Difference between revisions of "Lithography Recipes"
Jump to navigation
Jump to search
(Converted wall-of-text list into indented table of contents) |
|||
Line 1: | Line 1: | ||
==General Information== |
==General Information== |
||
− | This page contains information and links to recipes/datasheets spin-coated materials used in the facility. |
+ | This page contains information and links to recipes/datasheets spin-coated materials used in the facility. |
+ | {| class="wikitable" |
||
⚫ | |||
+ | |+ |
||
− | **[[#Photolithography_Recipes |Photo Lithography Recipe section]]: Has links to nominal recipes (spin, bake, exposure, develop etc.) to provide the user with starting points are found in the. Substrate, surface materials, pattern size can often affect process parameters. |
||
+ | !Table of Contents |
||
⚫ | |||
+ | |- |
||
− | *'''[[#EBLPR |E-beam Lithography Resists]]''': Links to nominal recipes may be provided in the [[#E-Beam_Lithography_Recipes | E-Beam Lithography Recipe Section]]. Substrates and patterns play a large role in process parameters. [[#EBLPR | Datasheets]] provided for reference. |
||
+ | | |
||
− | *'''[[#NanoImprinting |Nanoimprinting Resists]]''': Datasheets are provided. Any recipes provided are for use in the [[Nano-Imprint_(Nanonex_NX2000) | Nano-Imprint (Nanonex NX2000)]] system only and are found in the [[#Nanoimprinting_Recipes | Nanoimprinting Recipes section]]. |
||
⚫ | |||
+ | **[[#Photolithography_Recipes |Photo Lithography Recipe section]] |
||
+ | ***''Has links to starting recipes (spin, bake, exposure, develop etc.).'' |
||
+ | ***''Substrate, surface materials, pattern size can often affect process parameters. Users may need to run Focus/Exposure Arrays/Matrix (FEA's/FEM's) with these processes to achieve high-resolution.'' |
||
+ | **[[#PositivePR |Stocked Lithography Chemical + Datasheets]] |
||
⚫ | |||
+ | *'''[[#EBLPR |E-beam Lithography Resists]]''' |
||
+ | **[[#E-Beam_Lithography_Recipes |E-Beam Lithography Recipes]] |
||
+ | ***''Has links to starting recipes. Substrates and patterns play a large role in process parameters.'' |
||
+ | **[[#EBLPR |EBL Photoresist Datasheets]] |
||
+ | ***''Provided for reference, also showing starting recipes and usage info.'' |
||
+ | *'''[[#NanoImprinting |Nanoimprinting Resists]]''' |
||
+ | **''Datasheets are provided with starting recipes and usage info.'' |
||
+ | **''Recipes provided are for use in the [[Nano-Imprint_(Nanonex_NX2000) |Nano-Imprint (Nanonex NX2000)]] system only.'' |
||
+ | *'''[[#Underlayers |Underlayers]]''' |
||
− | *'' |
+ | **''These are used beneath resists for both adhesive purposes and to enable bi-layer lift-off profiles for use with photoresist.'' |
⚫ | |||
+ | **''Datasheets are provided.'' |
||
⚫ | *'' |
||
+ | *[[#Lift-Off_Techniques |'''Lift-Off Techniques''']] |
||
− | *'''[[#ContrastEnhancement |Contrast Enhancement Materials (CEM)]]''': Used for resolution enhancement. Not for use in contact aligners. Recipes using these materials are found within the [[#Photolithography_Recipes |photoresist recipes]] themselves. Datasheets also provided. |
||
+ | **''Verified Recipes for lift-off using various photolith. tools'' |
||
⚫ | |||
+ | **''General educational description of this technique and it's limitations/considerations.'' |
||
+ | *'''[[Lithography Recipes#Holography Recipes|Holography]]''' |
||
⚫ | |||
+ | **''Recipes for silicon substrates are provided, and have been translated to other substrates by users.'' |
||
+ | *'''[[#AntiReflectionCoatings |Anti-Reflection Coatings]]''': |
||
+ | **[[#Photolithography_Recipes |The Photoresist Recipes]] section contains recipes using these materials. |
||
⚫ | |||
+ | **''Datasheets are provided for reference on use of the materials.'' |
||
+ | *'''[[#ContrastEnhancement |Contrast Enhancement Materials (CEM)]]''' |
||
+ | **[[#Photolithography_Recipes |The Photoresist Recipes]] section contains recipes using these materials. |
||
+ | **''Used for resolution enhancement. Not for use in contact aligners, typically used on I-Line Steppers.'' |
||
+ | **''Datasheets provided with usage info.'' |
||
+ | *'''[[#AdhesionPromoters |Adhesion Promoters]]''' |
||
⚫ | |||
+ | **''Datasheets are provided on use of these materials.'' |
||
− | *'''[[#SpinOnDielectrics |Low-K Spin-on Dielectrics]]''' |
+ | *'''[[#SpinOnDielectrics |Low-K Spin-on Dielectrics]]''' |
+ | **[[Lithography Recipes#SpinOnDielectrics|Spin-On Dielectrics]] |
||
⚫ | |||
+ | ***''Datasheets for BCB, Photo-BCB, and SOG (spin-on-glass) for reference on use.'' |
||
+ | **[[#Low-K_Spin-On_Dielectric_Recipes |Low-K Spin-On Dielectric Recipes]] |
||
+ | ***''Recipes for usage of some spin-on dielectrics.'' |
||
+ | *'''[[#Developers |Developers and Removers]]''' |
||
+ | **''Datasheets provided for reference.'' |
||
⚫ | |||
+ | |} |
||
==Photolithography Recipes== |
==Photolithography Recipes== |
||
Line 28: | Line 64: | ||
|- bgcolor="#D0E7FF" |
|- bgcolor="#D0E7FF" |
||
|<!-- INTENTIONALLY LEFT BLANK --><br> |
|<!-- INTENTIONALLY LEFT BLANK --><br> |
||
− | ! colspan="2" bgcolor="#D0E7FF" align="center" |'''[[Contact Alignment Recipes|Contact |
+ | ! colspan="2" bgcolor="#D0E7FF" align="center" |'''[[Contact Alignment Recipes|<big>Contact Aligner Recipes</big>]]''' |
− | ! colspan="3" bgcolor="#D0E7FF" align="center" |'''[[Stepper Recipes|Steppers]]''' |
+ | ! colspan="3" bgcolor="#D0E7FF" align="center" |'''[[Stepper Recipes|<big>Steppers Recipes</big>]]''' |
− | |||
|- |
|- |
||
! width="150" bgcolor="#D0E7FF" align="center" |'''Positive Resists''' |
! width="150" bgcolor="#D0E7FF" align="center" |'''Positive Resists''' |
||
{{LithRecipe Table}} |
{{LithRecipe Table}} |
||
− | |||
− | |||
|- |
|- |
||
| bgcolor="#D0E7FF" align="center" |AZ4110 |
| bgcolor="#D0E7FF" align="center" |AZ4110 |
||
Line 140: | Line 173: | ||
| bgcolor="EEFFFF" | |
| bgcolor="EEFFFF" | |
||
| bgcolor="EEFFFF" |A |
| bgcolor="EEFFFF" |A |
||
− | |||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" |'''Negative Resists''' |
! bgcolor="#D0E7FF" align="center" |'''Negative Resists''' |
||
{{LithRecipe Table}} |
{{LithRecipe Table}} |
||
− | |||
|- bgcolor="EEFFFF" |
|- bgcolor="EEFFFF" |
||
| bgcolor="#D0E7FF" align="center" |AZ5214-EIR |
| bgcolor="#D0E7FF" align="center" |AZ5214-EIR |
||
Line 217: | Line 248: | ||
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} |
|{{rl|Stepper Recipes|Negative Resist (AutoStep 200)}} |
||
| |
| |
||
− | |||
|- |
|- |
||
! bgcolor="#D0E7FF" align="center" | '''Anti-Reflection Coatings''' |
! bgcolor="#D0E7FF" align="center" | '''Anti-Reflection Coatings''' |
||
− | {{LithRecipe Table}} |
+ | {{LithRecipe Table}} |
− | |||
|- bgcolor="EEFFFF" |
|- bgcolor="EEFFFF" |
||
| bgcolor="#D0E7FF" align="center" |DUV42-P |
| bgcolor="#D0E7FF" align="center" |DUV42-P |
||
Line 240: | Line 269: | ||
|- |
|- |
||
− | ! bgcolor="#D0E7FF" align="center" | |
+ | ! bgcolor="#D0E7FF" align="center" | |
− | {{LithRecipe Table}} |
+ | {{LithRecipe Table}} |
− | |||
− | |||
|} |
|} |
||
<!-- end Litho Recipes table --> |
<!-- end Litho Recipes table --> |
Revision as of 14:01, 17 June 2020
General Information
This page contains information and links to recipes/datasheets spin-coated materials used in the facility.
Table of Contents |
---|
|
Photolithography Recipes
- R = Recipe is available. Clicking this link will take you to the recipe.
- A = Material is available for use, but no recipes are provided.
Photolithography Recipes
| ||||||||
---|---|---|---|---|---|---|---|---|
Contact Aligner Recipes | Steppers Recipes | |||||||
Positive Resists | SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg) | ||
AZ4110 | R | R | A | A | ||||
AZ4210 | R | R | A | A | ||||
AZ4330RS | R | R | A | A | ||||
OCG 825-35CS | A | A | A | A | ||||
SPR 950-0.8 | A | A | A | A | ||||
SPR 955 CM-0.9 | A | R | R | R | ||||
SPR 955 CM-1.8 | A | A | R | R | ||||
SPR 220-3.0 | R | R | R | R | ||||
SPR 220-7.0 | R | R | R | R | ||||
THMR-IP3600 HP D | A | A | ||||||
UV6-0.8 | R | |||||||
UV210-0.3 | R | |||||||
UV26-2.5 | A | |||||||
Negative Resists | SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg) | ||
AZ5214-EIR | R | R | R | R | ||||
AZnLOF 2020 | R | R | R | R | ||||
AZnLOF 2035 | A | A | A | A | ||||
AZnLOF 2070 | A | A | A | A | ||||
AZnLOF 5510 | A | A | R | R | ||||
UVN30-0.8 | R | |||||||
SU-8 2005,2010, 2015 | A | R | A | A | ||||
SU-8 2075 | A | A | A | A | ||||
NR9-1000,3000,6000PY | R | R | A | R | ||||
Anti-Reflection Coatings | SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg) | ||
DUV42-P | R | |||||||
DS-K101-304 | R | |||||||
SUSS MJB-3 | SUSS MA-6 | Stepper 1 (GCA 6300) |
Stepper 2 (AutoStep 200) |
Stepper 3 (ASML DUV) |
MLA150 (Heidelberg) |
E-Beam Lithography Recipes
- Under Development.
Automated Coat/Develop System Recipes (S-Cubed Flexi)
Recipes pre-loaded on the S-Cubed Flexi automated coat/bake/develop system. Only staff may write new recipes, contact the tool supervisor for more info.
To Be Added
Nanoimprinting Recipes
- Thermal Nanoimprint Process and Tutorial
- UV-Cure Low Temp, Low Pressure, Soft-Stamp Nanoimprint Process
Holography Recipes
- Standard Holography Process - on SiO2 on Si
- Holography Process Variations - Set-up Angle - Etching into SiO2 and Si
- Etch SiO2 Nano-structure - Changing Side-wall Angle - Etching into Si with a different line-width
- Reduce SiO2 Nanowire Diameter - Thermal Oxidation - Vapor HF Etching
Low-K Spin-On Dielectric Recipes
Lift-Off Techniques
- Description/Tutorial
- Lift-Off Tutorial and Limits
- How it works, process limits and considerations for designing your process
- I-Line Lift-Off: Bi-Layer Process with PMGI Underlayer and Contact Aligner
- DUV Lift-Off: UV6 Imaging Resist + PMGI Underlayer
Chemicals Stocked + Datasheets
The following is a list of the lithography chemicals we have available in the lab, with links to the datasheets for each. The datasheets will often have important processing info such as spin-speed vs. thickness curves, typical process parameters, bake temps/times etc.