Difference between revisions of "Dry Etching Recipes"
Jump to navigation
Jump to search
m (corrected links) |
|||
(68 intermediate revisions by 5 users not shown) | |||
Line 1: | Line 1: | ||
+ | ===<u>[[Process Group - Process Control Data#Etching .28Process Control Data.29|Process Control Data]]</u>=== |
||
− | {{Recipe Table Explanation}} |
||
+ | <small>''See [[Process Group - Process Control Data#Etching .28Process Control Data.29|linked page]] for [https://en.wikipedia.org/wiki/Statistical_process_control process control data] (dep rate/stress etc. over time), for a selection of often-used thin-film depositions.''</small> |
||
− | {| border="1" class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" |
||
+ | |||
− | |- bgcolor="#D0E7FF" |
||
+ | ===Dry Etching Tools/Materials Table=== |
||
− | ! width="725" height="45" colspan="16" | <div style="font-size: 150%;">Dry Etching Recipes</div> |
||
+ | |||
− | |- bgcolor="#D0E7FF" |
||
+ | *<small>'''R''': ''Recipe is available. Clicking this link will take you to the recipe.''</small> |
||
− | | <!-- INTENTIONALLY LEFT BLANK --> |
||
+ | *<small>'''A''': ''Material is available for use, but no recipes are provided.''</small> |
||
− | ! width="300" bgcolor="#D0E7FF" align="center" height="35" colspan="4" | '''[[RIE Etching Recipes|RIE Etching]]''' |
||
+ | |||
− | ! width="300" bgcolor="#D0E7FF" align="center" colspan="4" | '''[[ICP Etching Recipes|ICP Etching]]''' |
||
+ | {| class="wikitable" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center; font-size: 95%" border="1" |
||
− | ! bgcolor="#D0E7FF" align="center" colspan="4"|'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
||
+ | |- |
||
− | ! bgcolor="#D0E7FF" align="center" colspan="3" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
||
+ | ! colspan="17" width="725" height="45" |<div style="font-size: 150%;">Dry Etching Recipes</div> |
||
− | |- |
||
+ | |- bgcolor="#d0e7ff" |
||
− | ! width="65" bgcolor="#D0E7FF" align="center" | '''Material''' |
||
− | | |
+ | | bgcolor="#eaecf0" |<!-- INTENTIONALLY LEFT BLANK --> |
+ | ! colspan="3" |'''[[RIE Etching Recipes|RIE Etching]]''' |
||
− | | width="65" bgcolor="#DAF1FF" | [[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> (MRC)]] |
||
+ | ! colspan="6" |'''[[ICP Etching Recipes|ICP Etching]]''' |
||
− | | width="65" bgcolor="#DAF1FF" | [[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> (MRC)]] |
||
+ | ! colspan="4" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
||
− | | width="100" bgcolor="#DAF1FF" | [[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br>(PlasmaTherm)]] |
||
+ | ! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
||
− | | width="100" bgcolor="#DAF1FF" | [[ICP_Etching_Recipes#Si_Deep_RIE_.28PlasmaTherm.2FBosch_Etch.29|Si Deep RIE<br>(PTI/Bosch)]] |
||
+ | |- bgcolor="#d0e7ff" |
||
− | | width="120" bgcolor="#DAF1FF" | [[ICP_Etching_Recipes#ICP_Etch_1_.28Panasonic_E626I.29|ICP Etch 1<br>(Panasonic 1)]] |
||
+ | ! bgcolor="#d0e7ff" align="center" |'''Material''' |
||
− | | width="120" bgcolor="#DAF1FF" | [[ICP_Etching_Recipes#ICP_Etch_2_.28Panasonic_E640.29|ICP Etch 2<br>(Panasonic 2)]] |
||
− | | |
+ | | bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
+ | | bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
− | | width="85" bgcolor="#DAF1FF" | [[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br>(Technics PEII)]] |
||
+ | | bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
− | | width="95" bgcolor="#DAF1FF" | [[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br>(Gasonics 2000)]] |
||
+ | | bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
− | | width="85" bgcolor="#DAF1FF" | [[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
||
+ | | bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
− | | width="85" bgcolor="#DAF1FF" | [[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br>(EVG 810)]] |
||
− | | |
+ | | bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 1 .28Panasonic E646V.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E646V)</span>]] |
− | | |
+ | | bgcolor="#daf1ff" |[[ICP Etching Recipes#ICP Etch 2 .28Panasonic E626I.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
+ | | bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
||
− | | width="85" bgcolor="#DAF1FF" | [[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br>(Oxford)]] |
||
+ | | bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]] |
||
− | |-bgcolor ="#EEFFFF" |
||
+ | | bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
||
− | ! bgcolor="#D0E7FF" align="center" | Al |
||
+ | | bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
||
− | | |
||
+ | | bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
||
− | | |
||
+ | | bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br><span style="font-size: 88%;">(EVG 810)</span>]] |
||
− | | |
||
+ | | bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br><span style="font-size: 88%;">(Xetch)</span>]] |
||
− | | [[RIE Etching Recipes|A]] |
||
+ | | bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br><span style="font-size: 88%;">(uETCH)</span>]] |
||
− | | |
||
+ | | bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br><span style="font-size: 88%;">(Oxford)</span>]] |
||
− | | {{rl|ICP Etching Recipes|Al Etch(Panasonic 1)}} |
||
+ | |- bgcolor="#eeffff" |
||
− | | {{rl|ICP Etching Recipes|Al Etch(Panasonic 2)}} |
||
+ | ! bgcolor="#d0e7ff" align="center" |Ag |
||
− | | |
||
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Al |
||
+ | | |
||
+ | | |
||
+ | |[[RIE Etching Recipes|A]] |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|Al Etch (Panasonic 1)}} |
||
+ | |{{rl|ICP Etching Recipes|Al Etch (Panasonic 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Au |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
| |
| |
||
− | | |
||
− | | |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | Ti |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|Ti Etch(Panasonic 1)}} |
||
− | | A |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | Cr |
||
− | | |
||
− | | |
||
− | | |
||
− | | A |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|Cr Etch(Panasonic 1)}} |
||
− | | A |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | Ge |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | Ag |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | Pt |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | |{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | Au |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Cr |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|Cr Etch (Panasonic 1)}} |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Cu |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Ge |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Mo |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
|- |
|- |
||
+ | !Nb |
||
− | ! bgcolor="#D0E7FF" align="center" | Ni |
||
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | |A |
− | | |
+ | |A |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
+ | | |
||
+ | | |
||
+ | | |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Ni |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
| |
| |
||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
|- |
|- |
||
+ | !Os |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | Cu |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | Ru |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | Mo |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
+ | |A |
||
+ | |A |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | Ta |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | W-TiW |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|W-TiW Etch(Panasonic 1)}} |
||
− | | A |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | Al<sub>2</sub>O<sub>3</sub> |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | HfO<sub>2</sub> |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
+ | |- bgcolor="#eeffff" |
||
− | |- |
||
− | ! bgcolor="# |
+ | ! bgcolor="#d0e7ff" align="center" |Pt |
− | | |
||
− | | {{rl|RIE Etching Recipes|ITO Etch (RIE 2)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | | |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | SiO<sub>2</sub> |
||
− | | |
||
− | | |
||
− | | {{rl|RIE Etching Recipes| (RIE 3)}} |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|SIO2Etch(Panasonic 1)}} |
||
− | | {{rl|ICP Etching Recipes|SIO2Etch(Panasonic 2)}} |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | | {{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}} |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | SiN |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|SINxEtch(Panasonic 1)}} |
||
− | | {{rl|ICP Etching Recipes|SINxEtch(Panasonic 2)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | SiOxNy |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | Ta<sub>2</sub>O<sub>5</sub> |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | TiO<sub>2</sub> |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | TiN |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
+ | |{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
− | |-bgcolor ="#EEFFFF" |
||
− | + | |- bgcolor="#ffffff" |
|
+ | ! bgcolor="#d0e7ff" align="center" |Ru |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |{{Rl|ICP Etching Recipes|Ru (Ruthenium) Etch (Panasonic 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Si |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|DSEIII_(PlasmaTherm/Deep_Silicon_Etcher)}} |
||
+ | |{{Rl|ICP Etching Recipes|Si_Etching_.28Fluorine_ICP_Etcher.29}} |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |{{rl|Other Dry Etching Recipes|Other Dry Etch (XeF2 Etcher)}} |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Ta |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Ti |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|Ti Etch (Panasonic 1)}} |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |[https://wiki.nanotech.ucsb.edu/w/index.php?title=ICP_Etching_Recipes#Al2O3_Etching_.28Panasonic_2.29 R] |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|Sapphire Etch (Panasonic 1)}} |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |AlGaAs |
||
+ | | |
||
+ | | |
||
+ | |{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}} |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
||
+ | | |
||
+ | |[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]] |
||
+ | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |AlGaN |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]] |
||
+ | |{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |AlN |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
|- |
|- |
||
+ | !BCB |
||
− | ! bgcolor="#D0E7FF" align="center" | ZrO<sub>2</sub> |
||
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | |A |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
− | | |
+ | | |
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |CdZnTe |
||
+ | |{{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |GaAs |
||
+ | | |
||
+ | | |
||
+ | |{{rl|RIE Etching Recipes|AlGaAs\GaAs Etching (RIE 5)}} |
||
| |
| |
||
− | | |
||
| |
| |
||
+ | |{{rl|ICP Etching Recipes|GaAs-AlGaAs Etch (Panasonic 1)}} |
||
− | |-bgcolor ="#EEFFFF" |
||
+ | |{{rl|ICP Etching Recipes|GaAs Etch (Panasonic 2)}} |
||
− | ! bgcolor="#D0E7FF" align="center" | GaAs |
||
+ | |[[ICP Etching Recipes#GaAs Etch .28Oxford ICP Etcher.29|R]] |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|RIE Etching Recipes|AlGaAs Etch (RIE 5)}} |
||
− | | |
||
− | |{{rl|ICP Etching Recipes|AlGaAs Etch (Panasonic 1)}} |
||
− | |{{rl|ICP Etching Recipes|GaAs Etch (Panasonic 2)}} |
||
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}} |
|{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|GaAs Etch (Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | AlGaAs |
||
− | | |
||
− | | |
||
− | | |
||
− | |{{rl|RIE Etching Recipes|AlGaAs Etch (RIE 5)}} |
||
− | | |
||
− | |{{rl|ICP Etching Recipes|AlGaAs Etch (Panasonic 1)}} |
||
− | | |
||
− | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaAs-AlGaAs Etch (Unaxis VLR)|AlGaAs Etch (Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | | |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | InGaAlAs |
||
− | | |
||
− | | {{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | | |
+ | |A |
− | + | |- bgcolor="#eeffff" |
|
+ | ! bgcolor="#d0e7ff" align="center" |GaN |
||
− | | |
||
− | | {{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
+ | |{{rl|RIE Etching Recipes|GaN Etching (RIE 5)}} |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | InP |
||
− | | |
||
− | | {{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
+ | |{{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
||
− | |- |
||
+ | |A |
||
− | ! bgcolor="#D0E7FF" align="center" | GaN |
||
+ | |[[ICP Etching Recipes#GaN Etch .28Oxford ICP Etcher.29|R]] |
||
− | | |
||
+ | |{{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | |{{rl|RIE Etching Recipes|RIE 5 (PlasmaTherm)|GaN Etch (RIE 5)}} |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|GaN Etch (Panasonic 1)}} |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | AlGaN |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | AlN |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|GaN Etch (Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | | |
+ | |A |
− | |- |
+ | |- bgcolor="#ffffff" |
+ | ! bgcolor="#d0e7ff" align="center" |GaSb |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | GaSb |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | | |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | CdZnTe |
||
− | | |
||
− | | {{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
− | | |
||
− | |- |
||
− | ! bgcolor="#D0E7FF" align="center" | ZnS |
||
− | | |
||
− | | {{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
+ | |A |
+ | |A |
||
+ | |A |
||
+ | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|GaSb Etch Unaxis VLR)}} |
||
| |
| |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |InGaAlAs |
||
+ | |{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |InGaAsP |
||
+ | |{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]] |
||
+ | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |InP |
||
+ | |{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |A |
||
+ | |[[ICP Etching Recipes#InP Ridge Etch .28Oxford ICP Etcher.29|R]] |
||
+ | |{{rl|ICP Etching Recipes|ICP-Etch (Unaxis VLR)|InP-InGaAs-InAlAs Etch (Unaxis VLR)|InP Etch (Unaxis VLR)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |ITO |
||
+ | |{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
|- |
|- |
||
+ | !LiNbO3 |
||
− | ! bgcolor="#D0E7FF" align="center" | ZnSe |
||
− | | |
||
− | | {{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | Si |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|Si Etch (PlasmaTherm/Bosch Etch)}} |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|Other Dry Etching Recipes|Other Dry Etch (XeF2 Etcher)}} |
||
| |
| |
||
| |
| |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | !Photoresist |
||
+ | & ARC |
||
+ | | |
||
+ | |A |
||
+ | |[https://wiki.nanotech.ucsb.edu/wiki/RIE_Etching_Recipes#Photoresist_and_ARC_.28RIE_5.29 R] |
||
+ | | |
||
+ | |[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_.26_ARC_.28Fluorine_ICP_Etcher.29 R] |
||
+ | |[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_Etching_.28Panasonic_1.29 R] |
||
+ | |[https://wiki.nanotech.ucsb.edu/wiki/ICP_Etching_Recipes#Photoresist_and_ARC_etching_.28Panasonic_2.29 R] |
||
+ | | |
||
+ | | |
||
+ | |[[Oxygen Plasma System Recipes#O2 Ashing|R]] |
||
+ | |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|R]] |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
|- |
|- |
||
+ | !Ru |
||
− | ! bgcolor="#D0E7FF" align="center" | SiC |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|SiC Etch(Panasonic 1)}} |
||
− | | A |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
− | | |
||
| |
| |
||
− | |-bgcolor ="#EEFFFF" |
||
− | ! bgcolor="#D0E7FF" align="center" | Sapphire |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | {{rl|ICP Etching Recipes|Sapphire Etch(Panasonic 1)}} |
||
− | | A |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
− | | |
||
| |
| |
||
| |
| |
||
| |
| |
||
+ | |A |
||
+ | |[[ICP Etching Recipes#Ru .28Ruthenium.29 Etch .28Panasonic 2.29|R]] |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |SiC |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|SiC Etch (Panasonic 1)}} |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |SiN |
||
+ | | |
||
+ | |{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiN<sub>x</sub> Etching (RIE 3)}} |
||
+ | | |
||
+ | | |
||
+ | |[[ICP Etching Recipes#Si3N4 Etching .28Fluorine ICP Etcher.29|R]] |
||
+ | |{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 1)}} |
||
+ | |{{rl|ICP Etching Recipes|SiNx Etching (Panasonic 2)}} |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
||
+ | | |
||
+ | |{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiO<sub>2</sub> Etching (RIE 3)}} |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|SiO2 Etching (Fluorine ICP Etcher)}} |
||
+ | |{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 1)}} |
||
+ | |{{rl|ICP Etching Recipes|SiO2 Etching (Panasonic 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |{{rl|Other Dry Etching Recipes|Other Dry Etch (Vapor HF Etcher)}} |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |SiOxNy |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
|- |
|- |
||
+ | !SU8 |
||
− | ! bgcolor="#D0E7FF" align="center" | '''Material''' |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[RIE 1 (Custom)|RIE 1<br>(Retired)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> (MRC)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> (MRC)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br>(PlasmaTherm)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[ICP_Etching_Recipes#Si_Deep_RIE_.28PlasmaTherm.2FBosch_Etch.29|Si Deep RIE<br>(PlasmaTherm/Bosch Etch)]] |
||
+ | |A |
||
− | | bgcolor="#DAF1FF" | [[ICP_Etching_Recipes#ICP_Etch_1_.28Panasonic_E626I.29|ICP Etch 1<br>(Panasonic E626I)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[ICP_Etching_Recipes#ICP_Etch_2_.28Panasonic_E640.29|ICP Etch 2<br>(Panasonic E640)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br>(Unaxis VLR)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br>(Technics PEII)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[Oxygen_Plasma_System_Recipes#Plasma_Clean_.28Gasonics_2000.29|Plasma Clean<br>(Gasonics 2000)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br>(EVG 810)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br>(Xetch)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br>(uETCH)]] |
||
+ | | |
||
− | | bgcolor="#DAF1FF" | [[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br>(Oxford)]] |
||
+ | | |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |[https://www.osapublishing.org/optica/abstract.cfm?uri=optica-4-5-532 A] |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |TiN |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |W-TiW |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |{{rl|ICP Etching Recipes|W-TiW Etch (Panasonic 1)}} |
||
+ | |A |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |ZnS |
||
+ | |{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |ZnSe |
||
+ | |{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}} |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#ffffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |A |
||
+ | |- bgcolor="#eeffff" |
||
+ | ! bgcolor="#d0e7ff" align="center" |'''Material''' |
||
+ | | bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> <span style="font-size: 88%;">(MRC)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_5_.28PlasmaTherm.29|RIE 5<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[ICP_Etching_Recipes#DSEIII_.28PlasmaTherm.2FDeep_Silicon_Etcher.29|DSEIII<br><span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[ICP Etching Recipes#PlasmaTherm.2FSLR Fluorine Etcher|Fluorine ICP <span style="font-size: 88%;">(PlasmaTherm)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_1_.28Panasonic_E626I.29|ICP Etch 1<br><span style="font-size: 88%;">(Panasonic E626I)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP_Etch_2_.28Panasonic_E640.29|ICP Etch 2<br><span style="font-size: 88%;">(Panasonic E640)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[ICP Etching Recipes#Oxford ICP Etcher .28PlasmaPro 100 Cobra.29|Oxford ICP <span style="font-size: 88%;">(PlasmaPro 100)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[ICP_Etching_Recipes#ICP-Etch_.28Unaxis_VLR.29|ICP-Etch<br><span style="font-size: 88%;">(Unaxis VLR)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Ashers_.28Technics_PEII.29|Ashers<br><span style="font-size: 88%;">(Technics PEII)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[Oxygen Plasma System Recipes#Plasma Clean .28YES EcoClean.29|Plasma Clean <span style="font-size: 88%;">(YES EcoClean)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#UV_Ozone_Reactor|UV Ozone Reactor]] |
||
+ | | bgcolor="#daf1ff" |[[Oxygen_Plasma_System_Recipes#Plasma_Activation_.28EVG_810.29|Plasma Activation<br><span style="font-size: 88%;">(EVG 810)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#XeF2_Etch_.28Xetch.29|XeF2 Etch<br><span style="font-size: 88%;">(Xetch)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#Vapor_HF_Etch_.28uETCH.29|Vapor HF Etch<br><span style="font-size: 88%;">(uETCH)</span>]] |
||
+ | | bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br><span style="font-size: 88%;">(Oxford)</span>]] |
||
|} |
|} |
||
Latest revision as of 15:31, 7 February 2024
Process Control Data
See linked page for process control data (dep rate/stress etc. over time), for a selection of often-used thin-film depositions.
Dry Etching Tools/Materials Table
- R: Recipe is available. Clicking this link will take you to the recipe.
- A: Material is available for use, but no recipes are provided.