Difference between revisions of "Microscopes"
(added LEXT) (Tag: Visual edit) |
(added some model numbers and links to the relevant pages/manuals) (Tag: Visual edit) |
||
Line 8: | Line 8: | ||
}} |
}} |
||
==Nikon== |
==Nikon== |
||
− | The lab currently has 3 Nikon Microscopes (Microscopes #2, #3 & #4). These are located in bays 6 and 7. |
+ | The lab currently has 3 Nikon Microscopes (Microscopes #2, #3 & #4). These are located in bays 6 and 7. |
+ | |||
+ | The scopes are connected to computers via Jenoptik ProgRes software which allows users to digitally capture images through the microscope and make calibrated measurements. |
||
+ | * Microscope #2: (Bay 7) |
||
+ | * [https://www.nanotech.ucsb.edu/wiki/images/8/80/Nikon-Microscope-Manual.pdf Microscope #3: Eclipse Nikon L200D (Bay 6)] |
||
+ | * Microscope #4: (Bay 6) |
||
==Olympus== |
==Olympus== |
||
− | The lab currently has |
+ | The lab currently has two Olympus microscopes: |
+ | * [https://www.nanotech.ucsb.edu/wiki/images/2/28/Nikon-Microscope-OptiPhot-Manual.pdf Microscope #1: Olympus Optiphot-2 (Bay 3)] |
||
+ | * [[Fluorescence Microscope (Olympus MX51)|Fluorescence Microscope: Olympus MX51 (Bay 6)]] |
||
− | == Olympus LEXT Confocal Microscope == |
+ | == [[Laser Scanning Confocal M-scope (Olympus LEXT)|Olympus LEXT Confocal Microscope]] == |
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training. |
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training. |
||
The LEXT has a motorized stage, image stitching capabilities and some image measurement capabilities, in addition to the primary topographical measurement capabilities afforded by the laser-scanning confocal microscopy function. |
The LEXT has a motorized stage, image stitching capabilities and some image measurement capabilities, in addition to the primary topographical measurement capabilities afforded by the laser-scanning confocal microscopy function. |
Revision as of 22:30, 31 August 2018
|
Nikon
The lab currently has 3 Nikon Microscopes (Microscopes #2, #3 & #4). These are located in bays 6 and 7.
The scopes are connected to computers via Jenoptik ProgRes software which allows users to digitally capture images through the microscope and make calibrated measurements.
- Microscope #2: (Bay 7)
- Microscope #3: Eclipse Nikon L200D (Bay 6)
- Microscope #4: (Bay 6)
Olympus
The lab currently has two Olympus microscopes:
Olympus LEXT Confocal Microscope
YOU ARE REQUIRED TO GET TRAINED on this tool before you are allowed to use it! Please contact the Tool Owner to get training.
The LEXT has a motorized stage, image stitching capabilities and some image measurement capabilities, in addition to the primary topographical measurement capabilities afforded by the laser-scanning confocal microscopy function.
See the main tool page for more info: Laser Scanning Confocal M-scope (Olympus LEXT)
Documentation
- Microscope Training - General procedures and info for using our microscopes