Difference between revisions of "Dry Etching Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(Updated formatting- smaller font for model #, header colors)
m (corrected Row Bg colors)
Line 48: Line 48:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |Al
 
! bgcolor="#d0e7ff" align="center" |Al
 
|
 
|
Line 86: Line 86:
 
|
 
|
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |Cr
 
! bgcolor="#d0e7ff" align="center" |Cr
 
|
 
|
Line 124: Line 124:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |Ge
 
! bgcolor="#d0e7ff" align="center" |Ge
 
|
 
|
Line 162: Line 162:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |Ni
 
! bgcolor="#d0e7ff" align="center" |Ni
 
|
 
|
Line 181: Line 181:
 
|
 
|
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
  +
|- bgcolor="#eeffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |Pt
 
! bgcolor="#d0e7ff" align="center" |Pt
 
|
 
|
Line 200: Line 200:
 
|
 
|
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |Ru
 
! bgcolor="#d0e7ff" align="center" |Ru
 
|
 
|
Line 238: Line 238:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |Ta
 
! bgcolor="#d0e7ff" align="center" |Ta
 
|
 
|
Line 257: Line 257:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#eeffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |Ti
 
! bgcolor="#d0e7ff" align="center" |Ti
 
|
 
|
Line 276: Line 276:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub>
 
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub>
 
|
 
|
Line 314: Line 314:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |AlGaAs
 
! bgcolor="#d0e7ff" align="center" |AlGaAs
 
|
 
|
Line 352: Line 352:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |AlN
 
! bgcolor="#d0e7ff" align="center" |AlN
 
|
 
|
Line 390: Line 390:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |GaAs
 
! bgcolor="#d0e7ff" align="center" |GaAs
 
|
 
|
Line 409: Line 409:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#eeffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |GaN
 
! bgcolor="#d0e7ff" align="center" |GaN
 
|
 
|
Line 428: Line 428:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |GaSb
 
! bgcolor="#d0e7ff" align="center" |GaSb
 
|
 
|
Line 466: Line 466:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |InGaAlAs
 
! bgcolor="#d0e7ff" align="center" |InGaAlAs
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
Line 485: Line 485:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#eeffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |InGaAsP
 
! bgcolor="#d0e7ff" align="center" |InGaAsP
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
Line 504: Line 504:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |InP
 
! bgcolor="#d0e7ff" align="center" |InP
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
Line 523: Line 523:
 
|
 
|
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
  +
|- bgcolor="#eeffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |ITO
 
! bgcolor="#d0e7ff" align="center" |ITO
 
|{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}}
 
|{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}}
Line 542: Line 542:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
!Photoresist
 
!Photoresist
 
& ARC
 
& ARC
Line 562: Line 562:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#eeffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |SiC
 
! bgcolor="#d0e7ff" align="center" |SiC
 
|
 
|
Line 581: Line 581:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |SiN
 
! bgcolor="#d0e7ff" align="center" |SiN
 
|
 
|
Line 619: Line 619:
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}}
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}}
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |SiOxNy
 
! bgcolor="#d0e7ff" align="center" |SiOxNy
 
|
 
|
Line 638: Line 638:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#eeffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub>
 
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub>
 
|
 
|
Line 657: Line 657:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |TiN
 
! bgcolor="#d0e7ff" align="center" |TiN
 
|
 
|
Line 695: Line 695:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
! bgcolor="#d0e7ff" align="center" |W-TiW
 
! bgcolor="#d0e7ff" align="center" |W-TiW
 
|
 
|
Line 733: Line 733:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |ZnS
 
! bgcolor="#d0e7ff" align="center" |ZnS
 
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
 
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
Line 752: Line 752:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#eeffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |ZnSe
 
! bgcolor="#d0e7ff" align="center" |ZnSe
 
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
 
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
Line 771: Line 771:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#ffffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub>
 
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub>
 
|
 
|
Line 790: Line 790:
 
|
 
|
 
|A
 
|A
  +
|- bgcolor="#eeffff"
|-
 
 
! bgcolor="#d0e7ff" align="center" |'''Material'''
 
! bgcolor="#d0e7ff" align="center" |'''Material'''
 
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]]
 
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]]

Revision as of 14:04, 3 September 2021

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.


Dry Etching Recipes
RIE Etching ICP Etching Oxygen Plasma Systems Other Dry Etchers
Material RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
Oxford ICP (PlasmaPro 100) ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean
(Gasonics 2000)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)
Ag A
Al A R R A
Au R
Cr A R A A
Cu A
Ge A A
Mo A
Ni R
Pt R
Ru A R A
Si R R A R A
Ta A
Ti R A A
Al2O3 R A
Al2O3 (Sapphire) R A A
AlGaAs R R R A
AlGaN R A
AlN R A
CdZnTe R A
GaAs R R R A R A
GaN R R A R A
GaSb A R A
HfO2 A
InGaAlAs R A R A
InGaAsP R R R A
InP R A A R R R
ITO R A
Photoresist

& ARC

A R R R R A A A A
SiC R A A
SiN R R R A A
SiO2 R R R R R A
SiOxNy A A A
Ta2O5 A A
TiN A
TiO2 A
W-TiW R A A
ZnO2 A
ZnS R A
ZnSe R A
ZrO2 A
Material RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
Oxford ICP (PlasmaPro 100) ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean
(Gasonics 2000)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)