free weekly COVID testing is available to UCSB Staff, Faculty and Students. UCSB employees are strongly urged to sign up for weekly testing, which takes only minutes, is administered on-campus and is free of charge. |
||
+ | |||
+ | Weekly recurring appointments can be made at the Student Health website: |
||
+ | * Log on to the [https://studenthealthoc.sa.ucsb.edu/login_dualauthentication.aspx '''UCSB Testing Patient Portal'''] using your UCSB NetID and password. |
||
+ | |||
+ | The Chancellor's [https://chancellor.ucsb.edu/memos/2020-10-15-recommended-covid-19-asymptomatic-campus-testing-program-faculty-staff-and memo to campus with details can be found here]. |
||
⚫ | |||
+ | |||
+ | ===== NanoFab COVID Protocols ===== |
||
+ | |||
+ | ''The most recent COVID Protocols can be found at '''[[COVID-19_User_Policies]]'''.'' |
||
+ | |||
⚫ | |||
+ | |||
+ | |||
⚫ | |||
<!----------------------------------------------> |
<!----------------------------------------------> |
||
<endfeed /> |
<endfeed /> |
||
Line 44: | Line 64: | ||
====== HOW TO ADD NEWS ITEMS ====== |
====== HOW TO ADD NEWS ITEMS ====== |
||
+ | * You can copy/paste the example below for a new news item. |
||
* Use level 5 heading for each item (5 equal signs surrounding the title) - they will show up as separate RSS items this way. (This looks best on the Wiki homepage) |
* Use level 5 heading for each item (5 equal signs surrounding the title) - they will show up as separate RSS items this way. (This looks best on the Wiki homepage) |
||
* You must add a user signature at the end of each post via four tildes: ~~~~. Required for the RSS plugin to determine the timestamp, or else post goes to the end of the RSS feed. |
* You must add a user signature at the end of each post via four tildes: ~~~~. Required for the RSS plugin to determine the timestamp, or else post goes to the end of the RSS feed. |
||
Line 49: | Line 70: | ||
* Optional: After saving the page, delete the name after the two dashes "--" and delete the "[[(talk)...]]" link. |
* Optional: After saving the page, delete the name after the two dashes "--" and delete the "[[(talk)...]]" link. |
||
* Please use "There are no announcements at this time." if the announcements are empty. |
* Please use "There are no announcements at this time." if the announcements are empty. |
||
+ | |||
+ | * URL to the RSS feed via FeedBurner (for Samsung display): http://feeds.feedburner.com/UCSBNanofab-Announcements?format=xml |
||
+ | * URL to the RSS feed directly from Wiki: https://www.nanotech.ucsb.edu/wiki/index.php?title=Template:Announcements&action=feed&feed=rss |
||
Line 57: | Line 81: | ||
// ~~~~ |
// ~~~~ |
||
− | (end of example) |
+ | ************* (end of example) ************** |
The ~~~~ will be replaced with your username & timestamp after you submit the post. |
The ~~~~ will be replaced with your username & timestamp after you submit the post. |
||
----------------------------------------------> |
----------------------------------------------> |
Revision as of 17:01, 21 October 2021
Equipment Status
GCA Autostep and 6300 October Maintenance
The vendor will be here October 25 until October 28 to service both steppers. The Autostep will be Monday thru Wednesday from 8am until 6pm. The 6300 will be serviced on Thursday from 8am until 6pm. Silva 08:39, 12 October 2021 (PDT)
Oxford ICP Installed
A new ICP etcher for III-V etches (GaAs, InP, GaN) has been installed: Oxford_ICP_Etcher_(PlasmaPro_100_Cobra)
Contact the supervisor for training. // John d 08:00, 30 September 2021 (PDT)
New COVID Protocols
All facility users and visitors are now required to have masks on while indoors in shared spaces. This includes shared offices, hallways/corridors, and all shared laboratory spaces. Masks will be worn in all laboratories at all times and in all shared office spaces at all times.
This direction applies to all vaccinated and non-vaccinated persons.
Outdoor policies remain unchanged
Surgical style masks or KN95 masks are appropriate for cleanroom use. Cloth masks may be used in non-cleanroom spaces.
See the full policies at COVID-19_User_Policies
// Hopkins a 08:14, 6 August 2021 (PDT)
Weekly Testing strongly urged for UCSB Students/Staff
Free weekly COVID testing is available to UCSB Staff, Faculty and Students. UCSB employees are strongly urged to sign up for weekly testing, which takes only minutes, is administered on-campus and is free of charge.
Weekly recurring appointments can be made at the Student Health website:
- Log on to the UCSB Testing Patient Portal using your UCSB NetID and password.
The Chancellor's memo to campus with details can be found here. // John d 06:20, 16 November 2020 (PST)
NanoFab COVID Protocols
The most recent COVID Protocols can be found at COVID-19_User_Policies.
// John d 15:00, 19 July 2020 (PDT)