Difference between revisions of "Nanofab Job Postings"
Jump to navigation
Jump to search
(added direct link to job posting) |
(→Process/Wafer Fab Engineer Level 3 (Staff position): not reviewing apps) |
||
(7 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
⚫ | |||
+ | |||
==Current Openings== |
==Current Openings== |
||
''The following are positions we are currently hiring for:'' |
''The following are positions we are currently hiring for:'' |
||
+ | ===Process/Wafer Fab Engineer Level 2 (Staff Position)=== |
||
− | + | Apply at this link: [https://careerspub.universityofcalifornia.edu/psp/ucsb/EMPLOYEE/HRMS/c/HRS_HRAM.HRS_APP_SCHJOB.GBL?Page=HRS_APP_JBPST&Action=U&FOCUS=Applicant&SiteId=31&JobOpeningId=65571&PostingSeq=1 jobs.ucsb.edu (#65571) - R&D Engineer Level 2] |
|
+ | *Under the supervision of a R&D3 Engineer, develops processes and establishes process control on a variety of nanofabrication research tools within the facility, including thin film deposition, inductively coupled plasma etching, and projection lithography. |
||
⚫ | |||
+ | *Works to establish and document standard procedures as well as new process modules for a variety of nanofabrication processes through direct hands-on processing and results documentation. |
||
+ | *Assigned work will support engineering staff, facility users, and facility projects. |
||
+ | ===Process/Wafer Fab Engineer Level 3 (Staff position)=== |
||
+ | '''''We are no longer reviewing applications for this position''''' |
||
+ | Apply at this link: [https://careerspub.universityofcalifornia.edu/psp/ucsb/EMPLOYEE/HRMS/c/HRS_HRAM.HRS_APP_SCHJOB.GBL?Page=HRS_APP_JBPST&Action=U&FOCUS=Applicant&SiteId=31&JobOpeningId=60935&PostingSeq=1 jobs.ucsb.edu (# 60935): Research & Development Engineer level 3] |
||
+ | *Process Development for Fab processes: Developing and executing fabrication processes for external customers and internal lab needs. |
||
⚫ | |||
+ | *Process Development for Lab equipment: Developing new recipes and designing/running DOE's for new/existing lab equipment. |
||
+ | *User Support: Giving fabrication advice to internal/external users. |
||
+ | *Process Control: Observing + Troubleshooting process drift/deviations, improving process repeatability. |
||
+ | |||
+ | ==Filled Positions== |
||
+ | |||
+ | ===1) Intern - Processing Technician - Thin-Film & Etch Characterizations=== |
||
+ | |||
+ | *This position is for current UCSB Undergraduate students. Ideally in a technical field, optionally having taken one of the cleanroom course (neither are required). |
||
+ | |||
⚫ | |||
+ | *Running thin-film calibrations on various high-use deposition tools, as listed on the [[Process Group - Process Control Data#Deposition .28Process Control Data.29|Deposition: Process Control data]]. These are user-accessible (public) charts and data that users consult to ensure the tools are operating as expected, and/or for troubleshooting problems in the fabrication process. |
||
− | <br /> |
||
− | == |
+ | ==View all Nanofab Job Openings== |
To search for available NanoFab job positions, follow these instructions: |
To search for available NanoFab job positions, follow these instructions: |
||
Latest revision as of 16:16, 12 March 2024
You can see our Organization Chart here: https://www.nanotech.ucsb.edu/staff
Current Openings
The following are positions we are currently hiring for:
Process/Wafer Fab Engineer Level 2 (Staff Position)
Apply at this link: jobs.ucsb.edu (#65571) - R&D Engineer Level 2
- Under the supervision of a R&D3 Engineer, develops processes and establishes process control on a variety of nanofabrication research tools within the facility, including thin film deposition, inductively coupled plasma etching, and projection lithography.
- Works to establish and document standard procedures as well as new process modules for a variety of nanofabrication processes through direct hands-on processing and results documentation.
- Assigned work will support engineering staff, facility users, and facility projects.
Process/Wafer Fab Engineer Level 3 (Staff position)
We are no longer reviewing applications for this position
Apply at this link: jobs.ucsb.edu (# 60935): Research & Development Engineer level 3
- Process Development for Fab processes: Developing and executing fabrication processes for external customers and internal lab needs.
- Process Development for Lab equipment: Developing new recipes and designing/running DOE's for new/existing lab equipment.
- User Support: Giving fabrication advice to internal/external users.
- Process Control: Observing + Troubleshooting process drift/deviations, improving process repeatability.
Filled Positions
1) Intern - Processing Technician - Thin-Film & Etch Characterizations
- This position is for current UCSB Undergraduate students. Ideally in a technical field, optionally having taken one of the cleanroom course (neither are required).
- A position in the "Process Group", led by Demis D. John.
- Running thin-film calibrations on various high-use deposition tools, as listed on the Deposition: Process Control data. These are user-accessible (public) charts and data that users consult to ensure the tools are operating as expected, and/or for troubleshooting problems in the fabrication process.
View all Nanofab Job Openings
To search for available NanoFab job positions, follow these instructions:
- Follow the appropriate link:
- Staff Jobs for "External Applicants" - not a current UCSB employee
- Staff Jobs for "Internal Applicants" - for current UCSB employees
- In the "keywords" search field, search for "NanoFab".
- All available NanoFab job postings should be listed.
(The same can be done by going to https://www.jobs.ucsb.edu/ > scroll to Browse Jobs > Choose Internal or External applicant.)