Difference between revisions of "KLayout Design Tips"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(link to QNFCF Youtube videos on Cells)
(added author credit)
Line 42: Line 42:
 
If you do need to use a non-orthogonal array, make sure to use '''''Selection > Resolve Arrays''''' before submitting your design to the manufacturer/machine.
 
If you do need to use a non-orthogonal array, make sure to use '''''Selection > Resolve Arrays''''' before submitting your design to the manufacturer/machine.
   
=== Handling very large files ===
+
===Handling very large files===
 
If you will be generating millions of identical shapes (eg. repeating array of circles), the file size can quickly become enormous due to all the stored polygon points. You can reduce the number of polygon points stored by:
 
If you will be generating millions of identical shapes (eg. repeating array of circles), the file size can quickly become enormous due to all the stored polygon points. You can reduce the number of polygon points stored by:
   
# Reduce the number of points in each shape/circle if possible. Gentle corners will be rounded by the lithography resolution.
+
#Reduce the number of points in each shape/circle if possible. Gentle corners will be rounded by the lithography resolution.
# Use Cell instancing so that only one, or a few, polygons are defined, and that same polygon is then only referenced as a repeating Cell instance. (See above for tutorials).
+
#Use Cell instancing so that only one, or a few, polygons are defined, and that same polygon is then only referenced as a repeating Cell instance. (See above for tutorials).
# The OAS file type generates much smaller files, and most photomask vendors can accept this. Photomask vendors are used to handling large files.
+
#The OAS file type generates much smaller files, and most photomask vendors can accept this. Photomask vendors are used to handling large files.
# Photomask vendors are able to take multiple files and insert them into the final reticle – you just need to provide a clear schematic showing the exact insertion coordinates for each file (with respect to the origin of each file). They can also do some boolean operations (for a fee).
+
#Photomask vendors are able to take multiple files and insert them into the final reticle – you just need to provide a clear schematic showing the exact insertion coordinates for each file (with respect to the origin of each file). They can also do some boolean operations (for a fee).
  +
  +
''[[Demis D. John]], updated 2022-09''

Revision as of 18:55, 7 September 2022

Turn on Editing Mode

By default, KLayout might open as a "viewer" only, without draw-mode capbilities (no square/polygon/text buttons in the toolbar) and only ruler/zoom tools. Enable Editing mode as so:

  • Preferences > Editing mode > [√] Use Editing Mode by default, and restart the software.

Turn on the display of the Origin (0,0)

  • Preferences > Display > Background > Axis = change from the default "invisible", eg. "Lines".

Minimum Step-Size / Database Unit

  • The default minimum unit of 0.001 µm (1nm) is usually fine. Don't change this after drawing - all polygons will be scaled accordingly. If you need finer resolution: Before starting your design, set the Layout Properties > Database Unit to something smaller, eg. 0.0001 µm.

How to draw circles

  • You have to draw a square, and then apply the function Edit > Selection > Convert to PCell > Basic.CIRCLE. Sometimes these P-Cells don't convert properly at the photomask vendor, so make sure to run Edit > Selection > Convert to Static Cell or Flatten (which converts to a polygon) before sending to the vendor/machine.
    • Another way is to convert a square to a polygon directly with Edit>Selection>Round Corners function with Outer Corner Radius = the desired circle radius (radius is not changeable afterards in this method, but computation may be faster for a large number of objects).
    • Klayout doesn't natively support circles because the GDS file format does not have a "circle" primitive built-in, so instead it creates a polygon. Make sure you include enough polygon points, eg. 32. See the forum help pages on this for more info.

Cells & Instances of Cells

It is highly recommended that you understand and use the concept of "Cells" in your design. This is critical for direct-write machines (EBL, MLA, Mask-writing vendors), and if used properly, helps tremendously with programming the Stepper lithography machines. This functionality also circumvents many problems with enormous file sizes (due to huge numbers of identical polygons), by "pointing" to the same polygon only defined once in the file. Links to documentation below:

File Types

OASIS files tend to be much smaller than GDS files, and they also save the Layer Names (not just Layer Number). Most Photomask manufacturers accept this file type.

GDS files are considered "standard", but are somewhat antiquated, and lose the text names of layers between saves.

Alternatively, in KLayout the function File > Save Session will save the entire view including layer styles and window/zoom locations will be saved. You can share this file, as the entire design file is embedded within it, but it may not be as robust between KLayout versions.

DXF files coming from AutoCAD often are missing the "units", and may erroneously map millimeters to meters, causing your design to be 1000x too large. You can fix this in File > Reader Options > DXF, or simply instance the entire design into a new Cell with Magnification set to correct the scaling error. Also, AutoCAD allows for non-closed polygons, which are invalid shapes (even though the start/end points lie on top of each other, the shape is not technically "closed" unless you use polyline-edit "PEDIT" and intentionally Close them). The DXF Reader has some options to catch/fix these.

Non-Orthogonal Arrays

Arrays created with diagonal instancing (non-orthogonal arrays) can be incompatible with photomask vendor's mask writing software.

We recommend you avoid the grey X and Y fields shown below when creating arrays, as shown here:

Klayou screenshot showing non-orthogonal array definition

If you do need to use a non-orthogonal array, make sure to use Selection > Resolve Arrays before submitting your design to the manufacturer/machine.

Handling very large files

If you will be generating millions of identical shapes (eg. repeating array of circles), the file size can quickly become enormous due to all the stored polygon points. You can reduce the number of polygon points stored by:

  1. Reduce the number of points in each shape/circle if possible. Gentle corners will be rounded by the lithography resolution.
  2. Use Cell instancing so that only one, or a few, polygons are defined, and that same polygon is then only referenced as a repeating Cell instance. (See above for tutorials).
  3. The OAS file type generates much smaller files, and most photomask vendors can accept this. Photomask vendors are used to handling large files.
  4. Photomask vendors are able to take multiple files and insert them into the final reticle – you just need to provide a clear schematic showing the exact insertion coordinates for each file (with respect to the origin of each file). They can also do some boolean operations (for a fee).
Demis D. John, updated 2022-09