Difference between revisions of "Dry Etching Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(ICP2 AL2O3 R link)
(testing)
Line 2: Line 2:
 
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1"
 
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1"
 
|- bgcolor="#d0e7ff"
 
|- bgcolor="#d0e7ff"
! width="725" height="45" colspan="17" | <div style="font-size: 150%;">Dry Etching Recipes</div>
+
! colspan="17" width="725" height="45" | <div style="font-size: 150%;">Dry Etching Recipes</div>
 
|- bgcolor="#d0e7ff"
 
|- bgcolor="#d0e7ff"
 
| <!-- INTENTIONALLY LEFT BLANK -->
 
| <!-- INTENTIONALLY LEFT BLANK -->
! width="300" height="35" align="center" bgcolor="#d0e7ff" colspan="4" | '''[[RIE Etching Recipes|RIE Etching]]'''
+
! colspan="4" width="300" height="35" align="center" bgcolor="#d0e7ff" | '''[[RIE Etching Recipes|RIE Etching]]'''
 
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]'''
 
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]'''
! align="center" bgcolor="#d0e7ff" colspan="4" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
+
! colspan="4" align="center" bgcolor="#d0e7ff" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
! align="center" bgcolor="#d0e7ff" colspan="3" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]'''
+
! colspan="3" align="center" bgcolor="#d0e7ff" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]'''
 
|-
 
|-
 
! width="65" align="center" bgcolor="#d0e7ff" | '''Material'''
 
! width="65" align="center" bgcolor="#d0e7ff" | '''Material'''
Line 33: Line 33:
 
|
 
|
 
|
 
|
  +
|[https://www.nanotech.ucsb.edu/wiki/index.php/TEST_PAGE?venotify=created TEST]
|
 
 
|
 
|
 
|
 
|

Revision as of 09:31, 6 April 2018

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.
Dry Etching Recipes
RIE Etching ICP Etching Oxygen Plasma Systems Other Dry Etchers
Material RIE 1
(Retired)
RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Si Deep RIE
(PTI/Bosch)
ICP Etch 1
(Panasonic 1)
ICP Etch 2
(Panasonic 2)
ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean
(Gasonics 2000)
UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)
Ag TEST
Al A R R
Au R
Cr A R A
Cu
Ge A
Mo
Ni R
Pt R
Ru
Si R R R
Ta
Ti R A
Al2O3 R
Al2O3 (Sapphire) R A
AlGaAs R R R
AlGaN R
AlN R
CdZnTe R
GaAs R R R R
GaN R R R
GaSb A R
HfO2
InGaAlAs R R
InGaAsP R R
InP R A A R
ITO R
Photoresist

& ARC

A A A R A A
SiC R A
SiN R R R A
SiO2 R R R R
SiOxNy A A
Ta2O5 A
TiN
TiO2
W-TiW R A
ZnO2
ZnS R
ZnSe R
ZrO2
Material RIE 1
(Retired)
RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Si Deep RIE
(PlasmaTherm/Bosch Etch)
ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean
(Gasonics 2000)
UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)