Difference between revisions of "Field Emission SEM 2 (JEOL 7600F)"

From UCSB Nanofab Wiki
Jump to: navigation, search
(added 25x25mm)
 
(One intermediate revision by one other user not shown)
Line 2: Line 2:
 
|picture=JeolFesem.jpg
 
|picture=JeolFesem.jpg
 
|type = Inspection, Test and Characterization
 
|type = Inspection, Test and Characterization
|super= Bill Mitchell
+
|super= Aidan Hopkins
 
|phone= (805)893-4974
 
|phone= (805)893-4974
 
|location=Bay 1
 
|location=Bay 1
|email=mitchell@ece.ucsb.edu
+
|email=hopkins@ece.ucsb.edu
 
|description = JEOL 7600F FESEM
 
|description = JEOL 7600F FESEM
 
|manufacturer = [http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopesSEM/FESEM/JSM7600F/tabid/544/Default.aspx JEOL USA Inc]
 
|manufacturer = [http://www.jeolusa.com/PRODUCTS/ElectronOptics/ScanningElectronMicroscopesSEM/FESEM/JSM7600F/tabid/544/Default.aspx JEOL USA Inc]
Line 12: Line 12:
 
}}
 
}}
 
= About =
 
= About =
The JEOL JSM-7600F FESEM is used for imaging a variety of samples made in the facility. For general specifications, see the link to the system above. Our system is equipped with a gentle-beam mode of operation where bias is put on the stage, allowing for high resolution imaging at low electron energies impinging the surface. This is especially useful for imaging low conductivity and insulating materials without the need for conductive layer coatings. The system can accept a 4” wafer, but only 50mm of the wafer is accessible with the stage movement. A retractable LABE detector is also installed for high resolution back-scattered electron imaging.
+
The JEOL JSM-7600F FESEM is used for imaging a variety of samples made in the facility. For general specifications, see the link to the system above. Our system is equipped with a gentle-beam mode of operation where bias is put on the stage, allowing for high resolution imaging at low electron energies impinging the surface. This is especially useful for imaging low conductivity and insulating materials without the need for conductive layer coatings.
  +
  +
The system can accept a 4” wafer, but only 50mm (approx. 25x25mm) of the wafer is accessible with the stage movement. A retractable LABE detector is also installed for high resolution back-scattered electron imaging.

Latest revision as of 09:16, 18 May 2018

Field Emission SEM 2 (JEOL 7600F)
JeolFesem.jpg
Tool Type Inspection, Test and Characterization
Location Bay 1
Supervisor Aidan Hopkins
Supervisor Phone (805) 893-2343
Supervisor E-Mail hopkins@ece.ucsb.edu
Description JEOL 7600F FESEM
Manufacturer JEOL USA Inc
Sign up for this tool


About

The JEOL JSM-7600F FESEM is used for imaging a variety of samples made in the facility. For general specifications, see the link to the system above. Our system is equipped with a gentle-beam mode of operation where bias is put on the stage, allowing for high resolution imaging at low electron energies impinging the surface. This is especially useful for imaging low conductivity and insulating materials without the need for conductive layer coatings.

The system can accept a 4” wafer, but only 50mm (approx. 25x25mm) of the wafer is accessible with the stage movement. A retractable LABE detector is also installed for high resolution back-scattered electron imaging.