==CdZnTe Etching (RIE 2)== | ==CdZnTe Etching (RIE 2)== | ||
− | *[ | + | *[//wiki.nanotech.ucsb.edu/w/images/f/f5/11-CZT_etching-1.pdf CdZnTe Etch Recipes - CH<sub>4</sub>-H<sub>2</sub>-Ar] |
==ZnS Etching (RIE 2)== | ==ZnS Etching (RIE 2)== | ||
− | *[ | + | *[//wiki.nanotech.ucsb.edu/w/images/b/b4/ZnS_Plasma_Etch-1.pdf ZnS Etch Recipe - CH<sub>4</sub>-H<sub>2</sub>-Ar] |
==ITO Etching (RIE 2)== | ==ITO Etching (RIE 2)== | ||
− | *[ | + | *[//wiki.nanotech.ucsb.edu/w/images/f/f4/RIE2-ITO-Etch-MHA-Plasma-RevA.pdf ITO Etch Recipes - CH<sub>4</sub>-H<sub>2</sub>-Ar] |
==InP-InGaAsP-InGaAlAs Etching (RIE 2)== | ==InP-InGaAsP-InGaAlAs Etching (RIE 2)== | ||
− | *[ | + | *[//wiki.nanotech.ucsb.edu/w/images/6/6f/RIE2-InGaAs-InP-InAlAs-Etch-Plasma-RIE-RevA.pdf InP-InGaAsP-InAlGaAs Etch Recipes - CH<sub>4</sub>-H<sub>2</sub>-Ar] |
=[[RIE 3 (MRC)]] = | =[[RIE 3 (MRC)]] = | ||
==SiO<sub>2</sub> Etching (RIE 3)== | ==SiO<sub>2</sub> Etching (RIE 3)== | ||
− | *[ | + | *[//wiki.nanotech.ucsb.edu/w/images/2/2f/SiO2-Etch-Recipe-using-RIE-3-a.pdf SiO<sub>2</sub> Etch Recipe with a very low surface damage - CHF<sub>3] |
==SiN<sub>x</sub> Etching (RIE 3)== | ==SiN<sub>x</sub> Etching (RIE 3)== | ||
− | *[ | + | *[//wiki.nanotech.ucsb.edu/w/images/9/98/51-SiNx-Etch-Recipe-using-RIE3.pdf SiN<sub>x</sub> Etch Recipe with a very low surface damage - CHF<sub>3] |
=[[RIE 5 (PlasmaTherm)]] = | =[[RIE 5 (PlasmaTherm)]] = | ||
==AlGaAs\GaAs Etching (RIE 5)== | ==AlGaAs\GaAs Etching (RIE 5)== | ||
− | *[ | + | *[//wiki.nanotech.ucsb.edu/w/images/b/b5/13-GaAs-AlGaAs_Etching-RIE-5.pdf GaAs\AlGaAs Etch Recipes - BCl<sub>3</sub>-SiCl<sub>4</sub>] |
==GaN Etching (RIE 5)== | ==GaN Etching (RIE 5)== | ||
− | *[ | + | *[//wiki.nanotech.ucsb.edu/w/images/c/cb/08-Plasma_Etching_of_GaN-RIE5.pdf GaN Etch Recipes - Cl<sub>2</sub>-BCl<sub>3</sub>-Ar] |
− | == Photoresist and ARC == | + | == Photoresist and ARC (RIE 5) == |
− | === DUV42P (AR2) etching | + | === DUV42P (AR2) etching === |
* O2 = 20sccm // Pressure = 10mT // RF = 100W // Time = 40 sec | * O2 = 20sccm // Pressure = 10mT // RF = 100W // Time = 40 sec | ||
* No need to pump/purge, can etch right away. | * No need to pump/purge, can etch right away. | ||
* No helium cooling, Run in manual mode. | * No helium cooling, Run in manual mode. |
Latest revision as of 10:02, 14 June 2021
Back to Dry Etching Recipes.
RIE 2 (MRC)
CdZnTe Etching (RIE 2)
ZnS Etching (RIE 2)
ITO Etching (RIE 2)
InP-InGaAsP-InGaAlAs Etching (RIE 2)
RIE 3 (MRC)
SiO2 Etching (RIE 3)
SiNx Etching (RIE 3)
RIE 5 (PlasmaTherm)
AlGaAs\GaAs Etching (RIE 5)
GaN Etching (RIE 5)
Photoresist and ARC (RIE 5)
DUV42P (AR2) etching
- O2 = 20sccm // Pressure = 10mT // RF = 100W // Time = 40 sec
- No need to pump/purge, can etch right away.
- No helium cooling, Run in manual mode.