Difference between revisions of "Lift-Off with DUV Imaging + PMGI Underlayer"
Jump to navigation
Jump to search
(added PMGI dissolution rate) |
(Acknowledge development by demis) |
||
Line 1: | Line 1: | ||
+ | Developed by Demis D. John, ~2017-2019 |
||
This process is intended for Deep-UV Exposure on the ASML DUV Stepper. PMGI is used as the underlayer, which is exposed at the same time as the imaging resist. |
This process is intended for Deep-UV Exposure on the ASML DUV Stepper. PMGI is used as the underlayer, which is exposed at the same time as the imaging resist. |
||
Line 41: | Line 42: | ||
*Lift-off in NMP, facing down or vertical. |
*Lift-off in NMP, facing down or vertical. |
||
− | == |
+ | ==Data== |
• For PMGI Baked at 220°C for 3min, the PMGI dissolves in AZ 300MIF at a rate of approximately ~600nm/min. |
• For PMGI Baked at 220°C for 3min, the PMGI dissolves in AZ 300MIF at a rate of approximately ~600nm/min. |
||
Revision as of 02:31, 30 November 2019
Developed by Demis D. John, ~2017-2019
This process is intended for Deep-UV Exposure on the ASML DUV Stepper. PMGI is used as the underlayer, which is exposed at the same time as the imaging resist.
This process uses PMGI SF-5 @ 4krpm, which spins to about 130nm (maximum metal thickness = 130nm/3 ≈ 45nm) and undercuts laterally about 130-140nm (minimum gap between metals = (2 x 140nm) + 30nm ≈ 350nm).
Adjust spin speed or switch to a different PMGI formulation to tailor the underlayer thickness to your desired metal thickness.
Tips
Please see our [Bi-Layer Lift-Off Tutorial] to understand the limitations and requirements for good lift-off.
- Remember that gaps in between adjacent metal traces can lift-off during the develop!
- Need underlayer thickness 2x to 3x the desired metal thickness.
- The underlayer will develop laterally from both sides which can lift-off the imaging resist, so:
- Minimum gap between adjacent metals should then be: less than 0.5 * underlayer thickness
- Want at least 30-50nm of underlayer width left to support the imaging resist, so the PR doesn't fall over/collapse.
- Make sure to use a vertical evaporation - EBeam4 or EBeam1. EBeam3 is not vertical.
Suggested Process for Liftoff
- De-H2O Bake (eg. 220°C, 1m+). Optionally Oxygen ash instead (faster and more effective).
- Spin PMGI SF-5 @ 4krpm (rcp 7)
- --> POLOS underside clean: 2000rpm, ACE/ISO/N2
- PMGI-Bake: 220°C, 3min (BrewerSci lift-pin hotplate). Can just place wafer directly onto hotplate surface. Optionally can use lift-pins & Recipe "00 220deg, 3min Vac"; Enable Vacuum with overhead valve, only for wafer landing and then turn off to prevent sliding.
- Spin UV-6-0.8 @ rcp 6 (3.5krpm)
- --> POLOS underside clean: 2000rpm, ACE/ISO/N2
- Soft-Bake = 135°C, 1min (builtin hotplate)
- (check underside for particulates)
- ASML Exposure
- Default: Exp = 37.5mJ // foc = –0.10
- Try this exposure dose - might need to do a FocArray (smaller Image Distribution eg. 5x5) to find proper exposure.
- PEB = 135°C, 1.5min (built-in hotplate)
- Dev (300MiF) = 50sec (CRITICAL time)
- --> with cassette & H2O rinse dish prepared
- --> not stirring, instead very slow/gentle lift/drop at various angles or gentle swish just to mix developer slightly.
- DI rinse : very Gently! Dunk into prepared DI dish, and dump/fill gently 2x. Don’t allow direct hard water to hit PR surface.
- PEii Technics O2: 30sec. May increase feature size openings.
- Metal Evaporation - EBeam#4 or EBeam#1 vertical/4-inch holder
- Lift-off in NMP, facing down or vertical.
Data
• For PMGI Baked at 220°C for 3min, the PMGI dissolves in AZ 300MIF at a rate of approximately ~600nm/min.
Images / Examples