Difference between revisions of "Lithography Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(→‎Chemical Datasheets: Added Anchors for every section)
Line 24: Line 24:
 
|- valign="top"
 
|- valign="top"
 
| width="400" |
 
| width="400" |
;<div id="PosPR"><big>Positive Photoresists</big></div>
+
;<div id="PositivePR"><big>Positive Photoresists</big></div>
 
'''''i-line and broadband'''''
 
'''''i-line and broadband'''''
 
*{{fl|AXP4000pb-Datasheet.pdf|AZP4000 (AZ4110, AZ4210, AZ4330)}}
 
*{{fl|AXP4000pb-Datasheet.pdf|AZP4000 (AZ4110, AZ4210, AZ4330)}}
Line 40: Line 40:
   
   
;<big>Negative Photoresists</big>
+
;<div id="NegativePR"><big>Negative Photoresists</big></div>
 
'''''i-line and broadband'''''
 
'''''i-line and broadband'''''
 
*{{fl|AZ5214-Negative-Resist-Datasheet.pdf|AZ5214}}
 
*{{fl|AZ5214-Negative-Resist-Datasheet.pdf|AZ5214}}
Line 54: Line 54:
   
   
;<big>Underlayers</big>
+
;<div id="Underlayers"><big>Underlayers</big></div>
   
 
*{{fl|PMGI-Underlayer-Datasheet.pdf|PMGI (PMGI SF3,5,8,11,15)}}
 
*{{fl|PMGI-Underlayer-Datasheet.pdf|PMGI (PMGI SF3,5,8,11,15)}}
Line 60: Line 60:
   
   
;<big>E-beam resists</big>
+
;<div id="EBLPR"><big>E-beam resists</big></div>
   
 
*{{fl|PMMA-E-Beam-Resist-Datasheet.pdf|PMMA (PMMA, P(MMA-MAA) copolymer)}}
 
*{{fl|PMMA-E-Beam-Resist-Datasheet.pdf|PMMA (PMMA, P(MMA-MAA) copolymer)}}
Line 66: Line 66:
   
   
;<big>Nanoimprinting</big>
+
;<div id="NanoImprinting"><big>Nanoimprinting</big></div>
   
 
*{{fl|NX1020-Nanoimprinting-Datasheet.pdf|NX1020}}
 
*{{fl|NX1020-Nanoimprinting-Datasheet.pdf|NX1020}}
Line 74: Line 74:
   
 
|
 
|
;<big>Contrast Enhancement Materials</big>
+
;<div id="ContrastEnhancement"><big>Contrast Enhancement Materials</big></div>
   
 
*{{fl|CEM365iS-Contrast-Enhancement-Datasheet.pdf|CEM365iS}}
 
*{{fl|CEM365iS-Contrast-Enhancement-Datasheet.pdf|CEM365iS}}
   
   
;<big>Anti-Reflection Coatings</big>
+
;<div id="AntiReflectionCoatings"><big>Anti-Reflection Coatings</big></div>
   
 
*{{fl|XHRiC-Anti-Reflective-Coating.pdf|XHRiC (i-line)}}
 
*{{fl|XHRiC-Anti-Reflective-Coating.pdf|XHRiC (i-line)}}
Line 87: Line 87:
   
   
;<big>Adhesion Promoters</big>
+
;<div id="AdhesionPromoters"><big>Adhesion Promoters</big></div>
   
 
*HMDS
 
*HMDS
Line 95: Line 95:
   
   
;<big>BCB and SOG</big>
+
;<div id="BCBandSOG"><big>BCB and SOG</big></div>
  +
  +
'Benzocyclobutane and Spin-on Glass'
   
 
*{{fl|BCB-cyclotene-3000-revA.pdf|BCB, Cyclotene 3022-46(Not Photosensitive)}}
 
*{{fl|BCB-cyclotene-3000-revA.pdf|BCB, Cyclotene 3022-46(Not Photosensitive)}}
Line 103: Line 105:
   
   
;<big>Developers</big>
+
;<div id="Developers"><big>Developers</big></div>
   
 
*{{fl|AZ400K-Developer-Datasheet.pdf|AZ400K (AZ400K, AZ400K1:4)}}
 
*{{fl|AZ400K-Developer-Datasheet.pdf|AZ400K (AZ400K, AZ400K1:4)}}
Line 112: Line 114:
   
   
;<big>Photoresist Removers</big>
+
;<div id="PRRemovers"><big>Photoresist Removers</big></div>
   
 
*{{fl|1165-Resist-Remover.pdf|1165}}
 
*{{fl|1165-Resist-Remover.pdf|1165}}

Revision as of 09:39, 1 September 2017

General Information

This page contains information and links to recipes/datasheets spin-coated materials used in the facility. In general, the following information is provided for the following materials:

  • Photoresists: Links to nominal recipes to provide the user with starting points are found in the Photo Lithography Recipe section. Substrate, surface materials, pattern size can often affect process parameters. Datasheets provided for reference.
  • E-beam Lithography Resists: Links to nominal recipes may be provided in the E-Beam Lithography Recipe Section. Substrates and patterns play a large role in process parameters. Datasheets provided for reference.
  • Underlayers: These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist. Datasheets are provided and some recipes are found in the Lift-Off Techniques section.
  • Nanoimprinting Resists: Datasheets are provided. Any recipes provided are for use in the Nanonex NX2000 system only and are found in the Nanoimprint section.
  • Holography: For 1-D and 2-D gratings with 220nm nominal period, available on substrates up to 1 inch square. Recipe on silicon provided in the holography section.
  • Anti-Reflection Coatings: These are used in the stepper systems, underneath the resists to eliminate substrate reflections that can affect resolution and repeatability for small, near resolution limited, feature sizes. Recipes using these materials are found within the photoresist recipes themselves. Datasheets are provided for reference on use of the materials.
  • Contrast Enhancement Materials (CEM): Used for resolution enhancement. Not for use in contact aligners. Recipes using these materials are found within the photoresist recipes themselves. Datasheets also provided.
  • Adhesion Promoters: Datasheets are provided on use of these materials.
  • Low-K Spin-on Dielectrics: Datasheets are provided for BCB, Phoot-BCB, and SOG for reference on use. Some recipes are provided in the Low-K section.
  • Developers and Removers: Datasheets provided for reference.

Lift-Off Techniques

Chemical Datasheets

Positive Photoresists

i-line and broadband

DUV-248nm


Negative Photoresists

i-line and broadband

DUV-248nm


Underlayers


E-beam resists


Nanoimprinting
Contrast Enhancement Materials


Anti-Reflection Coatings


Adhesion Promoters


BCB and SOG

'Benzocyclobutane and Spin-on Glass'


Developers


Photoresist Removers

Photolithography Recipes

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.


Photolithography Recipes

Contact Aligners Steppers
Positive Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


AZ4110 R R A A
AZ4210 R R A A
AZ4330RS R R A A
OCG 825-35CS A A A A
SPR 950-0.8 A A A A
SPR 955 CM-0.9 A R R R
SPR 955 CM-1.8 A A R R
SPR 220-3.0 R R R R
SPR 220-7.0 R R R R
THMR-IP3600 HP D

A A
UV6-0.8 R
UV210-0.3 R
PEK-162C1 A
Negative Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


AZ5214-EIR R R R R
AZnLOF 2020 R R R R
AZnLOF 2035 A A A A
AZnLOF 2070 A A A A
AZnLOF 5510 A A R R
UVN2300-0.5 R
SU-8 2005,2010, 2015 A R A A
SU-8 2075 A A A A
NR9-1000,3000,6000PY A A A R
SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
MLA150
(Heidelberg)


E-Beam Lithography Recipes

  • Under Development

Nanoimprinting

Holography Recipes

Low-K Dielectric