Difference between revisions of "Lithography Recipes"
Jump to navigation
Jump to search
(→Chemicals Stocked + Datasheets: added model of XHRIC-11) |
(→Lift-Off Techniques: changed to Liftoff Recipes) |
||
Line 312: | Line 312: | ||
*{{fl|512B-Application-Data-Bake-revA.pdf|SOG (T512B)}} | *{{fl|512B-Application-Data-Bake-revA.pdf|SOG (T512B)}} | ||
− | ==Lift-Off | + | ==Lift-Off Recipes== |
*{{fl|Liftoff-Techniques.pdf|Lift-Off Description/Tutorial}} | *{{fl|Liftoff-Techniques.pdf|Lift-Off Description/Tutorial}} |
Revision as of 17:34, 18 September 2020
General Information
This page contains information and links to recipes/datasheets spin-coated materials used in the facility.
Table of Contents |
---|
|
Photolithography Recipes
- R = Recipe is available. Clicking this link will take you to the recipe.
- A = Material is available for use, but no recipes are provided.
Photolithography Recipes
| ||||||
---|---|---|---|---|---|---|
Contact Aligner Recipes | Stepper Recipes | Other | ||||
Positive Resists | SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg) |
AZ4110 | R | R | A | A | ||
AZ4210 | R | R | A | A | ||
AZ4330RS | R | R | A | A | ||
AZ4620 | A | |||||
OCG 825-35CS | A | A | A | A | ||
SPR 950-0.8 | A | A | A | A | ||
SPR 955 CM-0.9 | A | R | R | R | ||
SPR 955 CM-1.8 | A | A | R | R | ||
SPR 220-3.0 | R | R | R | R | ||
SPR 220-7.0 | R | R | R | R | ||
THMR-IP3600 HP D | A | A | A | |||
UV6-0.8 | R | |||||
UV210-0.3 | R | |||||
UV26-2.5 | A | |||||
Negative Resists | SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg) |
AZ5214-EIR | R | R | R | R | ||
AZnLOF 2020 | R | R | R | R | ||
AZnLOF 2035 | A | A | A | A | ||
AZnLOF 2070 | A | A | A | A | ||
AZnLOF 5510 | A | A | R | R | ||
UVN30-0.8 | R | |||||
SU-8 2005,2010, 2015 | A | R | A | A | ||
SU-8 2075 | A | A | A | A | ||
NR9-1000,3000,6000PY | R | R | A | R | ||
Anti-Reflection Coatings | SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg) |
DUV42-P | R | |||||
DS-K101-304 | R | |||||
SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg) |
E-Beam Lithography Recipes (JEOL JBX-6300FS)
- Under Development.
FIB Lithography Recipes (Raith Velion)
To Be Added
Automated Coat/Develop System Recipes (S-Cubed Flexi)
Recipes pre-loaded on the S-Cubed Flexi automated coat/bake/develop system. Only staff may write new recipes, contact the tool supervisor for more info.
To Be Added
Nanoimprinting Recipes
- Thermal Nanoimprint Process and Tutorial
- UV-Cure Low Temp, Low Pressure, Soft-Stamp Nanoimprint Process
Holography Recipes
- Standard Holography Process - on SiO2 on Si
- Holography Process Variations - Set-up Angle - Etching into SiO2 and Si
- Etch SiO2 Nano-structure - Changing Side-wall Angle - Etching into Si with a different line-width
- Reduce SiO2 Nanowire Diameter - Thermal Oxidation - Vapor HF Etching
Low-K Spin-On Dielectric Recipes
Lift-Off Recipes
- Lift-Off Description/Tutorial
- How it works, process limits and considerations for designing your process
- I-Line Lift-Off: Bi-Layer Process with PMGI Underlayer and Contact Aligner
- DUV Lift-Off: UV6 Imaging Resist + PMGI Underlayer
Chemicals Stocked + Datasheets
The following is a list of the lithography chemicals we stock in the lab, with links to the datasheets for each. The datasheets will often have important processing info such as spin-speed vs. thickness curves, typical process parameters, bake temps/times etc.