Difference between revisions of "Lithography Recipes"
Jump to navigation
Jump to search
m (→Automated Coat/Develop System Recipes (S-Cubed Flexi): link to tool page) |
(added ARC row with links to DSK & DUV42P) |
||
Line 25: | Line 25: | ||
|- bgcolor="#D0E7FF" | |- bgcolor="#D0E7FF" | ||
! colspan="9" height="45" |<div style="font-size: 150%;">Photolithography Recipes</div> | ! colspan="9" height="45" |<div style="font-size: 150%;">Photolithography Recipes</div> | ||
+ | |||
|- bgcolor="#D0E7FF" | |- bgcolor="#D0E7FF" | ||
|<!-- INTENTIONALLY LEFT BLANK --><br> | |<!-- INTENTIONALLY LEFT BLANK --><br> | ||
! colspan="2" bgcolor="#D0E7FF" align="center" |'''[[Contact Alignment Recipes|Contact Aligners]]''' | ! colspan="2" bgcolor="#D0E7FF" align="center" |'''[[Contact Alignment Recipes|Contact Aligners]]''' | ||
! colspan="3" bgcolor="#D0E7FF" align="center" |'''[[Stepper Recipes|Steppers]]''' | ! colspan="3" bgcolor="#D0E7FF" align="center" |'''[[Stepper Recipes|Steppers]]''' | ||
+ | |||
|- | |- | ||
! width="150" bgcolor="#D0E7FF" align="center" |'''Positive Resists''' | ! width="150" bgcolor="#D0E7FF" align="center" |'''Positive Resists''' | ||
{{LithRecipe Table}} | {{LithRecipe Table}} | ||
− | + | ||
|- | |- | ||
Line 42: | Line 44: | ||
| bgcolor="EEFFFF" |A | | bgcolor="EEFFFF" |A | ||
| bgcolor="EEFFFF" | | | bgcolor="EEFFFF" | | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |AZ4210 | | bgcolor="#D0E7FF" align="center" |AZ4210 | ||
Line 49: | Line 52: | ||
|A | |A | ||
|<br> | |<br> | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |AZ4330RS | | bgcolor="#D0E7FF" align="center" |AZ4330RS | ||
Line 56: | Line 60: | ||
| bgcolor="EEFFFF" |A | | bgcolor="EEFFFF" |A | ||
| bgcolor="EEFFFF" | | | bgcolor="EEFFFF" | | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |OCG 825-35CS | | bgcolor="#D0E7FF" align="center" |OCG 825-35CS | ||
Line 63: | Line 68: | ||
|A | |A | ||
|<br> | |<br> | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |SPR 950-0.8 | | bgcolor="#D0E7FF" align="center" |SPR 950-0.8 | ||
Line 70: | Line 76: | ||
| bgcolor="EEFFFF" |A | | bgcolor="EEFFFF" |A | ||
| bgcolor="EEFFFF" | | | bgcolor="EEFFFF" | | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-0.9 | | bgcolor="#D0E7FF" align="center" |SPR 955 CM-0.9 | ||
Line 77: | Line 84: | ||
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}} | |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}} | ||
|<br> | |<br> | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |SPR 955 CM-1.8 | | bgcolor="#D0E7FF" align="center" |SPR 955 CM-1.8 | ||
Line 84: | Line 92: | ||
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}} | | bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}} | ||
| bgcolor="EEFFFF" | | | bgcolor="EEFFFF" | | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |SPR 220-3.0 | | bgcolor="#D0E7FF" align="center" |SPR 220-3.0 | ||
Line 91: | Line 100: | ||
|{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}} | |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}} | ||
|<br> | |<br> | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |SPR 220-7.0 | | bgcolor="#D0E7FF" align="center" |SPR 220-7.0 | ||
Line 98: | Line 108: | ||
| bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}} | | bgcolor="EEFFFF" |{{rl|Stepper Recipes|Positive Resist (AutoStep 200)}} | ||
| bgcolor="EEFFFF" | | | bgcolor="EEFFFF" | | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |THMR-IP3600 HP D | | bgcolor="#D0E7FF" align="center" |THMR-IP3600 HP D | ||
Line 105: | Line 116: | ||
|A | |A | ||
|<br> | |<br> | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |UV6-0.8 | | bgcolor="#D0E7FF" align="center" |UV6-0.8 | ||
Line 112: | Line 124: | ||
| bgcolor="EEFFFF" | | | bgcolor="EEFFFF" | | ||
| bgcolor="EEFFFF" |[https://www.nanotech.ucsb.edu/wiki/index.php/Stepper_Recipes#Positive_Resist_.28ASML_DUV.29 R] | | bgcolor="EEFFFF" |[https://www.nanotech.ucsb.edu/wiki/index.php/Stepper_Recipes#Positive_Resist_.28ASML_DUV.29 R] | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |UV210-0.3 | | bgcolor="#D0E7FF" align="center" |UV210-0.3 | ||
Line 119: | Line 132: | ||
| | | | ||
|[https://www.nanotech.ucsb.edu/wiki/index.php/Stepper_Recipes#Positive_Resist_.28ASML_DUV.29 R] | |[https://www.nanotech.ucsb.edu/wiki/index.php/Stepper_Recipes#Positive_Resist_.28ASML_DUV.29 R] | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |UV26-2.5 | | bgcolor="#D0E7FF" align="center" |UV26-2.5 | ||
Line 126: | Line 140: | ||
| bgcolor="EEFFFF" | | | bgcolor="EEFFFF" | | ||
| bgcolor="EEFFFF" |A | | bgcolor="EEFFFF" |A | ||
+ | |||
+ | |||
|- | |- | ||
! bgcolor="#D0E7FF" align="center" |'''Negative Resists''' | ! bgcolor="#D0E7FF" align="center" |'''Negative Resists''' | ||
{{LithRecipe Table}} | {{LithRecipe Table}} | ||
− | |||
|- bgcolor="EEFFFF" | |- bgcolor="EEFFFF" | ||
Line 138: | Line 153: | ||
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} | |{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} | ||
| | | | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |AZnLOF 2020 | | bgcolor="#D0E7FF" align="center" |AZnLOF 2020 | ||
Line 145: | Line 161: | ||
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} | |{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} | ||
| | | | ||
+ | |||
|- bgcolor="EEFFFF" | |- bgcolor="EEFFFF" | ||
| bgcolor="#D0E7FF" align="center" |AZnLOF 2035 | | bgcolor="#D0E7FF" align="center" |AZnLOF 2035 | ||
Line 152: | Line 169: | ||
|A | |A | ||
| | | | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |AZnLOF 2070 | | bgcolor="#D0E7FF" align="center" |AZnLOF 2070 | ||
Line 159: | Line 177: | ||
|A | |A | ||
| | | | ||
+ | |||
|- bgcolor="EEFFFF" | |- bgcolor="EEFFFF" | ||
| bgcolor="#D0E7FF" align="center" |AZnLOF 5510 | | bgcolor="#D0E7FF" align="center" |AZnLOF 5510 | ||
Line 166: | Line 185: | ||
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} | |{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} | ||
| | | | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |UVN30-0.8 | | bgcolor="#D0E7FF" align="center" |UVN30-0.8 | ||
Line 173: | Line 193: | ||
| | | | ||
|{{rl|Stepper Recipes|Negative Resist (ASML DUV)}} | |{{rl|Stepper Recipes|Negative Resist (ASML DUV)}} | ||
+ | |||
|- bgcolor="EEFFFF" | |- bgcolor="EEFFFF" | ||
| bgcolor="#D0E7FF" align="center" |SU-8 2005,2010, 2015 | | bgcolor="#D0E7FF" align="center" |SU-8 2005,2010, 2015 | ||
Line 180: | Line 201: | ||
|A | |A | ||
| | | | ||
+ | |||
|- | |- | ||
| bgcolor="#D0E7FF" align="center" |SU-8 2075 | | bgcolor="#D0E7FF" align="center" |SU-8 2075 | ||
Line 187: | Line 209: | ||
|A | |A | ||
| | | | ||
+ | |||
|- bgcolor="EEFFFF" | |- bgcolor="EEFFFF" | ||
| bgcolor="#D0E7FF" align="center" |NR9-1000,3000,6000PY | | bgcolor="#D0E7FF" align="center" |NR9-1000,3000,6000PY | ||
Line 194: | Line 217: | ||
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} | |{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} | ||
| | | | ||
+ | |||
+ | |||
|- | |- | ||
+ | ! bgcolor="#D0E7FF" align="center" | '''Anti-Reflection Coatings''' | ||
+ | {{LithRecipe Table}} | ||
+ | |||
+ | |- bgcolor="EEFFFF" | ||
+ | | bgcolor="#D0E7FF" align="center" |DUV42-P | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |{{rl|Stepper Recipes|DUV-42P}} | ||
+ | |||
+ | |- | ||
+ | | bgcolor="#D0E7FF" align="center" |DS-K101-304 | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | | | ||
+ | |{{rl|Stepper Recipes|DS-K101-304}} | ||
− | ! bgcolor="#D0E7FF" align="center" | | + | |- |
+ | ! bgcolor="#D0E7FF" align="center" | ''' ''' | ||
{{LithRecipe Table}} | {{LithRecipe Table}} | ||
|} | |} | ||
+ | <!-- end Litho Recipes table --> | ||
==E-Beam Lithography Recipes== | ==E-Beam Lithography Recipes== |
Revision as of 12:15, 19 November 2019
General Information
This page contains information and links to recipes/datasheets spin-coated materials used in the facility. In general, the following information is provided for the following materials:
- Photoresists:
- Photo Lithography Recipe section: Has links to nominal recipes (spin, bake, exposure, develop etc.) to provide the user with starting points are found in the. Substrate, surface materials, pattern size can often affect process parameters.
- Stocked Lithography Chemical + Datasheets: Lists all stocked photolith. chemicals, and links to the chemical's application notes/datasheet, which detail the spin curves and nominal processes.
- E-beam Lithography Resists: Links to nominal recipes may be provided in the E-Beam Lithography Recipe Section. Substrates and patterns play a large role in process parameters. Datasheets provided for reference.
- Nanoimprinting Resists: Datasheets are provided. Any recipes provided are for use in the Nano-Imprint (Nanonex NX2000) system only and are found in the Nanoimprinting Recipes section.
- Underlayers: These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist. Datasheets are provided and some recipes are found in the Lift-Off Techniques section.
- Holography: For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square. Recipes for silicon substrates are provided in the Holography section.
- Anti-Reflection Coatings: Bottom Anti-Reflection Coatings (BARC) are used in the stepper systems, underneath the resists to eliminate substrate reflections that can affect resolution and repeatability for small, near resolution limited, feature sizes. Recipes using these materials are found within the photoresist recipes themselves. Datasheets are provided for reference on use of the materials.
- Contrast Enhancement Materials (CEM): Used for resolution enhancement. Not for use in contact aligners. Recipes using these materials are found within the photoresist recipes themselves. Datasheets also provided.
- Adhesion Promoters: These are used to improve wetting of photoresists to your substrate. Datasheets are provided on use of these materials.
- Low-K Spin-on Dielectrics: Datasheets are provided for BCB, Photo-BCB, and SOG for reference on use. Some recipes are provided in the Low-K Spin-On Dielectric Recipes section.
- Developers and Removers: Remover and Photoresist Strippers are used to dissolve PR during lift-off or after etching. Datasheets provided for reference.
Photolithography Recipes
- R = Recipe is available. Clicking this link will take you to the recipe.
- A = Material is available for use, but no recipes are provided.
Photolithography Recipes
| ||||||||
---|---|---|---|---|---|---|---|---|
Contact Aligners | Steppers
| |||||||
Positive Resists | SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg)
| ||
AZ4110 | R | R | A | A | ||||
AZ4210 | R | R | A | A | ||||
AZ4330RS | R | R | A | A | ||||
OCG 825-35CS | A | A | A | A | ||||
SPR 950-0.8 | A | A | A | A | ||||
SPR 955 CM-0.9 | A | R | R | R | ||||
SPR 955 CM-1.8 | A | A | R | R | ||||
SPR 220-3.0 | R | R | R | R | ||||
SPR 220-7.0 | R | R | R | R | ||||
THMR-IP3600 HP D | A | A | ||||||
UV6-0.8 | R | |||||||
UV210-0.3 | R | |||||||
UV26-2.5 | A
| |||||||
Negative Resists | SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg)
| ||
AZ5214-EIR | R | R | R | R | ||||
AZnLOF 2020 | R | R | R | R | ||||
AZnLOF 2035 | A | A | A | A | ||||
AZnLOF 2070 | A | A | A | A | ||||
AZnLOF 5510 | A | A | R | R | ||||
UVN30-0.8 | R | |||||||
SU-8 2005,2010, 2015 | A | R | A | A | ||||
SU-8 2075 | A | A | A | A | ||||
NR9-1000,3000,6000PY | R | R | A | R |
| |||
Anti-Reflection Coatings | SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg)
| ||
DUV42-P | R | |||||||
DS-K101-304 | R | |||||||
SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg)
|
E-Beam Lithography Recipes
- Under Development.
Automated Coat/Develop System Recipes (S-Cubed Flexi)
Recipes pre-loaded on the S-Cubed Flexi automated coat/bake/develop system. Only staff may write new recipes, contact the tool supervisor for more info.
To Be Added
Nanoimprinting Recipes
- Thermal Nanoimprint Process and Tutorial
- UV-Cure Low Temp, Low Pressure, Soft-Stamp Nanoimprint Process
Holography Recipes
- Standard Holography Process - on SiO2 on Si
- Holography Process Variations - Set-up Angle - Etching into SiO2 and Si
- Etch SiO2 Nano-structure - Changing Side-wall Angle - Etching into Si with a different line-width
- Reduce SiO2 Nanowire Diameter - Thermal Oxidation - Vapor HF Etching
Low-K Spin-On Dielectric Recipes
Lift-Off Techniques
- Description/Tutorial
- Lift-Off Tutorial and Limits
- How it works, process limits and considerations for designing your process
- I-Line Lift-Off: Bi-Layer Process with PMGI Underlayer and Contact Aligner
- DUV Lift-Off: UV6 Imaging Resist + PMGI Underlayer
Chemicals Stocked + Datasheets
The following is a list of the lithography chemicals we have available in the lab, with links to the datasheets for each. The datasheets will often have important processing info such as spin-speed vs. thickness curves, typical process parameters, bake temps/times etc.