User contributions
Jump to navigation
Jump to search
- 09:43, 27 May 2020 diff hist +61 N Operating Instructions Created page with "Advanced Vacuum PECVD.pdf" current Tag: Visual edit
- 09:40, 27 May 2020 diff hist +4 PECVD 2 (Advanced Vacuum) →Documentation Tag: Visual edit
- 09:36, 27 May 2020 diff hist 0 N File:Advanced Vacuum PECVD.pdf current
- 09:31, 27 May 2020 diff hist +1 PECVD 1 (PlasmaTherm 790) →Documentation Tag: Visual edit
- 08:50, 8 May 2020 diff hist -151 PECVD Recipes →ICP-PECVD (Unaxis VLR) Tag: Visual edit
- 17:16, 22 April 2020 diff hist +1 PECVD Recipes →SiN deposition (PECVD #1)
- 17:16, 22 April 2020 diff hist -29 PECVD Recipes →SiN deposition (PECVD #1)
- 17:08, 22 April 2020 diff hist -37 PECVD Recipes →SiO2 deposition (PECVD #1)
- 16:57, 22 April 2020 diff hist +57 PECVD1 Wafer Coating Process Tag: Visual edit
- 16:54, 22 April 2020 diff hist +18 Wafer Coating Process Traveler current Tag: Visual edit
- 16:53, 22 April 2020 diff hist -18 Wafer Coating Process Traveler link to recipes Tag: Visual edit
- 16:52, 22 April 2020 diff hist +54 Wafer Coating Process Traveler Tag: Visual edit
- 16:50, 22 April 2020 diff hist +1,475 Wafer Coating Process Traveler →STD SiO2 Tag: Visual edit
- 16:48, 22 April 2020 diff hist -8 Wafer Coating Process Traveler →STD SiO2 Tag: Visual edit
- 16:47, 22 April 2020 diff hist +724 Wafer Coating Process Traveler →Standard oxide deposition Tag: Visual edit
- 16:43, 22 April 2020 diff hist -7 Wafer Coating Process Traveler →STD LS Nitride2 at 300C Tag: Visual edit
- 16:42, 22 April 2020 diff hist -3,906 Wafer Coating Process Traveler Replaced content with "There are three standard recipes : STD SiO2, STD Nitride2, and STD LS Nitride2 at 300C. Instructions bellow explain how to run each of the recipes ( seasoning, deposition,..." Tags: Replaced Visual edit
- 16:38, 22 April 2020 diff hist +4 PECVD 2 (Advanced Vacuum) →Documentation Tag: Visual edit
- 16:38, 22 April 2020 diff hist -9 PECVD 2 (Advanced Vacuum) →Documentation Tag: Visual edit
- 16:37, 22 April 2020 diff hist +78 PECVD 2 (Advanced Vacuum) →Documentation Tag: Visual edit
- 16:36, 22 April 2020 diff hist +93 PECVD 2 (Advanced Vacuum) →Documentation Tag: Visual edit
- 16:35, 22 April 2020 diff hist +21 PECVD 2 (Advanced Vacuum) Tag: Visual edit
- 16:33, 22 April 2020 diff hist +11 PECVD1 Wafer Coating Process SiN and SiO2 depositions Tag: Visual edit
- 16:31, 22 April 2020 diff hist -13 PECVD1 Wafer Coating Process →PECVD#1 SiN @250C Tag: Visual edit
- 16:30, 22 April 2020 diff hist +49 PECVD1 Wafer Coating Process →PECVD#1 SiN @250C Tag: Visual edit
- 16:28, 22 April 2020 diff hist +4 PECVD1 Wafer Coating Process Tag: Visual edit
- 16:26, 22 April 2020 diff hist +16 PECVD1 Wafer Coating Process
- 16:23, 22 April 2020 diff hist -897 PECVD1 Wafer Coating Process Tag: Visual edit
- 16:21, 22 April 2020 diff hist +137 PECVD 1 (PlasmaTherm 790) →Documentation Tag: Visual edit
- 16:19, 22 April 2020 diff hist +112 PECVD1 Wafer Coating Process →SiO2 @250C Tag: Visual edit
- 16:18, 22 April 2020 diff hist +18 PECVD1 Wafer Coating Process Tag: Visual edit
- 16:14, 22 April 2020 diff hist +783 PECVD1 Wafer Coating Process Tag: Visual edit
- 16:09, 22 April 2020 diff hist -217 PECVD1 Wafer Coating Process →SiN @250C Tag: Visual edit
- 15:59, 22 April 2020 diff hist -6 ICP-PECVD (Unaxis VLR) →Documentation Tag: Visual edit
- 13:27, 22 April 2020 diff hist +11 ICP-PECVD (Unaxis VLR) →Documentation Tag: Visual edit
- 13:25, 22 April 2020 diff hist +1 Wafer Coating Process Traveler →Unaxis deposition - SiO2 LDR film @250°C Tag: Visual edit
- 13:24, 22 April 2020 diff hist +1 Wafer Coating Process Traveler →Unaxis deposition - 300nm SiO2 HDR film @250°C Tag: Visual edit
- 13:24, 22 April 2020 diff hist +1 Wafer Coating Process Traveler →Unaxis deposition - 300nm SiN film @250°C Tag: Visual edit
- 13:24, 22 April 2020 diff hist +28 Wafer Coating Process Traveler →Unaxis deposition - 300nm SiN film @250°C Tag: Visual edit
- 11:33, 22 April 2020 diff hist -13 ICP-PECVD (Unaxis VLR) →Documentation Tag: Visual edit
- 11:33, 22 April 2020 diff hist -131 ICP-PECVD (Unaxis VLR) →Documentation Tag: Visual edit
- 11:31, 22 April 2020 diff hist -988 Wafer Scanning process Traveler wafers scanning procedure current Tag: Visual edit
- 11:29, 22 April 2020 diff hist -744 Wafer scanning process traveler →Scan before process calibration Tag: Visual edit
- 11:25, 22 April 2020 diff hist -316 Wafer Scanning process Traveler →Wafers to Use Tag: Visual edit
- 11:23, 22 April 2020 diff hist +454 Wafer scanning process traveler →Wafers to Use Tag: Visual edit
- 11:14, 22 April 2020 diff hist -917 Wafer Coating Process Traveler →Unaxis deposition - SiO2 LDR film @250°C Tag: Visual edit
- 11:10, 22 April 2020 diff hist +766 Wafer Coating Process Traveler →Unaxis deposition - SiO2 LDR film @250°C: correction on Unaxis recipes Tag: Visual edit
- 11:02, 22 April 2020 diff hist -4 Wafer Coating Process Traveler →Unaxis deposition - SiO2 LDR film @250°C Tag: Visual edit
- 10:57, 22 April 2020 diff hist +97 Wafer Coating Process Traveler →Unaxis deposition - SiO2 LDR film @250°C Tag: Visual edit
- 10:37, 22 April 2020 diff hist +151 PECVD Recipes →Historical Particulate Data