+ | [https://wiki.nanotech.ucsb.edu/w/index.php?title=Tool_List#Thermal_Processing See the full list of Thermal Processing tools here.] |
||
− | {{tool |
||
+ | {| class="wikitable sortable" |
||
− | |picture=Photo_of_the_tool_01.jpg |
||
+ | |+List of all lab ovens and capabilities/uses |
||
− | |type = Thermal Processing |
||
+ | !Oven Name + Link |
||
− | |recipe = Thermal Processing |
||
+ | !Temperature Range/Capabilities |
||
− | |location = various |
||
+ | !Programmable |
||
− | |description = Lab ovens |
||
+ | !Gases |
||
− | |manufacturer = various |
||
+ | !Vacuum/Pressure Range |
||
⚫ | |||
+ | !Typical Uses |
||
+ | !SignupMonkey Reservation |
||
+ | |- |
||
+ | |[[Ovens 1, 2 & 3 (Labline)|Oven 1]] |
||
+ | | |
||
+ | * Typically 95°C |
||
+ | * Passive Cooling |
||
+ | |No, single temperature. |
||
+ | |N/A |
||
+ | |Atmosphere only |
||
+ | |Drying glassware, general baking. |
||
+ | |No. Users may change temperature. |
||
+ | |- |
||
+ | |[[Ovens 1, 2 & 3 (Labline)|Oven 2]] |
||
+ | | |
||
+ | * Typically 100°C |
||
+ | * Passive Cooling |
||
+ | |No, single temperature. |
||
+ | |N/A |
||
+ | |Atmosphere only |
||
+ | |Drying glassware, general baking. |
||
+ | |No. Users may change temperature. |
||
+ | |- |
||
+ | |[[Oven 4 (Thermo-Fisher HeraTherm)|Oven 4: HeraTherm Oven]] |
||
+ | | |
||
+ | * Max. Temp = 330°C |
||
+ | * Passive Cooling, optional vent to atmosphere for speed. |
||
+ | | |
||
+ | * Multi-step programmable |
||
+ | * Ramp Rate: only low/med/high (not numeric ramp rate). |
||
+ | * Gas flow not programmable |
||
+ | | |
||
+ | * N2 (manual flow valve) |
||
+ | * Atmosphere Purge |
||
+ | |Atmosphere only |
||
+ | |Bonding, BCB/Polymer curing. |
||
+ | |[https://signupmonkey.ece.ucsb.edu/cgi-bin/users/browse.cgi?tool_ID=68 Sign Up For This Tool] |
||
+ | (Also log in logbook) |
||
+ | |- |
||
+ | |[[High Temp Oven (Blue M)|Blue-M Oven]] |
||
+ | | |
||
+ | * Max. temp. 350°C |
||
+ | * Passive Cooling |
||
+ | | |
||
+ | * Yes, fully programmable up to 2 stages. |
||
+ | * Gas flow not programmable |
||
+ | | |
||
+ | * N2 (manual flow setting) |
||
+ | |Atmosphere only |
||
+ | |BCB/Polymer curing. |
||
+ | |[http://signupmonkey.ece.ucsb.edu/cgi-bin/users/browse.cgi?tool_ID=56 Sign Up For This Tool] |
||
+ | |- |
||
+ | |[[Vacuum Oven (YES)|YES Vacuum Oven]] |
||
+ | | |
||
+ | * Max. Temp 250°C |
||
+ | * Passive Cooling |
||
+ | |''Controller non-operational'' |
||
+ | | |
||
+ | * N2 |
||
+ | |Atmosphere only |
||
+ | | |
||
+ | |No. First-come first-serve. |
||
⚫ |
Revision as of 12:50, 4 September 2021
See the full list of Thermal Processing tools here.
Oven Name + Link | Temperature Range/Capabilities | Programmable | Gases | Vacuum/Pressure Range | Typical Uses | SignupMonkey Reservation |
---|---|---|---|---|---|---|
Oven 1 |
|
No, single temperature. | N/A | Atmosphere only | Drying glassware, general baking. | No. Users may change temperature. |
Oven 2 |
|
No, single temperature. | N/A | Atmosphere only | Drying glassware, general baking. | No. Users may change temperature. |
Oven 4: HeraTherm Oven |
|
|
|
Atmosphere only | Bonding, BCB/Polymer curing. | Sign Up For This Tool
(Also log in logbook) |
Blue-M Oven |
|
|
|
Atmosphere only | BCB/Polymer curing. | Sign Up For This Tool |
YES Vacuum Oven |
|
Controller non-operational |
|
Atmosphere only | No. First-come first-serve. |