Difference between revisions of "ICP-PECVD (Unaxis VLR)"
(→Documentation: redlink the SOP, explain the purpose of the "procedure") |
|||
(18 intermediate revisions by 2 users not shown) | |||
Line 12: | Line 12: | ||
}} | }} | ||
=About= | =About= | ||
− | This system is configured as an ICP PECVD deposition tool with 1000 W ICP power, 600 W RF substrate power, and | + | This system is configured as an ICP PECVD deposition tool with 1000 W ICP power, 600 W RF substrate power, and 100°C-350°C operation. This chamber has 100% SiD<sub>4,</sub> N<sub>2</sub>, O<sub>2</sub>, and Ar for gas sources. The high density PECVD produces a more dense, higher quality SiO<sub>2</sub> and Si<sub>3</sub>N<sub>4</sub>, as compared with conventional PECVD. With the high density plasma, deposition of high quality films can be deposited as low as 100°C for processes requiring lower temperatures. Stress compensation for silicon nitride is characterized. |
===Cluster Configuration=== | ===Cluster Configuration=== | ||
Line 23: | Line 23: | ||
*1000W ICP source, 600W RF Sample Bias Power Supply | *1000W ICP source, 600W RF Sample Bias Power Supply | ||
− | * | + | *100 - 350°C sample temperature |
− | *100% | + | *100% SiD<sub>4</sub>, Ar, N<sub>2</sub>, O<sub>2</sub> |
*Multiple 4” diameter wafer capable system | *Multiple 4” diameter wafer capable system | ||
*Pieces possible by mounting or placing on 4 ” wafer | *Pieces possible by mounting or placing on 4 ” wafer | ||
Line 30: | Line 30: | ||
=Documentation= | =Documentation= | ||
− | *Operating Instructions | + | *[[Unaxis VLR ICP-PECVD - Std. Operating Procedure|Operating Instructions]] |
− | *[[ | + | *[[Unaxis wafer coating procedure]] - ''process flow for achieving high-quality coatings.'' |
− | *[ | + | **For particle counting procedure, see the [https://wiki.nanotech.ucsb.edu/wiki/Wafer_scanning_process_traveler Surfscan Scanning Procedure] |
== Recipes == | == Recipes == | ||
You can find recipes for this tool on the Wiki > Recipes > [https://wiki.nanotech.ucsb.edu/wiki/PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29 PECVD Recipes page] | You can find recipes for this tool on the Wiki > Recipes > [https://wiki.nanotech.ucsb.edu/wiki/PECVD_Recipes#ICP-PECVD_.28Unaxis_VLR.29 PECVD Recipes page] |
Revision as of 00:08, 16 July 2020
|
About
This system is configured as an ICP PECVD deposition tool with 1000 W ICP power, 600 W RF substrate power, and 100°C-350°C operation. This chamber has 100% SiD4, N2, O2, and Ar for gas sources. The high density PECVD produces a more dense, higher quality SiO2 and Si3N4, as compared with conventional PECVD. With the high density plasma, deposition of high quality films can be deposited as low as 100°C for processes requiring lower temperatures. Stress compensation for silicon nitride is characterized.
Cluster Configuration
A Deposition and Etch chamber are both attached to the same loadlock, allowing etching and deposition without breaking vacuum. Each chamber can be scheduled separately on SignupMonkey.
- PM3: ICP-PECVD Deposition (this page)
- PM1: ICP Etch (Unaxis VLR)
Detailed Specifications
- 1000W ICP source, 600W RF Sample Bias Power Supply
- 100 - 350°C sample temperature
- 100% SiD4, Ar, N2, O2
- Multiple 4” diameter wafer capable system
- Pieces possible by mounting or placing on 4 ” wafer
Documentation
- Operating Instructions
- Unaxis wafer coating procedure - process flow for achieving high-quality coatings.
- For particle counting procedure, see the Surfscan Scanning Procedure
Recipes
You can find recipes for this tool on the Wiki > Recipes > PECVD Recipes page