Difference between revisions of "Dry Etching Recipes"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(minor edit)
(link to Oxford InP/PnGaAsP recipes)
 
(15 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 
{{Recipe Table Explanation}}
 
{{Recipe Table Explanation}}
 +
 
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1"
 
{| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1"
 
|- bgcolor="#d0e7ff"
 
|- bgcolor="#d0e7ff"
Line 5: Line 6:
 
|- bgcolor="#d0e7ff"
 
|- bgcolor="#d0e7ff"
 
|<!-- INTENTIONALLY LEFT BLANK -->
 
|<!-- INTENTIONALLY LEFT BLANK -->
! colspan="4" width="300" height="35" align="center" bgcolor="#d0e7ff" |'''[[RIE Etching Recipes|RIE Etching]]'''
+
! colspan="3" |'''[[RIE Etching Recipes|RIE Etching]]'''
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]'''
+
! colspan="6" |'''[[ICP Etching Recipes|ICP Etching]]'''
! colspan="5" align="center" bgcolor="#d0e7ff" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
+
! colspan="5" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]'''
! colspan="3" align="center" bgcolor="#d0e7ff" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]'''
+
! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]'''
 
|-
 
|-
! width="65" align="center" bgcolor="#d0e7ff" |'''Material'''
+
! bgcolor="#d0e7ff" align="center" |'''Material'''
| width="65" bgcolor="#daf1ff" |[[RIE 1 (Custom)|RIE 1<br>(Retired)]]
+
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]]
| width="65" bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> (MRC)]]
+
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]]
| width="65" bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> (MRC)]]
+
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
| width="100" bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br>(PlasmaTherm)]]
+
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
| width="100" bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br>(PlasmaTherm)]]
+
| bgcolor="#daf1ff" |[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]]
| width="100" bgcolor="#daf1ff" |[https://www.nanotech.ucsb.edu/wiki/index.php/ICP_Etching_Recipes#PlasmaTherm.2FSLR_Fluorine_Etcher SLR Fluorine ICP (PlasmaTherm)]
+
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_1_.28Panasonic_E626I.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E626I)</span>]]
| width="120" bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_1_.28Panasonic_E626I.29|ICP Etch 1<br>(Panasonic 1)]]
+
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_2_.28Panasonic_E640.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]]
| width="120" bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_2_.28Panasonic_E640.29|ICP Etch 2<br>(Panasonic 2)]]
+
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]]
| width="85" bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br>(Unaxis VLR)]]
+
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]]
| width="85" bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br>(Technics PEII)]]
+
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]]
| width="95" bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br>(Gasonics 2000)]]
+
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br><span style="font-size: 88%;">(Gasonics 2000)</span>]]
| width="95" bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean (YES EcoClean)]]
+
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]]
| width="85" bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]
+
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]
| width="85" bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br>(EVG 810)]]
+
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br><span style="font-size: 88%;">(EVG 810)</span>]]
| width="85" bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br>(Xetch)]]
+
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br><span style="font-size: 88%;">(Xetch)</span>]]
| width="85" bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br>(uETCH)]]
+
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br><span style="font-size: 88%;">(uETCH)</span>]]
| width="85" bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br>(Oxford)]]
+
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br><span style="font-size: 88%;">(Oxford)</span>]]
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |Ag
+
! bgcolor="#d0e7ff" align="center" |Ag
 
|
 
|
 
|
 
|
Line 47: Line 48:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |Al
+
! bgcolor="#d0e7ff" align="center" |Al
|
 
 
|
 
|
 
|
 
|
Line 57: Line 57:
 
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 2)}}
 
|{{rl|ICP Etching Recipes|Al Etch (Panasonic 2)}}
 +
|
 
|
 
|
 
|
 
|
Line 67: Line 68:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |Au
+
! bgcolor="#d0e7ff" align="center" |Au
 
|
 
|
 
|
 
|
Line 84: Line 85:
 
|
 
|
 
|
 
|
|[https://www.nanotech.ucsb.edu/wiki/index.php/Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29 R]
+
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |Cr
+
! bgcolor="#d0e7ff" align="center" |Cr
|
 
 
|
 
|
 
|
 
|
Line 95: Line 95:
 
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}}
 
|A
 
|A
 +
|
 
|
 
|
 
|
 
|
Line 105: Line 106:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |Cu
+
! bgcolor="#d0e7ff" align="center" |Cu
 
|
 
|
 
|
 
|
Line 123: Line 124:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |Ge
+
! bgcolor="#d0e7ff" align="center" |Ge
 
|
 
|
 
|
 
|
Line 143: Line 144:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |Mo
+
! bgcolor="#d0e7ff" align="center" |Mo
 
|
 
|
 
|
 
|
Line 161: Line 162:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |Ni
+
! bgcolor="#d0e7ff" align="center" |Ni
 
|
 
|
 
|
 
|
Line 180: Line 181:
 
|
 
|
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
|-
+
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |Pt
+
! bgcolor="#d0e7ff" align="center" |Pt
 
|
 
|
 
|
 
|
Line 199: Line 200:
 
|
 
|
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |Ru
+
! bgcolor="#d0e7ff" align="center" |Ru
|
 
 
|
 
|
 
|
 
|
Line 209: Line 209:
 
|A
 
|A
 
|{{Rl|ICP Etching Recipes|Ru (Ruthenium) Etch (Panasonic 2)}}
 
|{{Rl|ICP Etching Recipes|Ru (Ruthenium) Etch (Panasonic 2)}}
 +
|
 
|
 
|
 
|
 
|
Line 219: Line 220:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |Si
+
! bgcolor="#d0e7ff" align="center" |Si
|
 
 
|
 
|
 
|
 
|
Line 228: Line 228:
 
|
 
|
 
|
 
|
 +
|A
 
|
 
|
 
|
 
|
Line 237: Line 238:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |Ta
+
! bgcolor="#d0e7ff" align="center" |Ta
 
|
 
|
 
|
 
|
Line 256: Line 257:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |Ti
+
! bgcolor="#d0e7ff" align="center" |Ti
|
 
 
|
 
|
 
|
 
|
Line 266: Line 266:
 
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}}
 
|A
 
|A
 +
|
 
|
 
|
 
|
 
|
Line 275: Line 276:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |Al<sub>2</sub>O<sub>3</sub>
+
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub>
 
|
 
|
 
|
 
|
Line 283: Line 284:
 
|
 
|
 
|
 
|
 +
|[https://wiki.nanotech.ucsb.edu/w/index.php?title=ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R]
 
|
 
|
|[https://www.nanotech.ucsb.edu/wiki/index.php/ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R]
 
 
|
 
|
 
|
 
|
Line 295: Line 296:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub>
+
! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub>
|
 
 
|
 
|
 
|
 
|
Line 304: Line 304:
 
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}}
 
|A
 
|A
 +
|
 
|
 
|
 
|
 
|
Line 313: Line 314:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |AlGaAs
+
! bgcolor="#d0e7ff" align="center" |AlGaAs
|
 
 
|
 
|
 
|
 
|
Line 323: Line 323:
 
|{{rl|ICP Etching Recipes|AlGaAs Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|AlGaAs Etch (Panasonic 1)}}
 
|
 
|
 +
|A
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}}
 
|
 
|
Line 333: Line 334:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |AlGaN
+
! bgcolor="#d0e7ff" align="center" |AlGaN
|
 
 
|
 
|
 
|
 
|
Line 342: Line 342:
 
|
 
|
 
|
 
|
 +
|A
 
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
 
|
 
|
Line 351: Line 352:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |AlN
+
! bgcolor="#d0e7ff" align="center" |AlN
 
|
 
|
 
|
 
|
Line 371: Line 372:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |CdZnTe
+
! bgcolor="#d0e7ff" align="center" |CdZnTe
 +
|{{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}}
 
|
 
|
|{{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}}
 
 
|
 
|
 
|
 
|
Line 389: Line 390:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |GaAs
+
! bgcolor="#d0e7ff" align="center" |GaAs
|
 
 
|
 
|
 
|
 
|
Line 399: Line 399:
 
|{{rl|ICP Etching Recipes|GaAs-AlGaAs_Etch_.28Panasonic_1.29}}
 
|{{rl|ICP Etching Recipes|GaAs-AlGaAs_Etch_.28Panasonic_1.29}}
 
|{{rl|ICP Etching Recipes|GaAs Etch (Panasonic 2)}}
 
|{{rl|ICP Etching Recipes|GaAs Etch (Panasonic 2)}}
 +
|A
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}}
 
|
 
|
Line 408: Line 409:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |GaN
+
! bgcolor="#d0e7ff" align="center" |GaN
|
 
 
|
 
|
 
|
 
|
Line 418: Line 418:
 
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}}
 
|
 
|
 +
|A
 
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}}
 
|
 
|
Line 427: Line 428:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |GaSb
+
! bgcolor="#d0e7ff" align="center" |GaSb
 
|
 
|
 
|
 
|
Line 435: Line 436:
 
|
 
|
 
|
 
|
 +
|A
 
|
 
|
|A
 
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}}
 
|
 
|
Line 447: Line 448:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |HfO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub>
 
|
 
|
 
|
 
|
Line 465: Line 466:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |InGaAlAs
+
! bgcolor="#d0e7ff" align="center" |InGaAlAs
|
 
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
 
|
 
|
Line 475: Line 475:
 
|
 
|
 
|
 
|
 +
|A
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
 
|
 
|
Line 484: Line 485:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |InGaAsP
+
! bgcolor="#d0e7ff" align="center" |InGaAsP
|
 
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
 
|
 
|
Line 494: Line 494:
 
|
 
|
 
|
 
|
 +
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]]
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
 
|
 
|
Line 503: Line 504:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |InP
+
! bgcolor="#d0e7ff" align="center" |InP
|
 
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
 
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}}
 
|
 
|
Line 513: Line 513:
 
|A
 
|A
 
|A
 
|A
 +
|[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]]
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
 
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}}
 
|
 
|
Line 521: Line 522:
 
|
 
|
 
|
 
|
|A
+
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}}
|-
+
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |ITO
+
! bgcolor="#d0e7ff" align="center" |ITO
 +
|{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}}
 
|
 
|
|{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}}
 
 
|
 
|
 
|
 
|
Line 541: Line 542:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
 
!Photoresist
 
!Photoresist
 
& ARC
 
& ARC
|
 
 
|
 
|
 
|A
 
|A
|[https://www.nanotech.ucsb.edu/wiki/index.php/RIE_Etching_Recipes#Photoresist_and_ARC R]
+
|[https://wiki.nanotech.ucsb.edu/wiki/RIE_Etching_Recipes#Photoresist_and_ARC_.28RIE_5.29 R]
 
|
 
|
 +
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_.26_ARC_.28Fluorine_ICP_Etcher.29 R]
 +
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R]
 +
|[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_etching_.28Panasonic_2.29 R]
 
|
 
|
|[https://www.nanotech.ucsb.edu/wiki/index.php/ICP_Etching_Recipes#Photoresist_and_ARC_Etching R]
 
|[https://www.nanotech.ucsb.edu/wiki/index.php/ICP_Etching_Recipes#Photoresist_and_ARC_etching_2 R]
 
 
|
 
|
 
|A
 
|A
Line 561: Line 562:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |SiC
+
! bgcolor="#d0e7ff" align="center" |SiC
|
 
 
|
 
|
 
|
 
|
Line 571: Line 571:
 
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}}
 
|A
 
|A
 +
|
 
|
 
|
 
|
 
|
Line 580: Line 581:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |SiN
+
! bgcolor="#d0e7ff" align="center" |SiN
|
 
 
|
 
|
 
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiN<sub>x</sub> Etching (RIE 3)}}
 
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiN<sub>x</sub> Etching (RIE 3)}}
 
|
 
|
 
|
 
|
|
+
|A
 
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 2)}}
 
|{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 2)}}
 +
|
 
|
 
|
 
|A
 
|A
Line 600: Line 601:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |SiO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub>
|
 
 
|
 
|
 
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiO<sub>2</sub> Etching (RIE 3)}}
 
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiO<sub>2</sub> Etching (RIE 3)}}
 
|
 
|
 
|
 
|
|A
+
|{{rl|ICP Etching Recipes|SiO2 Etching (Fluorine ICP Etcher)}}
 
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 2)}}
 
|{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 2)}}
 +
|
 
|
 
|
 
|
 
|
Line 618: Line 619:
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}}
 
|{{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}}
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |SiOxNy
+
! bgcolor="#d0e7ff" align="center" |SiOxNy
|
 
 
|
 
|
 
|
 
|
Line 628: Line 628:
 
|A
 
|A
 
|A
 
|A
 +
|
 
|
 
|
 
|
 
|
Line 637: Line 638:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |Ta<sub>2</sub>O<sub>5</sub>
+
! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub>
 
|
 
|
 
|
 
|
Line 645: Line 646:
 
|
 
|
 
|
 
|
 +
|[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 A]
 
|
 
|
|[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 A]
 
 
|
 
|
 
|
 
|
Line 656: Line 657:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |TiN
+
! bgcolor="#d0e7ff" align="center" |TiN
 
|
 
|
 
|
 
|
Line 676: Line 677:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |TiO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub>
 
|
 
|
 
|
 
|
Line 694: Line 695:
 
|
 
|
 
|A
 
|A
|- bgcolor="#eeffff"
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |W-TiW
+
! bgcolor="#d0e7ff" align="center" |W-TiW
|
 
 
|
 
|
 
|
 
|
Line 704: Line 704:
 
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}}
 
|{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}}
 
|A
 
|A
 +
|
 
|
 
|
 
|
 
|
Line 714: Line 715:
 
|A
 
|A
 
|- bgcolor="#eeffff"
 
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |ZnO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub>
 
|
 
|
 
|
 
|
Line 732: Line 733:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |ZnS
+
! bgcolor="#d0e7ff" align="center" |ZnS
 +
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
 
|
 
|
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
 
 
|
 
|
 
|
 
|
Line 751: Line 752:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |ZnSe
+
! bgcolor="#d0e7ff" align="center" |ZnSe
 +
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
 
|
 
|
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}}
 
 
|
 
|
 
|
 
|
Line 770: Line 771:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#ffffff"
! align="center" bgcolor="#d0e7ff" |ZrO<sub>2</sub>
+
! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub>
 
|
 
|
 
|
 
|
Line 789: Line 790:
 
|
 
|
 
|A
 
|A
|-
+
|- bgcolor="#eeffff"
! align="center" bgcolor="#d0e7ff" |'''Material'''
+
! bgcolor="#d0e7ff" align="center" |'''Material'''
| bgcolor="#daf1ff" |[[RIE 1 (Custom)|RIE 1<br>(Retired)]]
+
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]]
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> (MRC)]]
+
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]]
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> (MRC)]]
+
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br>(PlasmaTherm)]]
+
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]]
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br>(PlasmaTherm)]]
+
| bgcolor="#daf1ff" |[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]]
| bgcolor="#daf1ff" |[[Fluorine ICP Etcher (PlasmaTherm/SLR Fluorine ICP)|SLR Fluorine ICP (PlasmaTherm)]]
+
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_1_.28Panasonic_E626I.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E626I)</span>]]
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_1_.28Panasonic_E626I.29|ICP Etch 1<br>(Panasonic E626I)]]
+
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_2_.28Panasonic_E640.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]]
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_2_.28Panasonic_E640.29|ICP Etch 2<br>(Panasonic E640)]]
+
| bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]]
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br>(Unaxis VLR)]]
+
| bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]]
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br>(Technics PEII)]]
+
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]]
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br>(Gasonics 2000)]]
+
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br><span style="font-size: 88%;">(Gasonics 2000)</span>]]
| width="95" bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean (YES EcoClean)]]
+
| bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]
 
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]]
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br>(EVG 810)]]
+
| bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br><span style="font-size: 88%;">(EVG 810)</span>]]
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br>(Xetch)]]
+
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br><span style="font-size: 88%;">(Xetch)</span>]]
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br>(uETCH)]]
+
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br><span style="font-size: 88%;">(uETCH)</span>]]
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br>(Oxford)]]
+
| bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br><span style="font-size: 88%;">(Oxford)</span>]]
 
|}
 
|}
  
 
[[Category:Processing]]
 
[[Category:Processing]]

Latest revision as of 13:53, 8 October 2021

  • R = Recipe is available. Clicking this link will take you to the recipe.
  • A = Material is available for use, but no recipes are provided.
Dry Etching Recipes
RIE Etching ICP Etching Oxygen Plasma Systems Other Dry Etchers
Material RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
Oxford ICP (PlasmaPro 100) ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean
(Gasonics 2000)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)
Ag A
Al A R R A
Au R
Cr A R A A
Cu A
Ge A A
Mo A
Ni R
Pt R
Ru A R A
Si R R A R A
Ta A
Ti R A A
Al2O3 R A
Al2O3 (Sapphire) R A A
AlGaAs R R A R A
AlGaN A R A
AlN R A
CdZnTe R A
GaAs R R R A R A
GaN R R A R A
GaSb A R A
HfO2 A
InGaAlAs R A R A
InGaAsP R R R A
InP R A A R R R
ITO R A
Photoresist

& ARC

A R R R R A A A A
SiC R A A
SiN R A R R A A
SiO2 R R R R R A
SiOxNy A A A
Ta2O5 A A
TiN A
TiO2 A
W-TiW R A A
ZnO2 A
ZnS R A
ZnSe R A
ZrO2 A
Material RIE 2
(MRC)
RIE 3
(MRC)
RIE 5
(PlasmaTherm)
DSEIII
(PlasmaTherm)
Fluorine ICP (PlasmaTherm) ICP Etch 1
(Panasonic E626I)
ICP Etch 2
(Panasonic E640)
Oxford ICP (PlasmaPro 100) ICP-Etch
(Unaxis VLR)
Ashers
(Technics PEII)
Plasma Clean
(Gasonics 2000)
Plasma Clean (YES EcoClean) UV Ozone Reactor Plasma Activation
(EVG 810)
XeF2 Etch
(Xetch)
Vapor HF Etch
(uETCH)
CAIBE
(Oxford)