Line 3: | Line 3: | ||
=[[PECVD 1 (PlasmaTherm 790)]]= |
=[[PECVD 1 (PlasmaTherm 790)]]= |
||
+ | |||
+ | === [https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=1270764394 PECVD 1 Plots] === |
||
==SiO<sub>2</sub> [PECVD 1]== |
==SiO<sub>2</sub> [PECVD 1]== |
||
Line 13: | Line 15: | ||
===Historical Data=== |
===Historical Data=== |
||
− | SiO<sub>2</sub> [PECVD 1] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=1503619544 SiO<sub>2</sub><nowiki> [PECVD 1] Historical Data</nowiki>] |
− | <br /> |
||
==Si<sub>3</sub>N<sub>4</sub> [PECVD 1]== |
==Si<sub>3</sub>N<sub>4</sub> [PECVD 1]== |
||
Line 24: | Line 25: | ||
===Historical Data=== |
===Historical Data=== |
||
− | Si<sub>3</sub>N<sub>4</sub> [PECVD 1] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=604790654 Si<sub>3</sub>N<sub>4</sub><nowiki> [PECVD 1] Historical Data</nowiki>] |
− | <br /> |
||
==Low Stress Si<sub>3</sub>N<sub>4</sub> [PECVD 2]== |
==Low Stress Si<sub>3</sub>N<sub>4</sub> [PECVD 2]== |
||
Line 33: | Line 33: | ||
===Present Data=== |
===Present Data=== |
||
− | Low Stress Si<sub>3</sub>N<sub>4</sub> [PECVD 1] Present Data |
+ | [https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=1515630363 Low Stress Si<sub>3</sub>N<sub>4</sub><nowiki> [PECVD 1] Present Data</nowiki>] |
===Historical Data=== |
===Historical Data=== |
||
− | Low Stress Si<sub>3</sub>N<sub>4</sub> [PECVD 1] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1fTDNXxpf4tgNYLIEs_jvehG1KvtXqqTRDBI7sHNAVvo/edit#gid=934830479 Low Stress Si<sub>3</sub>N<sub>4</sub><nowiki> [PECVD 1] Historical Data</nowiki>] |
− | <br /> |
||
==Standard Cleaning Procedure [PECVD 1]== |
==Standard Cleaning Procedure [PECVD 1]== |
||
The cleaning procedure is very important in order to have consistent result on this tool and also to keep particulate count low. After each deposition you should clean the tool following instructions carefully. The clean is done in two steps: |
The cleaning procedure is very important in order to have consistent result on this tool and also to keep particulate count low. After each deposition you should clean the tool following instructions carefully. The clean is done in two steps: |
||
Line 48: | Line 47: | ||
=[[PECVD 2 (Advanced Vacuum)]]= |
=[[PECVD 2 (Advanced Vacuum)]]= |
||
+ | |||
+ | === [https://docs.google.com/spreadsheets/d/1iSW1eAAg824y9PYYLG9aiaw53PEJ-f9ofylpVlCDq9Y/edit#gid=272916741 PECVD 2 Plots] === |
||
==SiO<sub>2</sub> [PECVD 2]== |
==SiO<sub>2</sub> [PECVD 2]== |
||
Line 58: | Line 59: | ||
===Historical Data=== |
===Historical Data=== |
||
− | SiO<sub>2</sub> [PECVD 2] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1iSW1eAAg824y9PYYLG9aiaw53PEJ-f9ofylpVlCDq9Y/edit#gid=2024333220 SiO<sub>2</sub><nowiki> [PECVD 2] Historical Data</nowiki>] |
− | <br /> |
||
==Si<sub>3</sub>N<sub>4</sub> [PECVD 2]== |
==Si<sub>3</sub>N<sub>4</sub> [PECVD 2]== |
||
Line 69: | Line 69: | ||
===Historical Data=== |
===Historical Data=== |
||
− | Si<sub>3</sub>N<sub>4</sub> [PECVD 2] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1iSW1eAAg824y9PYYLG9aiaw53PEJ-f9ofylpVlCDq9Y/edit#gid=1153442266 Si<sub>3</sub>N<sub>4</sub><nowiki> [PECVD 2] Historical Data</nowiki>] |
− | <br /> |
||
==Low Stress Si<sub>3</sub>N<sub>4</sub> [PECVD 2]== |
==Low Stress Si<sub>3</sub>N<sub>4</sub> [PECVD 2]== |
||
Line 81: | Line 80: | ||
===Historical Data=== |
===Historical Data=== |
||
− | Low Stress Si<sub>3</sub>N<sub>4</sub> [PECVD 2] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1iSW1eAAg824y9PYYLG9aiaw53PEJ-f9ofylpVlCDq9Y/edit#gid=268003895 Low Stress Si<sub>3</sub>N<sub>4</sub><nowiki> [PECVD 2] Historical Data</nowiki>] |
− | <br /> |
||
==Standard Cleaning Procedure [PECVD 2]== |
==Standard Cleaning Procedure [PECVD 2]== |
||
The cleaning procedure is very important in order to have consistent result on this tool and also to keep particulate count low. After each deposition you should clean the tool following instructions carefully. The clean is done in two steps: |
The cleaning procedure is very important in order to have consistent result on this tool and also to keep particulate count low. After each deposition you should clean the tool following instructions carefully. The clean is done in two steps: |
||
Line 114: | Line 112: | ||
The system currently has Deuterated Silane (SiD<sub>4</sub>) installed - identical to the regular Silicon precursor SiH<sub>4</sub>, except that it significantly lowers optical absorption in the near-infrared due to shifted molecular vibrations/molecular weights. |
The system currently has Deuterated Silane (SiD<sub>4</sub>) installed - identical to the regular Silicon precursor SiH<sub>4</sub>, except that it significantly lowers optical absorption in the near-infrared due to shifted molecular vibrations/molecular weights. |
||
+ | |||
+ | === [https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=417334948https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=417334948 ICP-PECVD Plots] === |
||
==Low Deposition Rate SiO<sub>2</sub> [ICP-PECVD]== |
==Low Deposition Rate SiO<sub>2</sub> [ICP-PECVD]== |
||
Line 124: | Line 124: | ||
===Historical Data=== |
===Historical Data=== |
||
− | Low Deposition Rate SiO<sub>2</sub> [ICP-PECVD] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=1916118198 Low Deposition Rate SiO<sub>2</sub><nowiki> [ICP-PECVD] Historical Data</nowiki>] |
− | <br /> |
||
==High Deposition Rate SiO<sub>2</sub> [ICP-PECVD]== |
==High Deposition Rate SiO<sub>2</sub> [ICP-PECVD]== |
||
Line 136: | Line 135: | ||
===Historical Data=== |
===Historical Data=== |
||
− | High Deposition Rate SiO<sub>2</sub> [ICP-PECVD] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=939753086 High Deposition Rate SiO<sub>2</sub><nowiki> [ICP-PECVD] Historical Data</nowiki>] |
− | |||
− | |||
==Si<sub>3</sub>N<sub>4</sub> [ICP-PECVD]== |
==Si<sub>3</sub>N<sub>4</sub> [ICP-PECVD]== |
||
Line 148: | Line 145: | ||
===Historical Data=== |
===Historical Data=== |
||
− | Si<sub>3</sub>N<sub>4</sub> [ICP-PECVD] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=782128304 Si<sub>3</sub>N<sub>4</sub><nowiki> [ICP-PECVD] Historical Data</nowiki>] |
− | <br /> |
||
==Low Stress Si<sub>3</sub>N<sub>4</sub> [ICP-PECVD]== |
==Low Stress Si<sub>3</sub>N<sub>4</sub> [ICP-PECVD]== |
||
Line 160: | Line 156: | ||
===Historical Data=== |
===Historical Data=== |
||
− | Low Stress Si<sub>3</sub>N<sub>4</sub> [ICP-PECVD] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/1CuDMKFTTzGLL6CP-FEI_9cOnUaIw-432ppDFssB59wY/edit#gid=1024532473 Low Stress Si<sub>3</sub>N<sub>4</sub><nowiki> [ICP-PECVD] Historical Data</nowiki>] |
− | <br /> |
||
==Standard Cleaning Procedure [ICP-PECVD]== |
==Standard Cleaning Procedure [ICP-PECVD]== |
||
You must edit the Post-Dep Clean recipe to correspond to your deposited thickness and material. See the [[ICP-PECVD (Unaxis VLR)#Documentation|Operating Procedure on the Unaxis Tool Page]] for details. |
You must edit the Post-Dep Clean recipe to correspond to your deposited thickness and material. See the [[ICP-PECVD (Unaxis VLR)#Documentation|Operating Procedure on the Unaxis Tool Page]] for details. |
||
Line 169: | Line 164: | ||
===Standard Clean Recipe=== |
===Standard Clean Recipe=== |
||
− | <br /> |
||
=[[Ion Beam Deposition (Veeco NEXUS)]]= |
=[[Ion Beam Deposition (Veeco NEXUS)]]= |
||
+ | |||
+ | === [https://docs.google.com/spreadsheets/d/11A0ac8NU51bmcQ_grQcq9wuPwWnfy1_9MNk2DEo5yyo/edit#gid=2030038046 IBD Plots] === |
||
==SiO<sub>2</sub> [IBD]== |
==SiO<sub>2</sub> [IBD]== |
||
Line 181: | Line 177: | ||
===Historical Data=== |
===Historical Data=== |
||
− | SiO<sub>2</sub> [IBD] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/11A0ac8NU51bmcQ_grQcq9wuPwWnfy1_9MNk2DEo5yyo/edit#gid=700537698 SiO<sub>2</sub><nowiki> [IBD] Historical Data</nowiki>] |
− | <br /> |
||
==Si<sub>3</sub>N<sub>4</sub> [IBD]== |
==Si<sub>3</sub>N<sub>4</sub> [IBD]== |
||
Line 193: | Line 188: | ||
===Historical Data=== |
===Historical Data=== |
||
− | Si<sub>3</sub>N<sub>4</sub> [IBD] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/11A0ac8NU51bmcQ_grQcq9wuPwWnfy1_9MNk2DEo5yyo/edit#gid=2093120876 Si<sub>3</sub>N<sub>4</sub><nowiki> [IBD] Historical Data</nowiki>] |
− | <br /> |
||
==Ta<sub>2</sub>O<sub>5</sub> [IBD]== |
==Ta<sub>2</sub>O<sub>5</sub> [IBD]== |
||
Line 204: | Line 198: | ||
===Historical Data=== |
===Historical Data=== |
||
− | Ta<sub>2</sub>O<sub>5</sub> [IBD] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/11A0ac8NU51bmcQ_grQcq9wuPwWnfy1_9MNk2DEo5yyo/edit#gid=1075234846 Ta<sub>2</sub>O<sub>5</sub><nowiki> [IBD] Historical Data</nowiki>] |
− | <br /> |
||
==Al<sub>2</sub>O<sub>3</sub> [IBD]== |
==Al<sub>2</sub>O<sub>3</sub> [IBD]== |
||
Line 215: | Line 208: | ||
===Historical Data=== |
===Historical Data=== |
||
− | Al<sub>2</sub>O<sub>3</sub> [IBD] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/11A0ac8NU51bmcQ_grQcq9wuPwWnfy1_9MNk2DEo5yyo/edit#gid=1294329492 Al<sub>2</sub>O<sub>3</sub><nowiki> [IBD] Historical Data</nowiki>] |
− | |||
− | <br /> |
||
==TiO<sub>2</sub> [IBD]== |
==TiO<sub>2</sub> [IBD]== |
||
Line 227: | Line 218: | ||
===Historical Data=== |
===Historical Data=== |
||
− | TiO<sub>2</sub> [IBD] Historical Data |
+ | [https://docs.google.com/spreadsheets/d/11A0ac8NU51bmcQ_grQcq9wuPwWnfy1_9MNk2DEo5yyo/edit#gid=1327808550 TiO<sub>2</sub><nowiki> [IBD] Historical Data</nowiki>] |
− | <br /> |
||
==Standard Cleaning Procedure [ICP-PECVD]== |
==Standard Cleaning Procedure [ICP-PECVD]== |
||
You must edit the Post-Dep Clean recipe to correspond to your deposited thickness and material. See the [[ICP-PECVD (Unaxis VLR)#Documentation|Operating Procedure on the Unaxis Tool Page]] for details. |
You must edit the Post-Dep Clean recipe to correspond to your deposited thickness and material. See the [[ICP-PECVD (Unaxis VLR)#Documentation|Operating Procedure on the Unaxis Tool Page]] for details. |
Revision as of 12:45, 30 November 2021
Back to Vacuum Deposition Recipes
PECVD 1 (PlasmaTherm 790)
PECVD 1 Plots
SiO2 [PECVD 1]
Standard Recipe
SiO2 [PECVD 1] Standard Recipe
Present Data
Historical Data
SiO2 [PECVD 1] Historical Data
Si3N4 [PECVD 1]
Standard Recipe
Si3N4 [PECVD 1] Standard Recipe
Present Data
Historical Data
Si3N4 [PECVD 1] Historical Data
Low Stress Si3N4 [PECVD 2]
Standard Recipe
Low Stress Si3N4 [PECVD 1] Standard Recipe
Present Data
Low Stress Si3N4 [PECVD 1] Present Data
Historical Data
Low Stress Si3N4 [PECVD 1] Historical Data
Standard Cleaning Procedure [PECVD 1]
The cleaning procedure is very important in order to have consistent result on this tool and also to keep particulate count low. After each deposition you should clean the tool following instructions carefully. The clean is done in two steps:
- Wet cleaning (start cleaning by using a cleanroom wipe sprayed with DI. Wipe chamber sidewalls with it. Finish cleaning by using the cleanroom wipe sprayed with IPA. )
- Load the recipe for cleaning "CF4/O2 Clean" (edit the recipe and change ONLY time of cleaning). Follow instructions regarding a required time for cleaning.
Standard Cleaning Recipe [CF4/O2 Clean]
Click the above link for a screenshot of the standard cleaning recipe, for which you will enter a custom time. The recipe is set up so that it will pop up a window for the cleaning time upon running the recipe - you do not need to edit the recipe before running it.
PECVD 2 (Advanced Vacuum)
PECVD 2 Plots
SiO2 [PECVD 2]
Standard Recipe
SiO2 [PECVD 2] Standard Recipe
Present Data
Historical Data
SiO2 [PECVD 2] Historical Data
Si3N4 [PECVD 2]
Standard Recipe
Si3N4 [PECVD 2] Standard Recipe
Present Data
Historical Data
Si3N4 [PECVD 2] Historical Data
Low Stress Si3N4 [PECVD 2]
Standard Recipe
Low Stress Si3N4 [PECVD 2] Standard Recipe
Present Data
Low Stress Si3N4 [PECVD 2] Present Data
Historical Data
Low Stress Si3N4 [PECVD 2] Historical Data
Standard Cleaning Procedure [PECVD 2]
The cleaning procedure is very important in order to have consistent result on this tool and also to keep particulate count low. After each deposition you should clean the tool following instructions carefully. The clean is done in two steps:
- (If >29min dep time) Wet cleaning: Start cleaning by using a cleanroom wipe sprayed with DI. Wipe upper chamber sidewalls with it. Finish cleaning by using the cleanroom wipe sprayed with IPA & wiping again.
- Load the recipe for cleaning "STD CF4/O2 Clean" (edit the recipe and change ONLY time of cleaning). Follow instructions regarding required time for cleaning.
Standard Clean Recipe [STD CF4/O2 Clean recipe]
Click the above link for a screenshot of the standard cleaning recipe, for which you will enter a custom time. The recipe is set up so that it will pop up a window for the cleaning time upon running the recipe - you do not need to edit the recipe before running it.
Clean Times (PECVD#2)
Film Deposited | Cleaning Time (Dry) |
---|---|
SiO2 | 1 min. clean for every 1 min. deposition |
Si3N4 | 1 min. clean for every 7 min of deposition |
If > 29min total dep time
(Season + Dep) |
Wet Clean the Upper Lid/Chamber
DI water then Isopropyl Alcohol on chamber wall & portholes |
ICP-PECVD (Unaxis VLR)
2020-02: New recipes have been characterized for low particulate count and repeatability. Only staff-supplied recipes are allowed in the tool. Please follow the new procedures to ensure low particle counts in the chamber.
The system currently has Deuterated Silane (SiD4) installed - identical to the regular Silicon precursor SiH4, except that it significantly lowers optical absorption in the near-infrared due to shifted molecular vibrations/molecular weights.
ICP-PECVD Plots
Low Deposition Rate SiO2 [ICP-PECVD]
Standard Recipe
Low Deposition Rate SiO2 [ICP-PECVD] Standard Recipe
Present Data
Low Deposition Rate SiO2 [ICP-PECVD] Present Data
Historical Data
Low Deposition Rate SiO2 [ICP-PECVD] Historical Data
High Deposition Rate SiO2 [ICP-PECVD]
Standard Recipe
High Deposition Rate SiO2 [ICP-PECVD] Standard Recipe
Present Data
High Deposition Rate SiO2 [ICP-PECVD] Present Data
Historical Data
High Deposition Rate SiO2 [ICP-PECVD] Historical Data
Si3N4 [ICP-PECVD]
Standard Recipe
Si3N4 [ICP-PECVD] Standard Recipe
Present Data
Si3N4 [ICP-PECVD] Present Data
Historical Data
Si3N4 [ICP-PECVD] Historical Data
Low Stress Si3N4 [ICP-PECVD]
Standard Recipe
Low Stress Si3N4 [ICP-PECVD] Standard Recipe
Present Data
Low Stress Si3N4 [ICP-PECVD] Present Data
Historical Data
Low Stress Si3N4 [ICP-PECVD] Historical Data
Standard Cleaning Procedure [ICP-PECVD]
You must edit the Post-Dep Clean recipe to correspond to your deposited thickness and material. See the Operating Procedure on the Unaxis Tool Page for details.
- SiNx etches at 20nm/min
- SiO2 etches at 40nm/min
Standard Clean Recipe
Ion Beam Deposition (Veeco NEXUS)
IBD Plots
SiO2 [IBD]
Standard Recipe
SiO2 [IBD] Standard Recipe
Present Data
Historical Data
Si3N4 [IBD]
Standard Recipe
Si3N4 [IBD] Standard Recipe
Present Data
Historical Data
Ta2O5 [IBD]
Standard Recipe
Ta2O5 [IBD] Standard Recipe
Present Data
Historical Data
Al2O3 [IBD]
Standard Recipe
Al2O3 [IBD] Standard Recipe
Present Data
Historical Data
TiO2 [IBD]
Standard Recipe
TiO2 [IBD] Standard Recipe
Present Data
Historical Data
Standard Cleaning Procedure [ICP-PECVD]
You must edit the Post-Dep Clean recipe to correspond to your deposited thickness and material. See the Operating Procedure on the Unaxis Tool Page for details.
- SiNx etches at 20nm/min
- SiO2 etches at 40nm/min