PECVD Recipes
Revision as of 14:11, 9 February 2018 by Biljana (talk | contribs) (→Low-Stress SiN deposition (PECVD #2))
Back to Vacuum Deposition Recipes.
PECVD 1 (PlasmaTherm 790)
- Particulates (Gain4) in PECVD#1 2015
- Particulates (Gain4) in PECVD#1 2016
- Particulates (Gain4) in PECVD#1 2017
- Particulates (Gain4 and Gain2) in PECVD#1 films 2017
SiN deposition (PECVD #1)
- SiN Standard Recipe
- SiN 100nm Data 2014
- SiN 100nm Data 2015
- SiN 100nm Data 2016
- SiN 100nm Data 2017
- SiN 300nm Data 2017
- SiN 100 nm Thickness uniformity 2014
- SiN 100 nm Thickness uniformity 2015
- SiN 100 nm Thickness uniformity 2016
- SiN 100 nm Thickness uniformity 2017
- SiN 300nm Thickness uniformity 2017
SiO2 deposition (PECVD #1)
- SiO2 Standard Recipe
- SiO2 100nm Data 2014
- SiO2 100nm Data 2015
- SiO2 100nm Data 2016
- SiO2 100nm Data 2017
- SiO2 300nm Data 2017
- SiO2 100nm Thickness uniformity 2014
- SiO2 100 nm Thickness uniformity 2015
- SiO2 100 nmThickness uniformity 2016
- SiO2 100nm Thickness uniformity 2017
- SiO2 300nm Thickness uniformity 2017
OTHER recipes: Low-Stress (LS) SiN and SiOxNy deposition (PECVD #1)
- LS SiN Standard Recipe
- LS SiN Data 2014
- LS SiN 1000A Thickness uniformity 2014
- SiOxNy Standard Recipe
- SiOxNy Data 2014
- SiOxNy1000A Thickness uniformity 2014
PECVD 2 (Advanced Vacuum)
- Particulates (Gain4) in PECVD#2 2015
- Particulates (Gain4) in PECVD#2 2016
- Particulates (Gain4) in PECVD#2 2017
- Particulates (Gain4 and Gain2) in PECVD#2 films 2017
SiO2 deposition (PECVD #2)
- Oxide Standard Recipe
- Oxide Data 2014
- Oxide Data 2015
- Oxide data 2016
- Oxide Data 2017
- Oxide Thickness Uniformity 2014
- Oxide Thickness Uniformity 2015
- Oxide Thickness Uniformity 2016
- Oxide Thickness Uniformity 2017
SiN deposition (PECVD #2)
- Nitride2 Standard Recipe
- Nitride2 Data 2014
- Nitride2 Data 2015
- Nitride2 Data 2016
- Nitride2 Data 2017
- Nitride2 Thickness Uniformity 2014
- Nitride2 Thickness Uniformity 2015
- Nitride2 Thickness Uniformity 2016
- Nitride2 Thickness Uniformity 2017
- SiNx Film Stress vs LF and HF Duration Time, and Gas Flowing-rate
Low-Stress SiN deposition (PECVD #2)
Low-Stress SilIcon Nitride (< 100 MPa)
- LS Nitride2 Standard Recipe
- LS Nitride2 Data 2014
- LS Nitride2 Data 2015
- LS Nitride2 Data 2016
- LS Nitride2 Data 2017
- LSNitride Data 2018
- LS Nitride2 Thickness Uniformity 2014
- LS Nitride2 Thickness Uniformity 2015
- LS Nitride2 Thickness Uniformity 2016
- LS Nitride2 Thickness Uniformity 2017
Amorphous-Si deposition (PECVD #2)
ICP-PECVD (Unaxis VLR)
SiN deposition (Unaxis VLR)
SiN (2% SiH4)
SiN (2% SiH4 - No-Ar)
SiN (2% SiH4 - No-Ar - Extra N2)
50° (pinholes) | 100° (pinholes) | 250° |
---|---|---|
SiN (100% SiH4 )
50° (pinholes) | 100° (pinholes) | 250° |
---|---|---|
SiO2 deposition (Unaxis VLR)
SiO2 (2% SiH4)
50° | 100° | 250° |
---|---|---|
SiO2 (2% SiH4 - No Ar)
50° | 100° | 250° |
---|---|---|
SiO2 (100% SiH4 HDR)
50° | 100° | 250° |
---|---|---|
SiO2 (100% SiH4 LDR)
50° | 100° | 250° |
---|---|---|
Amorphous Si (100%SiH4 Ar He)
90° | 250° |
---|---|