Difference between revisions of "Maskless Aligner (Heidelberg MLA150)"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(→‎Documentation: added redlinks for documentation)
(added tool id, HIMT URL, updated specs)
Line 1: Line 1:
{{WIP}}
 
 
{{tool|{{PAGENAME}}
 
{{tool|{{PAGENAME}}
 
|picture=MLA150_Heidelberg_Bay_6_Photo.jpg
 
|picture=MLA150_Heidelberg_Bay_6_Photo.jpg
Line 5: Line 4:
 
|super = Biljana Stamenic
 
|super = Biljana Stamenic
 
|location = Bay 6
 
|location = Bay 6
|description = Maskless I-Line Photolithography
+
|description = Direct-Write (Maskless) I-Line Photolithography
|manufacturer = Heidelberg Instruments
+
|manufacturer = [https://heidelberg-instruments.com Heidelberg Instruments]
 
|model = MLA150
 
|model = MLA150
 +
|toolid=32
 
|materials = I-Line Photoresists
 
|materials = I-Line Photoresists
 
}}  
 
}}  
 
==About==
 
==About==
The MLA150 allows for arbitrary direct patterning of I-Line photoresists, directly from an uploaded CAD drawing/file (GDS, DXF, CIF etc.). The system uses a  [https://en.wikipedia.org/wiki/Digital_micromirror_device digital micromirror device] ("DMD", an array of MEMS mirrors) for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required.
+
The MLA150 allows for arbitrary direct-write patterning of I-Line photoresists from an uploaded CAD drawing/file (GDS, DXF, CIF etc.). The system uses a  [https://en.wikipedia.org/wiki/Digital_micromirror_device digital micromirror device] ("DMD", an array of MEMS mirrors) for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required.
  
The system has a continuous, automatic autofocus, using either a pneumatic or optical detection. This enables lithography on non-planar or curved substrates. We also have the high-aspect ratio (variable/long focal length) option installed for very thick (~70µm) photoresists.
+
Depending on the exposure options and write area, the MLA is able to expose a 100mm wafer in about 30min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm.  
  
Depending on the exposure options and write area, the MLA is able to expose a 100mm wafer in about 30min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm. Arbitrary drawings can be exposed onto any feature located on the microscope.
+
The system has a continuous, automatic autofocus, using pneumatic and optical detection. This potentially enables lithography on non-planar or curved substrates.
  
Greyscale lithography is capable of producing repeatable slanted or tapered structures in photoresist or photo-active dielectrics like SU-8.
+
The software allows for custom drawings and aligment marks to be exposed onto any feature located on the microscope.
 +
 
 +
Greyscale lithography allows for photoresist profiles with repeatable slanted or tapered structures.
 +
 
 +
The high-aspect ratio (variable/long focal length) option enables vertical sidewalls on very thick (~100µm) photoresists.
  
 
==Detailed Specifications==
 
==Detailed Specifications==
  
*Wafer size:  
+
*Substrate size: 9-inch square or 200mm round down to 5-mm pieces
*Wafer / substrate thickness: Max. 9mm.
+
*Wafer / substrate thickness: Max. 9mm / Min. 0.1mm
**Thicker is possible, contact supervisor.  
 
 
*Exposure optics:
 
*Exposure optics:
 
**[https://en.wikipedia.org/wiki/Digital_micromirror_device Digital micromirror device (DMD)]  
 
**[https://en.wikipedia.org/wiki/Digital_micromirror_device Digital micromirror device (DMD)]  
Line 29: Line 32:
 
**Laser #2: 405nm
 
**Laser #2: 405nm
 
* Alignment Accuracy: ≤ 200nm
 
* Alignment Accuracy: ≤ 200nm
 +
* Linewidth variation: ≤100nm
  
 
*Additional manufacturer options:
 
*Additional manufacturer options:
Line 38: Line 42:
  
 
=== Operating Procedures ===
 
=== Operating Procedures ===
*[[Media:MLA150 - Standard Operating Procedure.pdf|MLA150 - Standard Operating Procedure]]
+
*[[Special:FilePath/MLA150 - Standard Operating Procedure.pdf|MLA150 - Standard Operating Procedure]]
  
 
=== Video Trainings ===
 
=== Video Trainings ===
* [[Part 1: Overview and basic usage]]
+
'''Important:''' You must be <u>authorized by a supervisor</u> to use the tool!  The video below is provided for reference only, and does not substitute training by NanoFab  staff.
* [[Part 2: Focus Exposure Matrix (FEM)/Series]]
+
* [[Part 1: Overview and basic usage|Heidelberg MLA150 Training]]
* [[Part 3: Local "Field" Alignment]]
 
  
 
== Design Tools/Info ==
 
== Design Tools/Info ==

Revision as of 09:16, 4 November 2020

Maskless Aligner (Heidelberg MLA150)
MLA150 Heidelberg Bay 6 Photo.jpg
Tool Type Lithography
Location Bay 6
Supervisor Biljana Stamenic
Supervisor Phone (805) 893-4002
Supervisor E-Mail biljana@ece.ucsb.edu
Description Direct-Write (Maskless) I-Line Photolithography
Manufacturer Heidelberg Instruments
Model MLA150
Materials I-Line Photoresists
Sign up for this tool


About

The MLA150 allows for arbitrary direct-write patterning of I-Line photoresists from an uploaded CAD drawing/file (GDS, DXF, CIF etc.). The system uses a digital micromirror device ("DMD", an array of MEMS mirrors) for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required.

Depending on the exposure options and write area, the MLA is able to expose a 100mm wafer in about 30min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm.

The system has a continuous, automatic autofocus, using pneumatic and optical detection. This potentially enables lithography on non-planar or curved substrates.

The software allows for custom drawings and aligment marks to be exposed onto any feature located on the microscope.

Greyscale lithography allows for photoresist profiles with repeatable slanted or tapered structures.

The high-aspect ratio (variable/long focal length) option enables vertical sidewalls on very thick (~100µm) photoresists.

Detailed Specifications

  • Substrate size: 9-inch square or 200mm round down to 5-mm pieces
  • Wafer / substrate thickness: Max. 9mm / Min. 0.1mm
  • Exposure optics:
  • Alignment Accuracy: ≤ 200nm
  • Linewidth variation: ≤100nm
  • Additional manufacturer options:
    • High-resolution option (Write Mode 1)
    • Extended Focus Range
    • Variable Focal Depth
    • Optical (laser) Autofocus in addition to Pneumatic Autofocus

Documentation

Operating Procedures

Video Trainings

Important: You must be authorized by a supervisor to use the tool!  The video below is provided for reference only, and does not substitute training by NanoFab  staff.

Design Tools/Info

Recipes