Difference between revisions of "Step Profilometer (KLA Tencor P-7)"
Jump to navigation
Jump to search
(link to photo KLA-Tencor-P7_Photo.JPG) |
Millerski w (talk | contribs) (Updated SOP) |
||
(6 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | {{ |
+ | {{tool2|{{PAGENAME}} |
|picture=KLA-Tencor-P7_Photo.JPG |
|picture=KLA-Tencor-P7_Photo.JPG |
||
|type = Inspection, Test and Characterization |
|type = Inspection, Test and Characterization |
||
− | |super= |
+ | |super= Bill Millerski |
+ | |super2= Aidan Hopkins |
||
|phone=(805)839-3918x210 |
|phone=(805)839-3918x210 |
||
|location=Bay 4 |
|location=Bay 4 |
||
− | |email=lingg_b@ucsb.edu |
||
|description = Surface Profilometer |
|description = Surface Profilometer |
||
|manufacturer = KLA Tencor |
|manufacturer = KLA Tencor |
||
|materials = |
|materials = |
||
}} |
}} |
||
− | == |
+ | ==About== |
+ | The KLA-Tencor P7 profilometer is a stylus profilometer that drags a stylus across the wafer surface with controlled pressure, aligned via microcope, and measures the step-heights of surface features during the measurement. The system has a motor-controlled stage for X/Y/Rotation, and is typically used to measure step heights in single areas on various sample sizes frmo small pieces to 4-inch wafers. It can be programmed to scan multiple locations on a single wafer or 3D areas topography. |
||
− | The KLA Tencor info will be here |
||
==Detailed Specifications== |
==Detailed Specifications== |
||
− | *More info to go here |
||
+ | *Probe Tip has a 2um radius and a 60 degree angle |
||
⚫ | |||
+ | *Maximum wafer size: ____ |
||
⚫ | |||
+ | *1D Profile and 2D Raster Scanning |
||
+ | *Lateral Resolution: _____ |
||
+ | *Height Resolution: _____ |
||
+ | |||
⚫ | |||
+ | |||
⚫ | |||
+ | *[[KLA Tencor P7 - Saving Profile Data|Saving+Extracting Profile Data]] |
Latest revision as of 15:09, 30 October 2023
|
About
The KLA-Tencor P7 profilometer is a stylus profilometer that drags a stylus across the wafer surface with controlled pressure, aligned via microcope, and measures the step-heights of surface features during the measurement. The system has a motor-controlled stage for X/Y/Rotation, and is typically used to measure step heights in single areas on various sample sizes frmo small pieces to 4-inch wafers. It can be programmed to scan multiple locations on a single wafer or 3D areas topography.
Detailed Specifications
- Probe Tip has a 2um radius and a 60 degree angle
- Maximum wafer size: ____
- 1D Profile and 2D Raster Scanning
- Lateral Resolution: _____
- Height Resolution: _____