LegacyTable

From UCSB Nanofab Wiki
Revision as of 17:19, 18 July 2013 by Thibeault (talk | contribs) (Created page with "== Legacy Table == {{Recipe Table Explanation}} {| border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" class="wikitable" |- bgcolor="#...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Legacy Table

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.


E-Beam Lithography Recipes

Contact Aligners Steppers Flood Expose E-Beam Lithography
Positive Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
DUV Flood Field Emission SEM 1
(FEI Sirion)
E-Beam Lithography System
(JEOL JBX-6300FS)
AZ4110 R R A A
AZ4210 R R A A



AZ4330RS R R A A
OCG 825-35CS A A A A



SPR 950-0.8 A A A A
SPR 955 CM-0.9 A A R R



SPR 955 CM-1.8 A A R R
SPR 220-3.0 R R R R



SPR 220-7.0 R R R R
THMR-IP3600 HP D

A A



UV6-0.7 R
UV210-0.3 R
Negative Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
DUV Flood Field Emission SEM 1
(FEI Sirion)
E-Beam Lithography System
(JEOL JBX-6300FS)
AZ5214-EIR R R R R
AZnLOF 2020 R R R R
AZnLOF 2035 A A A A
AZnLOF 2070 A A A A
AZnLOF 5510 A A R R
UVN2300-0.5 R
SU-8 2015 A A A A
Underlayers SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
DUV Flood Field Emission SEM 1
(FEI Sirion)
E-Beam Lithography System
(JEOL JBX-6300FS)
PMGI SF-11







PMGI SF-15
LOL 2000
XHRIC-11 (i-lineBARC)
AR-2 (DUV BARC)
DS-K101 (DUV BARC)
Overlayers SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
DUV Flood Field Emission SEM 1
(FEI Sirion)
E-Beam Lithography System
(JEOL JBX-6300FS)
CEM-365 IS
E-Beam Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
DUV Flood Field Emission SEM 1
(FEI Sirion)
E-Beam Lithography System
(JEOL JBX-6300FS)
 ??????
 ???????
Nanoimprint Resists SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
DUV Flood Field Emission SEM 1
(FEI Sirion)
E-Beam Lithography System
(JEOL JBX-6300FS)
MR-I 7020
Nanonex NX-1020
SUSS MJB-3 SUSS MA-6 Stepper 1
(GCA 6300)
Stepper 2
(AutoStep 200)
Stepper 3
(ASML DUV)
DUV Flood Field Emission SEM 1
(FEI Sirion)
E-Beam Lithography System
(JEOL JBX-6300FS)