https://wiki.nanofab.ucsb.edu/w/index.php?title=MLA150_-_Large_Image_GDS_Generation&feed=atom&action=history
MLA150 - Large Image GDS Generation - Revision history
2024-03-29T15:51:31Z
Revision history for this page on the wiki
MediaWiki 1.35.13
https://wiki.nanofab.ucsb.edu/w/index.php?title=MLA150_-_Large_Image_GDS_Generation&diff=160150&oldid=prev
John d: updated formatting/numbered list
2022-07-29T23:45:51Z
<p>updated formatting/numbered list</p>
<a href="https://wiki.nanofab.ucsb.edu/w/index.php?title=MLA150_-_Large_Image_GDS_Generation&diff=160150&oldid=158762">Show changes</a>
John d
https://wiki.nanofab.ucsb.edu/w/index.php?title=MLA150_-_Large_Image_GDS_Generation&diff=158762&oldid=prev
John d at 19:27, 5 February 2021
2021-02-05T19:27:24Z
<p></p>
<table class="diff diff-contentalign-left diff-editfont-monospace" data-mw="interface">
<col class="diff-marker" />
<col class="diff-content" />
<col class="diff-marker" />
<col class="diff-content" />
<tr class="diff-title" lang="en">
<td colspan="2" style="background-color: #fff; color: #202122; text-align: center;">← Older revision</td>
<td colspan="2" style="background-color: #fff; color: #202122; text-align: center;">Revision as of 19:27, 5 February 2021</td>
</tr><tr>
<td colspan="2" class="diff-lineno">Line 4:</td>
<td colspan="2" class="diff-lineno">Line 4:</td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>==== Procedure ====</div></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>==== Procedure ====</div></td>
</tr>
<tr>
<td colspan="2" class="diff-empty"> </td>
<td class="diff-marker">+</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker">−</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>'''[https://www.gimp.org/ GIMP]:''' (can also do in another image editor, such as Paint.exe)</div></td>
<td class="diff-marker">+</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins class="diffchange diffchange-inline">'''1)''' In </ins>'''[https://www.gimp.org/ GIMP]:''' (can also do in another image editor, such as Paint.exe)</div></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>open the Image (JPG, PNG, BMP etc.), </div></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>open the Image (JPG, PNG, BMP etc.), </div></td>
</tr>
<tr>
<td colspan="2" class="diff-lineno">Line 16:</td>
<td colspan="2" class="diff-lineno">Line 17:</td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Save as any JPG, PNG, BMP format</div></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Save as any JPG, PNG, BMP format</div></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker">−</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>'''[https://inkscape.org/ Inkscape]:'''</div></td>
<td class="diff-marker">+</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins class="diffchange diffchange-inline">'''2)''' In </ins>'''[https://inkscape.org/ Inkscape]:'''</div></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Open the Image file, default options</div></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Open the Image file, default options</div></td>
</tr>
<tr>
<td colspan="2" class="diff-lineno">Line 46:</td>
<td colspan="2" class="diff-lineno">Line 47:</td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>> UNCHECK "Robo" and "LWPOLYLINE" - important, or the lines won’t be connected as a single object.</div></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>> UNCHECK "Robo" and "LWPOLYLINE" - important, or the lines won’t be connected as a single object.</div></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker">−</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>'''[https://www.klayout.de/ Klayout]:'''</div></td>
<td class="diff-marker">+</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins class="diffchange diffchange-inline">'''3)''' In </ins>'''[https://www.klayout.de/ Klayout]:'''</div></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Open the DXF in Klayout</div></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Open the DXF in Klayout</div></td>
</tr>
<tr>
<td colspan="2" class="diff-lineno">Line 60:</td>
<td colspan="2" class="diff-lineno">Line 61:</td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Take note of which Cell & Layer should be printed</div></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Take note of which Cell & Layer should be printed</div></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker">−</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>'''MLA:'''</div></td>
<td class="diff-marker">+</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins class="diffchange diffchange-inline">'''4)''' On the </ins>'''MLA:'''</div></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>[Convert Design] and Import the GDS, </div></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>[Convert Design] and Import the GDS, </div></td>
</tr>
</table>
John d
https://wiki.nanofab.ucsb.edu/w/index.php?title=MLA150_-_Large_Image_GDS_Generation&diff=158667&oldid=prev
John d: pasted method
2021-01-08T05:45:51Z
<p>pasted method</p>
<table class="diff diff-contentalign-left diff-editfont-monospace" data-mw="interface">
<col class="diff-marker" />
<col class="diff-content" />
<col class="diff-marker" />
<col class="diff-content" />
<tr class="diff-title" lang="en">
<td colspan="2" style="background-color: #fff; color: #202122; text-align: center;">← Older revision</td>
<td colspan="2" style="background-color: #fff; color: #202122; text-align: center;">Revision as of 05:45, 8 January 2021</td>
</tr><tr>
<td colspan="2" class="diff-lineno">Line 1:</td>
<td colspan="2" class="diff-lineno">Line 1:</td>
</tr>
<tr>
<td class="diff-marker">−</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>Instructions on how to take a regular rasterized image (eg. JPG, BMP, PNG etc.) and convert it into a vectorized format compatible with the MLA150. This produces a much smaller file than a raw BMP image, because large-area polygons are created, as opposed to defining each pixel across a 150mm wafer (which hits the RAM limit on the computer).<del class="diffchange diffchange-inline"> </del></div></td>
<td class="diff-marker">+</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div>Instructions on how to take a regular rasterized image (eg. JPG, BMP, PNG etc.) and convert it into a vectorized format compatible with the MLA150. This produces a much smaller file than a raw BMP image, because large-area polygons are created, as opposed to<ins class="diffchange diffchange-inline"> the BMP file</ins> defining each<ins class="diffchange diffchange-inline"> ~4µm</ins> pixel across a 150mm wafer (which hits the RAM limit on the computer).</div></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker">−</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>In this example, we convert the image into <del class="diffchange diffchange-inline">simple</del> 1-bit black-and-white image using the free software [https://www.gimp.org GIMP], and then convert to a Vector format using the free software [https://inkscape.org InkScape]. Then we correct the scale and convert to GDS using the free software [https://www.klayout.de KLayout].</div></td>
<td class="diff-marker">+</td>
<td style="color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div>In this example, we convert the image into <ins class="diffchange diffchange-inline">a</ins> 1-bit black-and-white image using the free software [https://www.gimp.org GIMP], and then convert to a Vector format using the free software [https://inkscape.org InkScape]. Then we correct the scale and convert to GDS using the free software [https://www.klayout.de KLayout]<ins class="diffchange diffchange-inline">., which is then ready for exposure on the MLA</ins>.</div></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td>
</tr>
<tr>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>==== Procedure ====</div></td>
<td class="diff-marker"> </td>
<td style="background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>==== Procedure ====</div></td>
</tr>
</table>
John d
https://wiki.nanofab.ucsb.edu/w/index.php?title=MLA150_-_Large_Image_GDS_Generation&diff=158666&oldid=prev
John d: pasted method
2021-01-08T05:43:49Z
<p>pasted method</p>
<p><b>New page</b></p><div>Instructions on how to take a regular rasterized image (eg. JPG, BMP, PNG etc.) and convert it into a vectorized format compatible with the MLA150. This produces a much smaller file than a raw BMP image, because large-area polygons are created, as opposed to defining each pixel across a 150mm wafer (which hits the RAM limit on the computer). <br />
<br />
In this example, we convert the image into simple 1-bit black-and-white image using the free software [https://www.gimp.org GIMP], and then convert to a Vector format using the free software [https://inkscape.org InkScape]. Then we correct the scale and convert to GDS using the free software [https://www.klayout.de KLayout].<br />
<br />
==== Procedure ====<br />
'''[https://www.gimp.org/ GIMP]:''' (can also do in another image editor, such as Paint.exe)<br />
<br />
open the Image (JPG, PNG, BMP etc.), <br />
<br />
Image > Mode > Indexed > 1-bit<br />
<br />
Optional: Dither to handle grey values, haven't tried this.<br />
<br />
Can edit by painting etc.<br />
<br />
Save as any JPG, PNG, BMP format<br />
<br />
'''[https://inkscape.org/ Inkscape]:'''<br />
<br />
Open the Image file, default options<br />
<br />
Click on the Image with the Arrow tool, to select it.<br />
<br />
Path > Trace Bitmap (options affect curves/resolution)<br />
<br />
- Use the “Update” button to show a Preview of the Path that will be created.<br />
<br />
- Options: Trace BitMap > Single-Scan > AutoTrace (dropdown menu). <br />
<br />
- [OK] to create the Path, then Close the “Trace Bitmap” window.<br />
<br />
- Creates a new Path object that outlines the image<br />
<br />
Use the Arrow select tool to select the Image<br />
<br />
- bottom bar shows what object is selected<br />
<br />
- Option/Alt-Click to select obscured objects<br />
<br />
- Make sure PATH is Not selected<br />
<br />
Delete the Image. File should have only the Path object in it.<br />
<br />
File > Save a Copy… > DXF (Autocad R14) <br />
<br />
> UNCHECK "Robo" and "LWPOLYLINE" - important, or the lines won’t be connected as a single object.<br />
<br />
'''[https://www.klayout.de/ Klayout]:'''<br />
<br />
Open the DXF in Klayout<br />
<br />
Use Cell Instance to scale up to desired size:<br />
* Create a new Cell<br />
* Instance the original Cell into that.<br />
* Edit Cell Instance properties to adjust scaling<br />
Use Move tool to Center image at 0,0<br />
<br />
Save as GDS<br />
* Change file extension to ''lower case'' “gds” important, or MLA ''convert'' software won’t see the file.<br />
Take note of which Cell & Layer should be printed<br />
<br />
'''MLA:'''<br />
<br />
[Convert Design] and Import the GDS, <br />
<br />
Choose correct Cell from dropdown<br />
<br />
Set correct Layer: set 1st line to correct layer & uncheck the others<br />
<br />
[Viewer] to make sure scale is correct<br />
<br />
Ready to expose the pattern as normal.</div>