Difference between revisions of "Maskless Aligner (Heidelberg MLA150)"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(Added photo)
(→‎About: minor updates)
Line 11: Line 11:
 
}}  
 
}}  
 
==About==
 
==About==
The MLA150 allows for arbitrary direct patterning of I-Line photoresists, directly from a CAD drawing/file, with alignment to arbitrary features on the sample. The system uses a  [https://en.wikipedia.org/wiki/Digital_micromirror_device digital micromirror device] ("DMD", an array of MEMS mirrors) for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required.
+
The MLA150 allows for arbitrary direct patterning of I-Line photoresists, directly from an uploaded CAD drawing/file (GDS, DXF, CIF etc.). The system uses a  [https://en.wikipedia.org/wiki/Digital_micromirror_device digital micromirror device] ("DMD", an array of MEMS mirrors) for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required.
  
 
The system has a continuous, automatic autofocus, using either a pneumatic or optical detection. This enables lithography on non-planar or curved substrates. We also have the high-aspect ratio (variable/long focal length) option installed for very thick (~70µm) photoresists.
 
The system has a continuous, automatic autofocus, using either a pneumatic or optical detection. This enables lithography on non-planar or curved substrates. We also have the high-aspect ratio (variable/long focal length) option installed for very thick (~70µm) photoresists.
  
Depending on the exposure options and write area, MLA is able to expose a 100mm wafer in about 30min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm.
+
Depending on the exposure options and write area, the MLA is able to expose a 100mm wafer in about 30min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm. Arbitrary drawings can be exposed onto any feature located on the microscope.
  
 
Lastly, the greyscale lithography is possible, producing repeatable, slanted or tapered structures in photoresist or photo-active dielectrics like SU-8.
 
Lastly, the greyscale lithography is possible, producing repeatable, slanted or tapered structures in photoresist or photo-active dielectrics like SU-8.
Line 24: Line 24:
 
*Wafer / substrate thickness:  
 
*Wafer / substrate thickness:  
 
*Exposure optics:
 
*Exposure optics:
 +
**[https://en.wikipedia.org/wiki/Digital_micromirror_device Digital micromirror device (DMD)]
 
**Laser #1: 375nm
 
**Laser #1: 375nm
 
**Laser #2: 405nm
 
**Laser #2: 405nm
 
* Focus modes:
 
* Focus modes:
* Alignment:
+
** Extended Focus Range
** Modes?
+
** Variable Focal Depth
** Accuracy:  
+
* Alignment Accuracy: ≤ 200nm
** Repetability
 
  
 
*Additional manufacturer options:
 
*Additional manufacturer options:
**Focus option?
+
**High-resolution option
**Dual lasers?
 
**High-resolution option?
 
 
 
* Uniformity:
 
* Write speeds:
 
 
 
 
 
 
==Documentation==
 
==Documentation==
 
*[[MLA150 - Standard Operating Procedure]]
 
*[[MLA150 - Standard Operating Procedure]]

Revision as of 22:49, 2 October 2020

UnderConstruction.jpg

Work In Progress

This article is still under construction. It may contain factual errors. Content is subject to change.


Maskless Aligner (Heidelberg MLA150)
MLA150 Heidelberg Bay 6 Photo.jpg
Tool Type Lithography
Location Bay 6
Supervisor Biljana Stamenic
Supervisor Phone (805) 893-4002
Supervisor E-Mail biljana@ece.ucsb.edu
Description Maskless I-Line Photolithography
Manufacturer Heidelberg Instruments
Model MLA150
Materials I-Line Photoresists


About

The MLA150 allows for arbitrary direct patterning of I-Line photoresists, directly from an uploaded CAD drawing/file (GDS, DXF, CIF etc.). The system uses a digital micromirror device ("DMD", an array of MEMS mirrors) for patterning the exposure light-field, to programmatically expose digitized patterns directly onto the sample - no glass photomasks/reticles are required.

The system has a continuous, automatic autofocus, using either a pneumatic or optical detection. This enables lithography on non-planar or curved substrates. We also have the high-aspect ratio (variable/long focal length) option installed for very thick (~70µm) photoresists.

Depending on the exposure options and write area, the MLA is able to expose a 100mm wafer in about 30min, and achieves minimum features sizes around 0.5µm, with overlay/alignment accuracy better than 200nm. Arbitrary drawings can be exposed onto any feature located on the microscope.

Lastly, the greyscale lithography is possible, producing repeatable, slanted or tapered structures in photoresist or photo-active dielectrics like SU-8.

Detailed Specifications

  • Wafer size:
  • Wafer / substrate thickness:
  • Exposure optics:
  • Focus modes:
    • Extended Focus Range
    • Variable Focal Depth
  • Alignment Accuracy: ≤ 200nm
  • Additional manufacturer options:
    • High-resolution option

Documentation

Design Tools/Info

Recipes