User contributions
Jump to navigation
Jump to search
- 17:09, 9 April 2024 diff hist +93 ICP Etching Recipes →Through Silicon Via (TSV) etch (DSEiii): no-wax proces sis acceptable current Tag: Visual edit
- 17:00, 9 April 2024 diff hist +10 m Stepper 3 (ASML DUV) →Operating Procedures current Tag: Visual edit
- 23:06, 4 April 2024 diff hist -31 Step Profilometer (KLA Tencor P-7) updated specs current Tag: Visual edit
- 22:44, 4 April 2024 diff hist -10 m Calculators + Utilities →CAD Files & Templates current Tag: Visual edit
- 22:41, 4 April 2024 diff hist +73 N File:Contact-AlignMarks Vernier DemisDJohn v4.oas Contact Alignment Marks redesigned by Demis D. John - OASIS current
- 22:41, 4 April 2024 diff hist +71 N File:Contact-AlignMarks Vernier DemisDJohn v4.gds Contact Alignment Marks redesigned by Demis D. John - GDS current
- 22:37, 4 April 2024 diff hist 0 File:Contact-AlignMarks Vernier DemisDJohn v3 Screenshot.png.png John d uploaded a new version of File:Contact-AlignMarks Vernier DemisDJohn v3 Screenshot.png.png current
- 22:36, 4 April 2024 diff hist +341 m Calculators + Utilities →General CAD files for Litho Tag: Visual edit
- 21:25, 4 April 2024 diff hist +60 m MLA150 - CAD Files and Templates →Alignment Marks current Tag: Visual edit
- 21:22, 4 April 2024 diff hist +1 m Calculators + Utilities →General CAD files for Litho Tag: Visual edit
- 00:00, 4 April 2024 diff hist +193 Calculators + Utilities →General CAD files for Litho: screenshot of Contact-AlignMarks_Vernier_DemisDJohn_v3.oas Tag: Visual edit: Switched
- 23:57, 3 April 2024 diff hist +58 N File:Contact-AlignMarks Vernier DemisDJohn v3 Screenshot.png.png
- 23:53, 3 April 2024 diff hist +34 m Calculators + Utilities →General CAD files for Litho: author credits for contact mark Tag: Visual edit
- 23:53, 3 April 2024 diff hist +78 Calculators + Utilities →General CAD files for Litho: updated contact mark to v3, in OASIS and GDS format Tag: Visual edit
- 23:50, 3 April 2024 diff hist +71 N File:Contact-AlignMarks Vernier DemisDJohn v3.gds Contact Alignment Marks redesigned by Demis D. John - GDS current
- 23:49, 3 April 2024 diff hist +73 N File:Contact-AlignMarks Vernier DemisDJohn v3.oas Contact Alignment Marks redesigned by Demis D. John - OASIS current
- 20:29, 3 April 2024 diff hist +145 Calculators + Utilities →General CAD files for Litho: added contact alignment mark Tag: Visual edit
- 17:09, 1 April 2024 diff hist +806 Nanofab Job Postings added SUmmer '24 etch and dep internsip positions to OPEN positions current Tag: Visual edit
- 10:34, 1 April 2024 diff hist +997 Wet Etching Recipes →Gold Plating Bench (Technic SEMCON 1000): added basic recipe steps for seed/plate/etch current Tag: Visual edit
- 10:27, 1 April 2024 diff hist +177 Gold Plating Bench link to recipes page current Tag: Visual edit
- 10:27, 1 April 2024 diff hist +28 Wet Etching Recipes →Gold Plating: changed name to include mfg/model Tag: Visual edit
- 17:03, 21 March 2024 diff hist +58 Stepper Recipes →Negative Resist (ASML DUV): UVN dev time current Tag: Visual edit
- 15:05, 20 March 2024 diff hist +149 MLA150 - Troubleshooting →Causes: added OAF driving off wafer current Tag: Visual edit
- 15:04, 20 March 2024 diff hist +172 Direct-Write Lithography Recipes →Maskless Aligner (Heidelberg MLA150): link to Troubleshooting/OOFocus section current Tag: Visual edit
- 17:27, 14 March 2024 diff hist +429 Direct-Write Lithography Recipes →Maskless Aligner (Heidelberg MLA150): added FEM comment Tag: Visual edit
- 17:17, 14 March 2024 diff hist -29 Direct-Write Lithography Recipes →Greyscale Lithography (MLA150): deleted Flood Expose column Tag: Visual edit
- 03:27, 13 March 2024 diff hist -1,261 Stepper 3 (ASML DUV) removed Wiki-hosted ASML procedures, linked to gDrive procedures (access restricted) Tag: Visual edit
- 16:16, 12 March 2024 diff hist +62 Nanofab Job Postings →Process/Wafer Fab Engineer Level 3 (Staff position): not reviewing apps Tag: Visual edit
- 16:13, 12 March 2024 diff hist +48 Main Page link to Job Postings current Tag: Visual edit
- 15:47, 12 March 2024 diff hist -1,402 Template:Announcements deleted duplicates and old >2wk old annc
- 09:54, 11 March 2024 diff hist +271 ICP Etching Recipes →Through Silicon Via (TSV) etch (DSEiii): added note on TSV rocess - discuss with staff before running Tag: Visual edit
- 09:42, 11 March 2024 diff hist +9 m Staff List →Process Group current Tag: Visual edit
- 09:42, 11 March 2024 diff hist +75 Staff List →Process Group: added mission statement Tag: Visual edit
- 10:19, 9 March 2024 diff hist -1 IBD: Calibrating Optical Thickness Corrected 1050/1100 FP correction current Tag: Visual edit
- 12:54, 7 March 2024 diff hist +861 Nanofab Job Postings added R&D2 pos Tag: Visual edit
- 11:15, 7 March 2024 diff hist +526 Tube Furnace (Tystar 8300) process limits added current Tag: Visual edit
- 18:43, 5 March 2024 diff hist 0 File:Oxford Etcher - InP Ridge Etch using Oxford PlasmaPro 100 Cobra - 2021-09-08.pdf John d uploaded a new version of File:Oxford Etcher - InP Ridge Etch using Oxford PlasmaPro 100 Cobra - 2021-09-08.pdf current
- 18:35, 5 March 2024 diff hist 0 File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf John d uploaded a new version of File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf current
- 18:33, 5 March 2024 diff hist 0 File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf John d uploaded a new version of File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf
- 18:22, 5 March 2024 diff hist 0 File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf John d uploaded a new version of File:Oxford Etcher - InP Grating Etch at 20 C - Oxford Cobra 300 2021-08-26.pdf
- 16:25, 4 March 2024 diff hist +47 m Packaging Recipes →Dicing Saw Recipes (ADT 7100) current
- 13:55, 1 March 2024 diff hist +148 Oxygen Plasma System Recipes →N2/O2 Recipes: note that wafers get hotter than recipe name indicates. current Tag: Visual edit
- 12:07, 1 March 2024 diff hist +3 Suss Aligners (SUSS MJB-3) →IR Aligner: removed hammamatsu current Tag: Visual edit
- 12:06, 1 March 2024 diff hist +285 Suss Aligners (SUSS MJB-3) →IR Aligner: added photo of front-to-back IR camera alignment inspection Tag: Visual edit
- 12:04, 1 March 2024 diff hist +81 N File:IR Alignment check 01 - crop.png current
- 11:52, 1 March 2024 diff hist +85 Tool List →Optical Microscopy: link to MJB-IR IR scope current Tag: Visual edit
- 11:30, 1 March 2024 diff hist +51 N File:OlympusDSX1000.jpg New photo with non-proprietary image. current
- 21:08, 29 February 2024 diff hist +19 m Field Emission SEM 2 (JEOL IT800SHL) current Tag: Visual edit
- 21:07, 29 February 2024 diff hist +419 SEM 1 (JEOL IT800SHL) →Operating Procedures: linked to CalTech stuf correction vid with tops current Tag: Visual edit
- 13:46, 29 February 2024 diff hist +132 Oxygen Plasma System Recipes →N2/O2 effect on Gold contacts & Substrate Temperature: minor additions to clarify gold optical absorption Tag: Visual edit